RETRIEVAL OF A STRIPPED ABUTMENT SCREW: A CLINICAL REPORT

被引:25
|
作者
Maalhagh-Fard, Ahmad [1 ]
Jacobs, Leyvee Cabanilla [1 ]
机构
[1] Univ Detroit Mercy, Sch Dent, Dept Periodontol & Dent Hyg, Detroit, MI 48221 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2010年 / 104卷 / 04期
关键词
OSSEOINTEGRATED IMPLANTS; COMPLICATION; SYSTEM;
D O I
10.1016/S0022-3913(10)00133-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Mechanical complications, such as loosening or damaging of the prosthetic components of an osseointegrated implant, may occur. Stripping of the implant abutment screw head can be a serious problem which can render an implant unusable. This report describes a clinical situation involving a patient who presented with a fractured screw-retained interim crown. Upon further examination, it was determined that the abutment screw head was stripped. There was limited access and visibility in this situation since the implant was a bone-level implant. The procedure used for the removal of the stripped abutment screw head is described in detail in this clinical report. (J Prosthet Dent 2010; 104:212-215)
引用
收藏
页码:212 / 215
页数:4
相关论文
共 50 条
  • [41] From the bathroom to the bone-anchored hearing aid: an idea on how to remove a stripped abutment screw from a bone-anchored hearing aid
    Ferguson, L.
    MacAndie, C.
    CLINICAL OTOLARYNGOLOGY, 2016, 41 (05) : 620 - 621
  • [42] A Technique for Removal of a Fractured Implant Abutment Screw
    Kurt, Murat
    Guler, Ahmet Umut
    Duran, Ibrahim
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (06) : 723 - 726
  • [43] Preload and friction in an implant–abutment–screw complex including a carbon-coated titanium alloy abutment screw: an in vitro study
    K. Sagheb
    C.-I. Görgen
    S. Döll
    I. Schmidtmann
    S. Wentaschek
    International Journal of Implant Dentistry, 9
  • [44] ABUTMENT SELECTION FOR ANTERIOR SINGLE TOOTH REPLACEMENT - A CLINICAL REPORT
    JAGGERS, A
    SIMONS, AM
    BADR, SE
    JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (02): : 133 - 135
  • [45] Customized Locator abutment fabrication on inclined implants: A clinical report
    Kim, Hee-Chul
    Paek, Janghyun
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (04): : 522 - 525
  • [46] THE USE OF A CODED HEALING ABUTMENT AS AN IMPRESSION COPING TO DESIGN AND MILL AN INDIVIDUALIZED ANATOMIC ABUTMENT: A CLINICAL REPORT
    Telleman, Gerdien
    Raghoebar, Gerry M.
    Vissink, Arjan
    Meijer, Henny J. A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (05): : 282 - 285
  • [47] The DIA anatomic abutment system and telescopic prostheses: A clinical report
    Preiskel, HW
    Tsolka, P
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1997, 12 (05) : 628 - 633
  • [48] Does Abutment Collar Length Affect Abutment Screw Loosening After Cyclic Loading?
    Siadat, Hakimeh
    Pirmoazen, Salma
    Beyabanaki, Elaheh
    Alikhasi, Marzieh
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 : 346 - 351
  • [49] The impact of abutment type on abutment screw removal torque value after experimental aging
    Ilic, Gavrilo
    Vulovic, Stefan
    Bukorovic, Jovan
    Dragovic, Miroslav
    Markovic, Aleksa
    Todorovic, Aleksandar
    Lemic, Aleksandra Milic
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [50] Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system
    Kitagawa, T
    Tanimoto, Y
    Odaki, M
    Nemoto, K
    Aida, M
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 75B (02) : 457 - 463