Investigation of the dosimetric effect of respiratory motion using four-dimensional weighted radiotherapy

被引:2
|
作者
Vandermeer, Aaron D. [1 ]
Alasti, Hamideh
Cho, Young-Bin
Norrlinger, Bern
机构
[1] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 15期
关键词
D O I
10.1088/0031-9155/52/15/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a four-dimensional weighted radiotherapy ( 4DW-RT) technique. This method involves designing the motion of the linear accelerator beam to coincide with the tumour motion determined from 4D-CT imaging while including a weighting factor to account for irregular motion and limitations of the delivery system. Experiments were conducted with a moving phantom to assess limitations of the delivery system when applying this method. Although the multi-leaf collimator motion remains within the tolerance of the linear accelerator, the extent of motion was less than 1 mm larger than the designed one, and there was a net system latency of approximately 0.2 s. The dose distributions were measured and simulated using different weighting factors and motion scenarios. The breathing characteristics ( period, extent of motion, drift and standard deviations) of 32 patients were evaluated using the Varian RPM system. Breathing variability was assessed by plotting the average breathing motion as a function of the breathing phase. Simulations were carried out to determine the optimal weighting factor based on typical patient breathing characteristics. These results establish that the 4DW-RT method demonstrates potential for dose escalation without increasing exposure to healthy tissue.
引用
收藏
页码:4427 / 4448
页数:22
相关论文
共 50 条
  • [41] Dosimetric comparison of four-dimensional computed tomography based internal target volume against variations in respiratory motion during treatment between volumetric modulated arc therapy and three-dimensional conformal radiotherapy in lung stereotactic body radiotherapy
    Daimu Fujimoto
    Jun Takatsu
    Naoya Hara
    Masaki Oshima
    Jun Tomihara
    Eisuke Segawa
    Tatsuya Inoue
    Naoto Shikama
    Radiological Physics and Technology, 2024, 17 : 143 - 152
  • [42] Dosimetric comparison of four-dimensional computed tomography based internal target volume against variations in respiratory motion during treatment between volumetric modulated arc therapy and three-dimensional conformal radiotherapy in lung stereotactic body radiotherapy
    Fujimoto, Daimu
    Takatsu, Jun
    Hara, Naoya
    Oshima, Masaki
    Tomihara, Jun
    Segawa, Eisuke
    Inoue, Tatsuya
    Shikama, Naoto
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (01) : 143 - 152
  • [43] The use of respiratory-correlated four-dimensional CT where kidney motion has the potential to impact upon the radiotherapy planning process
    Gawthrop, Janet B.
    Gill, Suki
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (06) : 689 - 695
  • [44] The effect of respiratory motion variability and tumor size on the accuracy of average intensity projection from four-dimensional computed tomography: An investigation based on dynamic MRI
    Cai, Jing
    Read, Paul W.
    Sheng, Ke
    MEDICAL PHYSICS, 2008, 35 (11) : 4974 - 4981
  • [45] Effect of audio instruction on tracking errors using a four-dimensional image-guided radiotherapy system
    Nakamura, Mitsuhiro
    Sawada, Akira
    Mukumoto, Nobutaka
    Takahashi, Kunio
    Mizowaki, Takashi
    Kokubo, Masaki
    Hiraoka, Masahiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (05): : 255 - 264
  • [46] Radiobiological Evaluation On the Four-Dimensional Stereotactic Radiotherapy Plan
    Su, F.
    Shi, C.
    Mavroidis, P.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2008, 35 (06) : 2824 - +
  • [47] ASSESSMENT OF NON-SMALL-CELL LUNG CANCER TUMOR MOTION, DOSIMETRIC COVERAGE AND REGRESSION USING FOUR-DIMENSIONAL COMPUTED TOMOGRAPHY
    Houle, A.
    Martel, C.
    Blais, D.
    Despres, P.
    Boudam, K.
    Campeau, M. P.
    Filion, E.
    Vu, T. T. Thuc
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S544 - S545
  • [48] Four-dimensional treatment planning for stereotactic body radiotherapy
    Guckenberger, Matthias
    Wilbert, Juergen
    Krieger, Thomas
    Richter, Anne
    Baier, Kurt
    Meyer, Juergen
    Flentje, Michael
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01): : 276 - 285
  • [49] Work in progress: Four-dimensional ultrasound for investigation of arterial wall and carotid plaque motion
    Hennerici, M
    Meairs, S
    INTIMA-MEDIA THICKNESS AN ATHEROSCLEROSIS: PREDICTING THE RISK?, 1997, : 75 - 80
  • [50] Four-dimensional measurement of intrafractional respiratory motion of pancreatic tumors using a 256 multi-slice CT scanner
    Mori, Shinichiro
    Hara, Ryusuke
    Yanagi, Takeshi
    Sharp, Gregory C.
    Kumagai, Motoki
    Asakura, Hiroshi
    Kishimoto, Riwa
    Yamada, Shigeru
    Kandatsu, Susumu
    Kamada, Tadashi
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 (02) : 231 - 237