RETRIEVAL OF A STRIPPED ABUTMENT SCREW: A CLINICAL REPORT

被引:25
|
作者
Maalhagh-Fard, Ahmad [1 ]
Jacobs, Leyvee Cabanilla [1 ]
机构
[1] Univ Detroit Mercy, Sch Dent, Dept Periodontol & Dent Hyg, Detroit, MI 48221 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2010年 / 104卷 / 04期
关键词
OSSEOINTEGRATED IMPLANTS; COMPLICATION; SYSTEM;
D O I
10.1016/S0022-3913(10)00133-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Mechanical complications, such as loosening or damaging of the prosthetic components of an osseointegrated implant, may occur. Stripping of the implant abutment screw head can be a serious problem which can render an implant unusable. This report describes a clinical situation involving a patient who presented with a fractured screw-retained interim crown. Upon further examination, it was determined that the abutment screw head was stripped. There was limited access and visibility in this situation since the implant was a bone-level implant. The procedure used for the removal of the stripped abutment screw head is described in detail in this clinical report. (J Prosthet Dent 2010; 104:212-215)
引用
收藏
页码:212 / 215
页数:4
相关论文
共 50 条
  • [21] The influence of abutment screw tightening on screw joint configuration
    Lang, LA
    Wang, RF
    May, KB
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (01): : 74 - 79
  • [22] Fixture abutment screw joint preload of seven abutment systems
    Tan, KBC
    Nicholls, JJ
    Goh, JCH
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1322 - 1322
  • [23] EVULSION OF A PERCUTANEOUS IMPLANT ABUTMENT - A CLINICAL REPORT
    WOLFAARDT, JF
    WILKES, GH
    JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (01): : 1 - 3
  • [24] The Effect of Abutment Screw Length on Screw Loosening in Dental Implants with External Abutment Connections After Thermocycling
    Yeo, In-Sung
    Lee, Joo-Hee
    Kang, Tae-Joo
    Kim, Seong-Kyun
    Heo, Seong-Joo
    Koak, Jai-Young
    Park, Ji-Man
    Lee, Su-Young
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) : 59 - 62
  • [25] Management of a Fractured Implant Abutment Screw
    Flanagan, Dennis
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (06) : 508 - 511
  • [26] The influence of abutment screw tightening an the screw joint configuration.
    Lang, LA
    Wang, RF
    May, KB
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 213 - 213
  • [27] Abutment screw withdrawal after conical abutment settlement: A pilot study
    Yao, Kuang-Ta
    Chang, Tsai-Yu
    Fang, Hsu-Wei
    Huang, Chang-Hung
    Wang, Ding-Han
    Hsu, Ming-Lun
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (02) : 144 - 152
  • [28] Using a Porcelain Furnace to Debond Cement-Retained Implant Crown from the Abutment after Screw Fracture: A Clinical Report
    Saponaro, Paola C.
    Heshmati, Reza H.
    Lee, Damian J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (03): : 239 - 242
  • [29] Removal of locking implants with stripped screw heads
    Kang, Y. C.
    Sechachalam, S.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2017, 42 (01) : 96 - 97
  • [30] Fracture of a fixed partial denture abutment: A clinical report
    Verrett, RG
    Kaiser, DA
    JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (01): : 21 - 23