Tear osmolarity measurement using the TearLab™ Osmolarity System in the assessment of dry eye treatment effectiveness

被引:121
|
作者
Benelli, Umberto [1 ]
Nardi, Marco [1 ]
Posarelli, Chiara [1 ]
Albert, Timothy G. [1 ]
机构
[1] Univ Pisa, Dept Neurosci, Sect Ophthalmol, I-56126 Pisa, Pi, Italy
来源
CONTACT LENS & ANTERIOR EYE | 2010年 / 33卷 / 02期
关键词
Lubricant eye drop; Tear osmolarity; Dry eye; ARTIFICIAL TEARS; INSTILLATION; FORMULATIONS;
D O I
10.1016/j.clae.2010.01.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the efficacy of three commercially available lubricant eye drops for the treatment of mild, dry, irritated eyes. Methods: Randomized, investigator-masked evaluation of 60 patients in which 20 patients used carboxymethylcellulose sodium (CMC), 0.5% (Cellufresh (R), Allergan Inc., Irvine, CA) (group 1); 20 patients used a drop containing polyethylene glycol 400, 2.5% and sodium hyaluronate (Blink (R) Tears, Abbott Medical Optics Inc., Santa Ana, CA) (group 2); and 20 patients used HP Guar 0.18% (Systane (R), Alcon Laboratories Inc., Ft. Worth, TX) (group 3). Study visits were at baseline and 1 month. Tests performed at both visits included Schirmer, tear-film break-up time (TBUT), visual acuity, fluorescein staining, tear osmolarity and wavefront aberrometry. Osmolarity testing was performed prior to instillation of the lubricant eye drops and then a final time 5 min after instillation of the drop at both day 1 and day 30. Tear osmolarity was performed only in the right eye and only one time before and after instillation of lubricant eye drops. Results: At day 1 the mean reduction in osmolarity 5 min after instillation of the lubricant eye drop was, -5.0 +/- 1.9 in group 1, -9.0 +/- 4.2 in group 2 and -5.0 +/- 2.2 in group 3. At day 30 the mean reduction in osmolarity 5 min after instillation of the lubricant eye drop was, -5.6 +/- 2.3 mOsm/L in group 1; -9.9 +/- 2.8 mOsm/L in group 2 and -4.5 +/- 1.8 mOsm/L in group 3. The differences were statistically significant between groups 1 and 2, and 2 and 3. There was a reduction of osmolarity from day 1 to day 30 but the differences were not statistically significant. We feel that after a 30-day treatment with the lubricant eye drops, the lower osmolarity values could indicate that the tear film is progressing towards a more normal osmolarity value. A future study could examine the tear osmolarity value after 60 or 90 days of usage. LogMAR best-corrected visual acuity (BCVA) results showed an improvement in group 2 compared with baseline with no change in BCVA in groups 1 and 3. There was no statistically significant change from day 1 to 1 month in TBUT, while the Schirmer test showed an improvement in all groups at 1 month. Conclusions: Assessment of tear osmolarity provides the most objective, measurable test for determining improvement in dry eye patients. The instillation of any artificial tear or lubricant eye drop should decrease the tear-film osmolarity. The results found that polyethylene glycol 400,0.25% and sodium hyaluronate (Blink (R) Intensive Tears) significantly improved tear osmolarity compared with carboxymethylcellulose sodium (CMC), 0.5% (Cellufresh (R)) and HP Guar 0.18% (Systane (R)) after instillation. (C) 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [21] Collecting tear osmolarity measurements in the diagnosis of dry eye
    Srinivasan, Sruthi
    Nichols, Kelly K.
    EXPERT REVIEW OF OPHTHALMOLOGY, 2009, 4 (05) : 451 - 453
  • [22] Tear Osmolarity as a Biomarker for Dry Eye Disease Severity
    Suzuki, Mari
    Massingale, Morgan L.
    Ye, Fen
    Godbold, James
    Elfassy, Tali
    Vallabhajosyula, Maithreyi
    Asbell, Penny A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (09) : 4557 - 4561
  • [23] Assessment of tear film osmolarity using the TearLab™ osmometer in normal dogs and dogs with keratoconjunctivitis sicca
    Sebbag, Lionel
    Park, Shin Ae
    Kass, Philip H.
    Maggs, David J.
    Attar, Mayssa
    Murphy, Christopher J.
    VETERINARY OPHTHALMOLOGY, 2017, 20 (04) : 357 - 364
  • [24] Evaluation of Tear Film Osmolarity Among Diabetic Patients Using a TearLab Osmometer
    Abusharha, Ali
    Alsaqar, Ali
    Fagehi, Raied
    Alobaid, Mohammad
    Almayouf, Ali
    Alajlan, Sulaiman
    Omair, Mossab
    Alahmad, Essa
    Masmali, Ali
    CLINICAL OPTOMETRY, 2021, 13 : 257 - 261
  • [25] Evaluation of tear film osmolarity using Tearlab® and I-Pen® osmometry
    Messmer, Elisabeth M.
    Schaumberger, Markus M.
    Priglinger, Siegfried
    Koenig, Susanna F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [26] Tear film osmolarity: Determination of a referent for dry eye diagnosis
    Tomlinson, Alan
    Khanal, Santosh
    Ramaesh, Kanna
    Diaper, Charles
    McFadyen, Angus
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (10) : 4309 - 4315
  • [27] Tear Osmolarity in the Diagnosis of Systemic Dehydration and Dry Eye Disease
    Bron, Anthony J.
    Willshire, Catherine
    DIAGNOSTICS, 2021, 11 (03)
  • [28] Tear film osmolarity and dry eye disease: a review of the literature
    Potvin, Richard
    Makari, Sarah
    Rapuano, Christopher J.
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 2039 - 2047
  • [29] Tear osmolarity and subjective dry eye symptoms in migraine sufferers
    Wong, Melody
    Dodd, Mary-Magdalene
    Masiowski, Paul
    Sharma, Vikas
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2017, 52 (05): : 513 - 518
  • [30] Tear osmolarity, dry eye syndrome, blepharospasm and botulinum neurotoxin
    Girard, B.
    Sauveur, G. de Saint
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2021, 44 (10): : 1553 - 1559