Interruption of Low-Voltage DC Arc in Air Under Axial Magnetic Field

被引:7
|
作者
Islam, Asif [1 ]
Birtwhistle, David [2 ]
Saha, Tapan K. [2 ]
Islam, Mohammad Shariful [1 ]
机构
[1] NOJA Power Ltd, R&D & Testing Dept, Brisbane, Qld, Australia
[2] Univ Queensland, Sch ITEE, Power & Energy Syst Res Grp, Brisbane, Qld, Australia
关键词
Magnetic fields; Electrodes; Magnetic field measurement; Fuses; Magnetic circuits; Current measurement; Switches; Free-burning arc; thermal breakdown; axial magnetic field; current interruption; arc movement speed; VELOCITY;
D O I
10.1109/TPWRD.2019.2932456
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper represents the findings from our research in which a series of experiments were conducted on dc current interruption in air in axial magnetic field provided from rare earth magnets mounted in the test electrodes. The experimental range was as follows: arc voltage 80-100 V, arc length 5-10 mm, arc current 80-800 A, and applied field 35-2400 G. The free-burning arc diameter was measured in these experiments from high-speed photographs. It was found that a strong magnetic field can improve the interruption capacity of air-arc significantly. In the experiments, the successful switching time of both 220 and 330 A free-burning air-arc in 2.4 kG was less than half of the successful switching time of corresponding free-burning arcs in air. For higher current arcs, the outcome was more encouraging. An 800 A free-burning arc sustained for about 48 ms, whereas a 315 G field interrupted it within 8 ms. The information found on arc-root diameter and current density of 80-800 A free-burning arcs in air has filled a gap of data found in the literature. This information, in turn, will help to improve the theories available on free-burning arcs.
引用
收藏
页码:977 / 986
页数:10
相关论文
共 50 条
  • [31] Arc behavior in low-voltage arc chambers
    Mutzke, A.
    Ruether, T.
    Lindmayer, M.
    Kurrat, M.
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2010, 49 (02):
  • [32] AN INVESTIGATION OF CURRENT INTERRUPTION IN LOW-VOLTAGE CIRCUITS
    SLADE, PG
    IEEE TRANSACTIONS ON PARTS MATERIALS AND PACKAGING, 1969, PMP5 (01): : 56 - &
  • [33] Current Interruption in Low-Voltage Circuit Breakers
    Balestrero, Andrea
    Ghezzi, Luca
    Popov, Marjan
    van der Sluis, Lou
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (01) : 206 - 211
  • [34] Numerical investigations on the electric arc behavior upon contact opening in a low-voltage switch under the effect of external magnetic field
    Almurr, Jessica
    Bussiere, William
    Hertzog, Jerome
    Rochette, David
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 209
  • [35] The influence of electrode erosion on the air arc in a low-voltage circuit breaker
    Rong, Mingzhe
    Ma, Qiang
    Wu, Yi
    Xu, Tiejun
    Murphy, Anthony B.
    JOURNAL OF APPLIED PHYSICS, 2009, 106 (02)
  • [36] Wavelet Packet Analysis Applied in Detection of Low-voltage DC Arc Fault
    Guo Yunmei
    Wang Li
    Wu Zhuoqi
    Jiang Binfeng
    ICIEA: 2009 4TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-6, 2009, : 4004 - 4007
  • [37] LOW-VOLTAGE DC-TO-DC-CONVERTER
    AINSCOW, F
    WIRELESS WORLD, 1978, 84 (1511): : 74 - 74
  • [38] Influence of axial magnetic field on DC arc plasma in vacuum breaker
    School of Electrical Engineering, Shenyang University of Technology, Shenyang, China
    不详
    Zhenkong Kexue yu Jishu Xuebao, 11 (1374-1379):
  • [39] LOW-VOLTAGE ARC IN CESIUM VAPORS
    GUSKOV, YK
    LEBEDEV, MA
    STAKHANO.IP
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1965, 9 (08): : 1122 - &
  • [40] LOW-VOLTAGE ARC IN CESIUM VAPORS
    DUNAEV, YA
    YAVOR, IP
    BUSYGIN, EP
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1966, 11 (03): : 395 - &