Improving MEG source localizations: An automated method for complete artifact removal based on independent component analysis

被引:73
|
作者
Mantini, D. [1 ]
Franciotti, R. [1 ]
Romani, G. L. [1 ]
Pizzella, V. [1 ]
机构
[1] Univ Studi Chieti G DAnnunzio, Fdn Univ G DAnnunzio, Inst Tecnol Avanzate Biomed, I-66013 Chieti, Italy
关键词
approximate entropy; artifact removal; blind source separation; independent component analysis; magnetoencephalography; source localization;
D O I
10.1016/j.neuroimage.2007.11.022
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The major limitation for the acquisition of high-quality magnetoencephalography (MEG) recordings is the presence of disturbances of physiological and technical origins: eye movements, cardiac signals, muscular contractions, and environmental noise are serious problems for MEG signal analysis. In the last years, multi-channel MEG systems have undergone rapid technological developments in terms of noise reduction, and many processing methods have been proposed for artifact rejection. Independent component analysis (ICA) has already shown to be an effective and generally applicable technique for concurrently removing artifacts and noise from the MEG recordings. However, no standardized automated system based on ICA has become available so far, because of the intrinsic difficulty in the reliable categorization of the source signals obtained with this technique. In this work, approximate entropy (ApEn), a measure of data regularity is successfully used for the classification of the signals produced by ICA, allowing for an automated artifact rejection. The proposed method has been tested using MEG data sets collected during somatosensory, auditory and visual stimulation. It was demonstrated to be effective in attenuating both biological artifacts and environmental noise, in order to reconstruct clear signals that can be used for improving brain source localizations. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:160 / 173
页数:14
相关论文
共 50 条
  • [1] EEG Artifact Removal Based on Independent Component Analysis and Outlier Detection
    Wang, Xinxin
    Wang, Xiuwei
    Zhou, Biao
    2022 14TH INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS AND SIGNAL PROCESSING, WCSP, 2022, : 209 - 214
  • [2] Spatially constrained independent component analysis for artifact correction in EEG and MEG
    Ille, N
    Beucker, R
    Scherg, M
    NEUROIMAGE, 2001, 13 (06) : S159 - S159
  • [3] Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis
    Mantini, D.
    Perrucci, M. G.
    Cugini, S.
    Ferretti, A.
    Romani, G. L.
    Del Gratta, C.
    NEUROIMAGE, 2007, 34 (02) : 598 - 607
  • [4] An automated method for identifying artifact in independent component analysis of resting-state fMRI
    Bhaganagarapu, Kaushik
    Jackson, Graeme D.
    Abbott, David F.
    FRONTIERS IN HUMAN NEUROSCIENCE, 2013, 7
  • [5] Automated EEG Artifact Detection Using Independent Component Analysis
    Echtioui, Amira
    Zouch, Wassim
    Ghorbel, Mohamed
    Ben Slima, Mohamed
    Ben Hamida, Ahmed
    Mhiri, Chokri
    2020 5TH INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES FOR SIGNAL AND IMAGE PROCESSING (ATSIP'2020), 2020,
  • [6] Artifact removal in magnetoencephalogram background activity with independent component analysis
    Escudero, Javier
    Hornero, Roberto
    Abasolo, Daniel
    Fernandez, Alberto
    Lopez-Coronado, Miguel
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (11) : 1965 - 1973
  • [7] Magnetoencephalographic artifact identification and automatic removal based on independent component analysis and categorization approaches
    Rong, Feng
    Contreras-Vidal, Jose L.
    JOURNAL OF NEUROSCIENCE METHODS, 2006, 157 (02) : 337 - 354
  • [8] Automated Removal of EKG Artifact From EEG Data Using Independent Component Analysis and Continuous Wavelet Transformation
    Hamaneh, Mehdi Bagheri
    Chitravas, Numthip
    Kaiboriboon, Kitti
    Lhatoo, Samden D.
    Loparo, Kenneth A.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (06) : 1634 - 1641
  • [9] Enhanced Automatic Wavelet Independent Component Analysis for Electroencephalographic Artifact Removal
    Mammone, Nadia
    Morabito, Francesco C.
    ENTROPY, 2014, 16 (12) : 6553 - 6572
  • [10] The Removal of Blink and Saccade Artifact in EEG recordings by Independent Component Analysis
    Dong, Jie
    Wang, Tao
    Zhang, Ai-tao
    Dai, Hong-ya
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1071 - 1075