Field calibration of a cluster of low-cost commercially available sensors for air quality monitoring. Part B: NO, CO and CO2

被引:231
|
作者
Spinelle, Laurent [1 ]
Gerboles, Michel [1 ]
Villani, Maria Gabriella [2 ]
Aleixandre, Manuel [3 ]
Bonavitacola, Fausto [4 ]
机构
[1] European Commiss, Joint Res Ctr, Directorate Energy Transport & Climate, Air & Climate Unit, Via Enrico Fermi 2749, I-21027 Ispra, VA, Italy
[2] Agenzia Nazl Nuove Tecnol Energia & Sviluppo Econ, ENEA, Ispra, VA, Italy
[3] CSIC, Inst Phys & Informat Technol, Madrid, Spain
[4] Phoenix Sistemi & Automaz Sagl, Muralto, TI, Switzerland
来源
关键词
Low-cost gas sensors; Validation; Measurement uncertainty; Multivariate linear regression; Artificial neural network; Air Quality Directive; GAS SENSORS; ARRAY; POLLUTION; PERFORMANCE; OZONE; QUANTIFICATION;
D O I
10.1016/j.snb.2016.07.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work the performances of several field calibration methods for low-cost sensors, including linear/multi linear regression and supervised learning techniques, are compared. A cluster of either metal oxide or electrochemical sensors for nitrogen monoxide and carbon monoxide together with miniaturized infra-red carbon dioxide sensors was operated. Calibration was carried out during the two first weeks of evaluation against reference measurements. The accuracy of each regression method was evaluated on a five months field experiment at a semi-rural site using different indicators and techniques: orthogonal regression, target diagram, measurement uncertainty and drifts over time of sensor predictions. In addition to the analyses for ozone and nitrogen oxide already published in Part A [1], this work assessed if carbon monoxide sensors can reach the Data Quality Objective (DQOs) of 25% of uncertainty set in the European Air Quality Directive for indicative methods. As for ozone and nitrogen oxide, it was found for NO, CO and CO2 that the best agreement between sensors and reference measurements was observed for supervised learning techniques compared to linear and multilinear regression. (C) 2016 The Authors. Published by Elsevier B.V.
引用
收藏
页码:706 / 715
页数:10
相关论文
共 50 条
  • [41] Spatial calibration and PM2.5 mapping of low-cost air quality sensors
    Chu, Hone-Jay
    Ali, Muhammad Zeeshan
    He, Yu-Chen
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [42] Spatial calibration and PM2.5 mapping of low-cost air quality sensors
    Hone-Jay Chu
    Muhammad Zeeshan Ali
    Yu-Chen He
    Scientific Reports, 10
  • [43] Indoor air quality evaluation in oncology units at two European hospitals: Low-cost sensors for TVOCs, PM2.5 and CO2 real-time monitoring
    Palmisani, Jolanda
    Di Gilio, Alessia
    Viana, Mar
    de Gennaro, Gianluigi
    Ferro, Andrea
    BUILDING AND ENVIRONMENT, 2021, 205
  • [44] A Low-Cost Calibration Method for Temperature, Relative Humidity, and Carbon Dioxide Sensors Used in Air Quality Monitoring Systems
    Rivero, Rosa Amalia Gonzalez
    Hernandez, Luis Ernesto Morera
    Schalm, Olivier
    Rodriguez, Erik Hernandez
    Sanchez, Daniellys Alejo
    Perez, Mayra Morales C.
    Caraballo, Vladimir Nunez
    Jacobs, Werner
    Laguardia, Alain Martinez
    ATMOSPHERE, 2023, 14 (02)
  • [45] Challenges in Monitoring Atmospheric CO2Concentrations in Seoul Using Low-Cost Sensors
    Park, Chaerin
    Jeong, Sujong
    Park, Hoonyoung
    Woo, Jung-Hun
    Sim, Sojung
    Kim, Jongho
    Son, Junghoon
    Park, Hayoung
    Shin, Yongseung
    Shin, Jin-ho
    Kwon, Seung-Mi
    Lee, Won-young
    ASIA-PACIFIC JOURNAL OF ATMOSPHERIC SCIENCES, 2021, 57 (03) : 547 - 553
  • [46] A low-cost chamber for rodent CO2 euthanasia
    Cunningham, JJ
    Priddy, DC
    LAB ANIMAL, 1999, 28 (02) : 44 - 45
  • [47] Low-cost separation of CO2 from fluegas
    不详
    CHEMICAL ENGINEERING, 2015, 122 (10) : 7 - 7
  • [48] Low cost CO2 sensing: A simple microcontroller approach with calibration and field use
    Brown, S. L.
    Goulsbra, C. S.
    Evans, M. G.
    Heath, T.
    Shuttleworth, E.
    HARDWAREX, 2020, 8 (08):
  • [49] CO2 fertilization system integrated with a low-cost direct air capture technology
    Wang, Tao
    Huang, Jie
    He, Xin
    Wu, Jiayang
    Fang, Mengxiang
    Cheng, Jun
    12TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-12, 2014, 63 : 6842 - 6851
  • [50] Low-Cost Outdoor Air Quality Monitoring and Sensor Calibration: A Survey and Critical Analysis
    Concas, Francesco
    Mineraud, Julien
    Lagerspetz, Eemil
    Varjonen, Samu
    Liu, Xiaoli
    Puolamaki, Kai
    Nurmi, Petteri
    Tarkoma, Sasu
    ACM TRANSACTIONS ON SENSOR NETWORKS, 2021, 17 (02)