Evaluation of Anterior and Posterior Corneal Higher Order Aberrations for the Detection of Keratoconus and Suspect Keratoconus

被引:5
|
作者
Salman, Abdelrahman [1 ]
Kailani, Obeda [2 ]
Marshall, John [3 ]
Ghabra, Marwan [4 ]
Balamoun, Ashraf Armia [5 ]
Darwish, Taym R. [1 ]
Badla, Abdul Aziz [6 ]
Alhaji, Hala [1 ]
机构
[1] Tishreen Univ, Dept Ophthalmol, POB 25, Latakia, Syria
[2] Kings Coll Hosp NHS Fdn Trust, London SE5 9RS, England
[3] UCL, Assoc Moorfield Eye Hosp, Inst Ophthalmol, London WC1E 6BT, England
[4] Whipps Cross Univ Hosp, Leytonstone, London E11 1NR, England
[5] Watany Res & Dev Ctr, Cairo 11775, Egypt
[6] Suliman Al Habib Hosp, Dept Ophthalmol, Dubai 41516, U Arab Emirates
关键词
higher-order aberrations; sensitivity; keratoconus suspect; Sirius topography; Scheimpflug; WAVE-FRONT ABERRATIONS; SUBCLINICAL KERATOCONUS; TOPOGRAPHY;
D O I
10.3390/tomography8060240
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: To investigate the application of anterior and posterior corneal higher-order aberrations (HOAs) in detecting keratoconus (KC) and suspect keratoconus (SKC). Method: A retrospective, case-control study evaluating non-ectatic (normal) eyes, SKC eyes, and KC eyes. The Sirius Scheimpfug (CSO, Italy) analyses was used to measure HOAs of the anterior and posterior corneal surfaces. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated. Results: Two-hundred and twenty eyes were included in the analysis (normal n = 108, SKC n = 42, KC n = 70). Receiver operating characteristic (ROC) curve analysis revealed a high predictive ability for anterior corneal HOAs parameters: the root mean square (RMS) total corneal HOAs, RMS trefoil, and RMS coma to detect keratoconus (AUC > 0.9 for all). RMS Coma (3, +/- 1) derived from the anterior corneal surface was the parameter with the highest ability to discriminate between suspect keratoconus and normal eyes (AUC = 0.922; cut-off > 0.2). All posterior corneal HOAs parameters were unsatisfactory in discriminating between SKC and normal eyes (AUC < 0.8 for all). However, their ability to detect KC was excellent with AUC of >0.9 for all except RMS spherical aberrations (AUC = 0.846). Conclusions: Anterior and posterior corneal higher-order aberrations can differentiate between keratoconus and normal eyes, with a high level of certainty. In suspect keratoconus disease, however, only anterior corneal HOAs, and in particular coma-like aberrations, are of value. Corneal aberrometry may be of value in screening for keratoconus in populations with a high prevalence of the disease.
引用
收藏
页码:2864 / 2873
页数:10
相关论文
共 50 条
  • [1] Anterior and posterior corneal higher-order aberrations in early diagnosis and grading of keratoconus
    Yekta, Abbasali
    Hashemi, Hassan
    Ostadimoghaddam, Hadi
    Hadizadeh, Mohsen
    Rafati, Shokoofeh
    Doostdar, Asgar
    Nabovati, Payam
    Sadoughi, Mohammad Mehdi
    Khabazkhoob, Mehdi
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2023, 106 (03) : 263 - 270
  • [2] Higher-Order Aberrations Due to the Posterior Corneal Surface in Patients with Keratoconus
    Nakagawa, Tomoya
    Maeda, Naoyuki
    Kosaki, Ryo
    Hori, Yuichi
    Inoue, Tomoyuki
    Saika, Makoto
    Mihashi, Toshifumi
    Fujikado, Takashi
    Tano, Yasuo
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (06) : 2660 - 2665
  • [3] Corneal higher order aberrations:: A method to grade keratoconus
    Alio, Jorge L.
    Shabayek, Mohamed H.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (06) : 539 - 545
  • [4] Evaluation of corneal topography and higher order aberrations of the fellow eye in unilateral keratoconus
    El Morsy, Mahmoud Mohamed Attia
    Mohamed, Ezz El Dein Galal
    Ghanem, Assad Ahmed Ibrahiem
    Omar, Ismail Ahmed Naguib
    Elhiny, Rasha Safwat
    [J]. JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2023, 116 (03) : 193 - 198
  • [5] Evaluation of corneal topography, pachymetry and higher order aberrations for detecting subclinical keratoconus
    Kandel, Sandeep
    Chaudhary, Meenu
    Mishra, Sanjeeb K.
    Joshi, Niraj D.
    Subedi, Manish
    Puri, Prajjol R.
    Gyawali, Parash
    Bist, Jeewanand
    Kandel, Himal
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2022, 42 (03) : 594 - 608
  • [6] Higher order aberrations in keratoconus
    Erdinest, Nir
    London, Naomi
    Landau, David
    Barbara, Ramez
    Barbara, Adel
    Naroo, Shehzad A.
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [7] Evaluation of higher order ocular aberrations in patients with keratoconus
    Lim, Li
    Wei, Rui Hua
    Chan, Wing Kwong
    Tan, Donald T. H.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (08) : 825 - 828
  • [8] Detection of Subclinical Keratoconus by Using Corneal Anterior and Posterior Surface Aberrations and Thickness Spatial Profiles
    Buehren, Jens
    Kook, Daniel
    Yoon, Geunyoung
    Kohnen, Thomas
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (07) : 3424 - 3432
  • [9] Higher order wavefront aberrations in early keratoconus and keratoconus suspects
    Jafri, B
    Li, X
    Yang, H
    Rabinowitz, YS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [10] Topography and Higher Order Corneal Aberrations of the Fellow Eye in Unilateral Keratoconus
    Koc, Mustafa
    Tekin, Kemal
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2018, 48 (05): : 274 - 275