Measurement centration and zone diameter in anterior, posterior and total corneal astigmatism in keratoconus

被引:6
|
作者
Fredriksson, Anneli [1 ]
Behndig, Anders [1 ]
机构
[1] Umea Univ, Dept Clin Sci Ophthalmol, SE-90185 Umea, Sweden
关键词
anterior cornea; astigmatism; keratoconus; posterior cornea; Scheimpflug imaging; INTRAOCULAR-LENS IMPLANTATION; CATARACT-SURGERY; FORME-FRUSTE; EYES; OUTCOMES;
D O I
10.1111/aos.13517
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo investigate the central and paracentral astigmatism and the significance of centration and measurement zone diameter compared to a 3-mm pupil-centred measurement zone in keratoconus and in healthy eyes. MethodsTwenty-eight right eyes from 28 KC patients with an inferotemporal cone were selected according to specified criteria based on Oculus Pentacam HR (R) measurements and were matched with healthy control eyes. The flat (K1) and steep (K2) keratometry readings were registered from the Total Corneal Refractive Power' (TCRP) display as well as the anterior and posterior corneal astigmatism displays (ACA and PCA, respectively). Astigmatic power vectors KP0 and KP45 were calculated and analysed for a 6-mm and two 3-mm zones centred on the corneal apex and the pupil, and for 8 paracentral 3-mm zones. ResultsThe astigmatism was generally higher in KC. Many astigmatic values in KC differed between the 3-mm pupil-centred and the 3- and 6-mm apex-centred zones in KC. In the controls, no corresponding differences between measurement zones were seen, apart from PCA, which differed. The magnitude and direction of KP0 and KP45 varied greatly between the paracentral measurements in KC. ConclusionCentration and measurement zone diameter have great impacts on the astigmatic values in KC. A small pupil-centred measurement zone should be considered when evaluating the astigmatism in KC.
引用
收藏
页码:826 / 833
页数:8
相关论文
共 50 条
  • [41] Fourier analysis of anterior and posterior corneal surface astigmatism.
    Proano, CE
    Proano, JC
    Azar, DT
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S680 - S680
  • [42] Accuracy of Corneal Astigmatism Estimation by Neglecting the Posterior Corneal Surface Measurement
    Ho, Jau-Der
    Tsai, Ching-Yao
    Liou, Shiow-Wen
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (05) : 788 - 795
  • [43] A New Approach for the Calculation of Total Corneal Astigmatism Considering the Magnitude and Orientation of Posterior Corneal Astigmatism and Thickness
    Pinero, David P.
    Caballero, Maria T.
    Nicolas-Albujer, Juan M.
    de Fez, Dolores
    Camps, Vicent J.
    [J]. CORNEA, 2018, 37 (06) : 720 - 726
  • [44] Evaluation of Anterior and Posterior Corneal Higher Order Aberrations for the Detection of Keratoconus and Suspect Keratoconus
    Salman, Abdelrahman
    Kailani, Obeda
    Marshall, John
    Ghabra, Marwan
    Balamoun, Ashraf Armia
    Darwish, Taym R.
    Badla, Abdul Aziz
    Alhaji, Hala
    [J]. TOMOGRAPHY, 2022, 8 (06) : 2864 - 2873
  • [45] Author Response: Total Corneal Astigmatism Measurement Precision
    Savini, Giacomo
    Naeser, Kristian
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (10) : 5913 - 5913
  • [46] Toric Intraocular Lens Calculation Considering Anterior Surgically Induced Astigmatism and Posterior Corneal Astigmatism
    Fernandez, Joaquin
    Rodriguez-Vallejo, Manuel
    Rocha-de-Lossada, Carlos
    Hueso, Elisa
    Pinero, David
    [J]. CURRENT EYE RESEARCH, 2022, 47 (01) : 25 - 31
  • [47] Astigmatism Orientation After Deep Anterior Lamellar Keratoplasty for Keratoconus and Its Correlation With Preoperative Peripheral Corneal Astigmatism
    Elkadim, Mohamed
    Myerscough, James
    Bovone, Cristina
    Busin, Massimo
    [J]. CORNEA, 2020, 39 (02) : 192 - 195
  • [48] A comparison of anterior and posterior central corneal powers in eyes with and without keratoconus
    Chetty, Elizabeth
    Rubin, Alan
    [J]. AFRICAN VISION AND EYE HEALTH JOURNAL, 2021, 79 (01):
  • [49] Evaluation of posterior and total corneal astigmatism with colour-LED topography
    Mendes, Joao
    Ribeiro, Filomena J.
    Ferreira, Tiago B.
    [J]. EYE, 2021, 35 (09) : 2585 - 2593
  • [50] Evaluation of posterior and total corneal astigmatism with colour-LED topography
    João Mendes
    Filomena J. Ribeiro
    Tiago B. Ferreira
    [J]. Eye, 2021, 35 : 2585 - 2593