Optimization in high dose rate brachytherapy for utero-vaginal applications

被引:12
|
作者
Çetingöz, R [1 ]
Ataman, ÖU [1 ]
Tuncel, N [1 ]
Sen, M [1 ]
Kinay, M [1 ]
机构
[1] Dokuz Eylul Univ, Sch Med, Dept Radiat Oncol, T-35340 Izmir, Turkey
关键词
optimization; intracavitary brachytherapy; tumour volume; organs at risk;
D O I
10.1016/S0167-8140(00)00295-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: High dose rate (HDR) remote afterloading intracavitary brachytherapy is an effective treatment modality which has some advantages over low dose rate (LDR) techniques for gynaecological cancer. Optimization is one of the possibilities of modem brachytherapy techniques, especially the stepping source technology. The use of the term 'optimization' implies achieving the desired optimum dose distribution by changing some parameters of the treatment. The aim of this study was to theoretically evaluate the optimization possibilities by modifying dwell times and dwell positions of the uterine and vaginal sources. Materials and methods: Working on a virtual utero-vaginal model, the dose distribution variations in the rectum, bladder, mean point B reference points and volume parameters were investigated whilst giving a standard dose to point A in the Manchester system. In this model, the intrauterine tandem consisted of 27 dwell positions for 2.5 mm steps and 14 dwell positions for 5 mm steps. Vaginal colpostats consisted of five dwell positions each for 2.5 mm steps. Using a Nucletron Plate treatment planning system and a Microselectron Ir-192 HDR stepping source unit, the dwell times of the intrauterine (T-u) and vaginal sources (T-v) were modified at the ratios of (T-u/T-v) 1:1; 1:2; 1:3; 1:4; 1:0.50; 1:0.33; and 1:0.25 for the two different dwell positions, 2.5 and 5 mm steps, of the intrauterine tandem. Results: All evaluated parameters decreased with increasing dwell time ratios of uterine tandem to Vaginal colpostats, with the greatest fail in the percentage of rectum reference dose (D-R %), 23 and 28% for 2.5 and 5 mm dwell positions respectively; in addition, the reference isodose volume decreased by 14 and 17% for 2.5 and 5 mm dwell positions, respectively. All evaluated parameters increased with decreasing dwell time ratios of uterine tandem to vaginal colpostats for both dwell positions. The DR% of 1:1-1:4 (T-u/T-v) weightings showed an increase from 40.6 to 58.3 (44%) for 2.5 mm and from 49.2 to 67.5 (37%) for 5 mm dwell positions. The volume was increased by 27 and 37% for 2.5 and 5 mm dwell positions respectively. Conclusions: Modern brachytherapy techniques enable the individualization of treatments by optimization procedures in gynaecological brachytherapy applications. By altering the dwell time and position, some important changes in reference points, volume and treatment time can be achieved, whilst maintaining a standard dose to point A. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [41] ADHERENCE TO VAGINAL DILATION FOLLOWING HIGH DOSE RATE BRACHYTHERAPY FOR ENDOMETRIAL CANCER
    Friedman, Lois C.
    Abdallah, Rita
    Schluchter, Mark
    Panneerselvam, Ashok
    Kunos, Charles A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (03): : 751 - 757
  • [42] High-dose rate vaginal brachytherapy in early stage endometrial cancer
    Perrucci, E.
    Lancellotta, V.
    Bini, V.
    Mariucci, C.
    Di Benedetto, M.
    Trinari, S.
    Verzini, S.
    Aristei, C.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S549 - S550
  • [43] Carbonic anhydrase in the utero-vaginal junction of immature and mature ostriches
    Holm, L
    Ruziwa, SD
    Dantzer, V
    Ridderstråale, Y
    BRITISH POULTRY SCIENCE, 2000, 41 (02) : 244 - 249
  • [44] High Dose Rate Brachytherapy Optimization Based on the Generalized Equivalent Uniform Dose
    Giantsoudi, D.
    Baltas, D.
    Karabis, A.
    Mavroidis, P.
    Shi, C.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [45] HIGH DOSE RATE BRACHYTHERAPY OPTIMIZATION BASED ON THE GENERALIZED EQUIVALENT UNIFORM DOSE
    Giantsoudi, D.
    Baltas, D.
    Karabis, A.
    Mavroidis, P.
    Shi, C.
    Papanikolaou, N.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S40 - S41
  • [46] FILLING RATES OF THE TURKEY UTERO-VAGINAL SPERM STORAGE GLANDS
    MCINTYRE, DR
    CHRISTENSEN, VL
    POULTRY SCIENCE, 1982, 61 (07) : 1389 - 1389
  • [47] UTERO-VAGINAL DIFFERENTIAL PRESSURE DURING FIRST STAGE OF LABOUR
    WESTIN, B
    SODERBERG, G
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1971, 50 (03) : 223 - +
  • [48] Hydronephrosis and utero-vaginal prolapse in postmenopausal women: management and treatment
    Leanza, V.
    Ciotta, L.
    Vecchio, R.
    Zanghi, G.
    Maiorana, A.
    Leanza, G.
    GIORNALE DI CHIRURGIA, 2015, 36 (06): : 251 - 256
  • [49] ASPECTS RADIOLOGIQUES DU PROLAPSUS UTERO-VAGINAL ET VESICAL
    VERESS, E
    VOLET, B
    GYNAECOLOGIA, 1964, 158 (06): : 357 - 374
  • [50] VAGINOPEXY TECHNIQUE FOR THE MANAGEMENT OF RECURRENT UTERO-VAGINAL PROLAPSE IN BOVINES
    MISRA, SS
    ANGELO, SJ
    INDIAN VETERINARY JOURNAL, 1981, 58 (07): : 576 - &