An automated ECG-artifact removal method for trunk muscle surface EMG recordings

被引:57
|
作者
Mak, Joseph N. F. [1 ]
Hu, Yong [1 ]
Luk, Keith D. K. [1 ]
机构
[1] Univ Hong Kong, Dept Orthopaed & Traumatol, Hong Kong, Hong Kong, Peoples R China
关键词
Surface EMG; ECG artifact; ICA; Automated; INDEPENDENT COMPONENT ANALYSIS; EVENT-SYNCHRONOUS CANCELLATION; DYNAMIC CONTRACTIONS; MYOELECTRIC SIGNALS; INTERFERENCE; EEG; CONTAMINATION; IDENTIFICATION; ELIMINATION; ALGORITHMS;
D O I
10.1016/j.medengphy.2010.05.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aimed at developing a method for automated electrocardiography (ECG) artifact detection and removal from trunk electromyography signals. Independent Component Analysis (ICA) method was applied to the simulated data set of ECG-corrupted surface electromyography (SEMG) signals. Independent Components (ICs) correspond to ECG artifact were then identified by an automated detection algorithm and subsequently removed. The detection performance of the algorithm was compared to that by visual inspection, while the artifact elimination performance was compared with Butterworth high pass filter at 30 Hz cutoff (BW HPF 30). The automated ECG-artifact detection algorithm successfully recognized the ECG source components in all data sets with a sensitivity of 100% and specificity of 99%. Better performance indicated by a significantly higher correlation coefficient (p < 0.001) with the original EMG recordings was found in the SEMG data cleaned by the ICA-based method, than that by BW HPF 30. The automated ECG-artifact removal method for trunk SEMG recordings proposed in this study was demonstrated to produce a very good detection rate and preserved essential EMG components while keeping its distortion to minimum. The automatic nature of our method has solved the problem of visual inspection by standard ICA methods and brings great clinical benefits. (c) 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:840 / 848
页数:9
相关论文
共 50 条
  • [31] Estimation of average muscle fiber conduction velocity from two-dimensional surface EMG recordings
    Farina, D
    Merletti, R
    JOURNAL OF NEUROSCIENCE METHODS, 2004, 134 (02) : 199 - 208
  • [32] Estimation of muscle fiber conduction velocity from two-dimensional surface EMG recordings in dynamic tasks
    Farina, Dario
    Falla, Deborah
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2008, 3 (02) : 138 - 144
  • [33] Muscle Force Estimation Method with Surface EMG for a Lower Extremities Rehabilitation Device
    Bai, Fengjun
    Chew, Chee-Meng
    Li, Jinfu
    Shen, Bingquan
    Lubecki, Tomasz Marek
    2013 IEEE 13TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2013,
  • [34] Real-Time Artifact Removal System for Surface EMG Processing During Ten-Fold Frequency Electrical Stimulation
    Wang, Hai-Peng
    Bi, Zheng-Yang
    Fan, Wen-Jie
    Zhou, Yi-Xin
    Zhou, Yu-Xuan
    Li, Fei
    Wang, Keping
    Lu, Xiao-Ying
    Wang, Zhi-Gong
    IEEE ACCESS, 2021, 9 : 68320 - 68331
  • [35] Real-Time Artifact Removal System for Surface EMG Processing during Ten-Fold Frequency Electrical Stimulation
    Wang, Hai-Peng
    Bi, Zheng-Yang
    Fan, Wen-Jie
    Zhou, Yi-Xin
    Zhou, Yu-Xuan
    Li, Fei
    Wang, Keping
    Lu, Xiao-Ying
    Wang, Zhi-Gong
    IEEE Access, 2021, 9 : 68320 - 68331
  • [36] Application of hybrid GLCT-PICA de-noising method in automated EEG artifact removal
    Jindal, K.
    Upadhyay, R.
    Singh, H. S.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 60
  • [37] Improving MEG source localizations: An automated method for complete artifact removal based on independent component analysis
    Mantini, D.
    Franciotti, R.
    Romani, G. L.
    Pizzella, V.
    NEUROIMAGE, 2008, 40 (01) : 160 - 173
  • [38] Surface EMG Recordings in Freely Moving Rats: A Promising Method for Motor Evaluation and for Minimizing Animal Use in Research
    Rivolta, Luciano
    Cano, Leonardo A.
    Tagashira, Celia
    Maranon, Rodrigo
    Farfan, Fernando
    Albarracin, Ana Lia
    ADVANCES IN BIOENGINEERING AND CLINICAL ENGINEERING, VOL 2, SABI 2023, 2024, 114 : 102 - 110
  • [39] Surface EMG led by source derivation method is suitable for recording local muscle activity
    Okamura, Noritaka
    JOURNAL OF PHYSIOLOGICAL SCIENCES, 2010, 60 : S193 - S193
  • [40] Automated diagnosis of muscle diseases from EMG signals using empirical mode decomposition based method
    Dubey, Rahul
    Kumar, Mohit
    Upadhyay, Abhay
    Pachori, Ram Bilas
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 71