Estimation of Blood Pressure in the Radial Artery Using Strain-Based Pulse Wave and Photoplethysmography Sensors

被引:33
|
作者
Wang, Yu-Jen [1 ]
Chen, Chia-Hsien [1 ]
Sue, Chung-Yang [2 ]
Lu, Wen-Hsien [3 ,4 ]
Chiou, Yee-Hsuan [3 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Mech & Electromech Engn, Kaohsiung 80424, Taiwan
[2] Ind Technol Res Inst, Smart Microsyst Technol Ctr, Tainan 70955, Taiwan
[3] Kaohsiung Vet Gen Hosp, Dept Pediat, Kaohsiung 81362, Taiwan
[4] Natl Yang Ming Univ, Fac Med, Taipei 11221, Taiwan
来源
MICROMACHINES | 2018年 / 9卷 / 11期
关键词
continuous blood pressure measurement; radial artery; strain gauge; photoplethysmography; pulse transit time;
D O I
10.3390/mi9110556
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Blood pressure (BP) is a crucial indicator of cardiac health and vascular status. This study explores the relationship between radial artery BP and wrist skin strain. A BP estimation method based on the physical model of wrist skin tissues and pulse wave velocity (PWV) is proposed. A photoplethysmography (PPG) sensor and strain gauge are used in this method. The developed strain-based pulse wave sensor consists of a pressing force sensor, which ensures consistent pressing force, and a strain gauge, which measures the cardiac pulsation on the wrist skin. These features enable long-term BP monitoring without incurring the limb compression caused by a cuff. Thus, this method is useful for individuals requiring continuous BP monitoring. In this study, the BP of each participant was measured in three modes (before, during, and after exercise), and the data were compared using a clinically validated sphygmomanometer. The percentage errors of diastolic and systolic BP readings were, respectively, 4.74% and 4.49% before exercise, 6.38% and 6.10% during exercise, and 5.98% and 4.81% after a rest. The errors were compared with a clinically validated sphygmomanometer.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Pulse Transition Characterization from Electrocardiography and Photoplethysmography for Non-Invasive Blood Pressure Estimation
    Mohammed, Hazem
    Wu, Hao
    Wang, Guoxing
    2022 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 22), 2022, : 2841 - 2845
  • [42] Methods for reliable estimation of pulse transit time and blood pressure variations using smartphone sensors
    Dias, Alair, Jr.
    Murali, Srinivasan
    Rincon, Francisco
    Atienza, David
    MICROPROCESSORS AND MICROSYSTEMS, 2016, 46 : 84 - 95
  • [43] Measurement of a Blood Velocity by using Photoplethysmograph and Radial Artery Pulse Wave Equipped with Magnetic Hall Device
    Jang, Deok-Hyeong
    Kim, Dam-Bee
    Choi, Suel-Gi
    Lee, Sang-Suk
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2012, 22 (04): : 130 - 135
  • [44] Contactless video-based photoplethysmography technique comparison investigating pulse transit time estimation of arterial blood pressure
    Shirbani, Fatemeh
    Moriarty, Aidan
    Hui, Nicholas
    Cox, James
    Tan, Isabella
    Avolio, Alberto P.
    Butlin, Mark
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 5650 - 5653
  • [45] Model-Based Estimation of Radial Artery Blood Pressure from Recordings of the Nexfin Monitor
    Imaduddin, Syed M.
    Heldt, Thomas
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 1692 - 1695
  • [46] Photoplethysmography Based Blood Pressure Monitoring Using the Senbiosys Ring
    Haddad, Serj
    Boukhayma, Assim
    Di Pietrantonio, Gilles
    Barison, Anthony
    de Preux, Gilles
    Caizzone, Antonino
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 1609 - 1612
  • [47] Blood Pressure Evaluation Based on Photoplethysmography Using Deep Learning
    Sun Xiaoxiao
    Zhou Liang
    Liu Zhaohui
    Yu Jiangjun
    Qiao Wenlong
    AOPC 2020: OPTICAL SPECTROSCOPY AND IMAGING; AND BIOMEDICAL OPTICS, 2020, 11566
  • [48] A Fast Multimodal Ectopic Beat Detection Method Applied for Blood Pressure Estimation Based on Pulse Wave Velocity Measurements in Wearable Sensors
    Pflugradt, Maik
    Geissdoerfer, Kai
    Goernig, Matthias
    Orglmeister, Reinhold
    SENSORS, 2017, 17 (01)
  • [49] Pulse wave registration from radial artery using photoplethysmographic method
    Pilt, Kristjan
    Leier, Mairo
    Silluta, Sandra
    Koeoets, Kristina
    Meigas, Kalju
    Viigimaa, Margus
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 6425 - 6428
  • [50] Noninvasive Cuffless Estimation of Blood Pressure using Photoplethysmography without Electrocardiograph Measurement
    Samria, Rohan
    Jain, Ridhi
    Jha, Ankita
    Saini, Sandeep
    Chowdhury, Shubhajit Roy
    2014 IEEE REGION 10 SYMPOSIUM, 2014, : 254 - 257