Estimation of Blood Pressure in the Radial Artery Using Strain-Based Pulse Wave and Photoplethysmography Sensors

被引:33
|
作者
Wang, Yu-Jen [1 ]
Chen, Chia-Hsien [1 ]
Sue, Chung-Yang [2 ]
Lu, Wen-Hsien [3 ,4 ]
Chiou, Yee-Hsuan [3 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Mech & Electromech Engn, Kaohsiung 80424, Taiwan
[2] Ind Technol Res Inst, Smart Microsyst Technol Ctr, Tainan 70955, Taiwan
[3] Kaohsiung Vet Gen Hosp, Dept Pediat, Kaohsiung 81362, Taiwan
[4] Natl Yang Ming Univ, Fac Med, Taipei 11221, Taiwan
来源
MICROMACHINES | 2018年 / 9卷 / 11期
关键词
continuous blood pressure measurement; radial artery; strain gauge; photoplethysmography; pulse transit time;
D O I
10.3390/mi9110556
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Blood pressure (BP) is a crucial indicator of cardiac health and vascular status. This study explores the relationship between radial artery BP and wrist skin strain. A BP estimation method based on the physical model of wrist skin tissues and pulse wave velocity (PWV) is proposed. A photoplethysmography (PPG) sensor and strain gauge are used in this method. The developed strain-based pulse wave sensor consists of a pressing force sensor, which ensures consistent pressing force, and a strain gauge, which measures the cardiac pulsation on the wrist skin. These features enable long-term BP monitoring without incurring the limb compression caused by a cuff. Thus, this method is useful for individuals requiring continuous BP monitoring. In this study, the BP of each participant was measured in three modes (before, during, and after exercise), and the data were compared using a clinically validated sphygmomanometer. The percentage errors of diastolic and systolic BP readings were, respectively, 4.74% and 4.49% before exercise, 6.38% and 6.10% during exercise, and 5.98% and 4.81% after a rest. The errors were compared with a clinically validated sphygmomanometer.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Inverse-model-based cuffless blood pressure estimation using a single photoplethysmography sensor
    Suzuki, Arata
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2015, 229 (07) : 499 - 505
  • [32] A Refined Blood Pressure Estimation Model Based on Single Channel Photoplethysmography
    Zhang, Yiming
    Ren, Xianglin
    Liang, Xiao
    Ye, Xuesong
    Zhou, Congcong
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (12) : 5907 - 5917
  • [33] Noninvasive Continuous Blood Pressure Estimation using Attention-U-Net based on photoplethysmography
    Bai, Jiangtao
    Li, Zhe
    Feng, Jinchao
    Jia, Kebin
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS XIII, 2023, 12770
  • [34] Considerations for SphygmoCor radial artery pulse wave analysis: side selection and peripheral arterial blood pressure calibration
    Martin, Jeffrey S.
    Borges, Alexandra R.
    Christy, John B.
    Beck, Darren T.
    HYPERTENSION RESEARCH, 2015, 38 (10) : 675 - 683
  • [35] Considerations for SphygmoCor radial artery pulse wave analysis: side selection and peripheral arterial blood pressure calibration
    Jeffrey S Martin
    Alexandra R Borges
    John B Christy IV
    Darren T Beck
    Hypertension Research, 2015, 38 : 675 - 683
  • [36] An Independent Component Analysis Based Estimation of Ambulatory Blood Pressure from the Radial Pulse Waveform
    Zhang, Zheng
    Chen, Zhihua
    He, Long
    JOURNAL OF COMPUTATIONAL AND THEORETICAL NANOSCIENCE, 2015, 12 (07) : 1234 - 1241
  • [37] Transient stress-based and strain-based hemolysis estimation in a simplified blood pump
    Pauli, Lutz
    Nam, Jaewook
    Pasquali, Matteo
    Behr, Marek
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2013, 29 (10) : 1148 - 1160
  • [38] Strain-based blood damage estimation for computational design of ventricular assist devices
    Gesenhues, Linda (Linda.gesenhues@rwth-aachen.de), 1600, Wichtig Publishing Srl (39):
  • [39] Strain-based blood damage estimation for computational design of ventricular assist devices
    Gesenhues, Linda
    Pauli, Lutz
    Behr, Marek
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2016, 39 (04): : 166 - 170
  • [40] An Automatic Pulse Wave Velocity Estimation using a Blood Pressure Sensor for Invasive Measurement
    Choi, Junghyeon
    Park, Junho
    Cho, Jongman
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY, 2008, : 539 - 542