Optimization in high dose rate brachytherapy for utero-vaginal applications

被引:12
|
作者
Çetingöz, R [1 ]
Ataman, ÖU [1 ]
Tuncel, N [1 ]
Sen, M [1 ]
Kinay, M [1 ]
机构
[1] Dokuz Eylul Univ, Sch Med, Dept Radiat Oncol, T-35340 Izmir, Turkey
关键词
optimization; intracavitary brachytherapy; tumour volume; organs at risk;
D O I
10.1016/S0167-8140(00)00295-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: High dose rate (HDR) remote afterloading intracavitary brachytherapy is an effective treatment modality which has some advantages over low dose rate (LDR) techniques for gynaecological cancer. Optimization is one of the possibilities of modem brachytherapy techniques, especially the stepping source technology. The use of the term 'optimization' implies achieving the desired optimum dose distribution by changing some parameters of the treatment. The aim of this study was to theoretically evaluate the optimization possibilities by modifying dwell times and dwell positions of the uterine and vaginal sources. Materials and methods: Working on a virtual utero-vaginal model, the dose distribution variations in the rectum, bladder, mean point B reference points and volume parameters were investigated whilst giving a standard dose to point A in the Manchester system. In this model, the intrauterine tandem consisted of 27 dwell positions for 2.5 mm steps and 14 dwell positions for 5 mm steps. Vaginal colpostats consisted of five dwell positions each for 2.5 mm steps. Using a Nucletron Plate treatment planning system and a Microselectron Ir-192 HDR stepping source unit, the dwell times of the intrauterine (T-u) and vaginal sources (T-v) were modified at the ratios of (T-u/T-v) 1:1; 1:2; 1:3; 1:4; 1:0.50; 1:0.33; and 1:0.25 for the two different dwell positions, 2.5 and 5 mm steps, of the intrauterine tandem. Results: All evaluated parameters decreased with increasing dwell time ratios of uterine tandem to Vaginal colpostats, with the greatest fail in the percentage of rectum reference dose (D-R %), 23 and 28% for 2.5 and 5 mm dwell positions respectively; in addition, the reference isodose volume decreased by 14 and 17% for 2.5 and 5 mm dwell positions, respectively. All evaluated parameters increased with decreasing dwell time ratios of uterine tandem to vaginal colpostats for both dwell positions. The DR% of 1:1-1:4 (T-u/T-v) weightings showed an increase from 40.6 to 58.3 (44%) for 2.5 mm and from 49.2 to 67.5 (37%) for 5 mm dwell positions. The volume was increased by 27 and 37% for 2.5 and 5 mm dwell positions respectively. Conclusions: Modern brachytherapy techniques enable the individualization of treatments by optimization procedures in gynaecological brachytherapy applications. By altering the dwell time and position, some important changes in reference points, volume and treatment time can be achieved, whilst maintaining a standard dose to point A. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [31] UTERO-VAGINAL PROLAPSE IN GIR COWS AND THEIR EXOTIC CROSSES
    SHUKLA, SP
    PAREKH, HKB
    INDIAN VETERINARY JOURNAL, 1987, 64 (12): : 1050 - 1052
  • [32] Radiotherapy alone for invasive vaginal cancer:: outcome with intracavitary high dose rate brachytherapy versus conventional low dose rate brachytherapy
    Kucera, H
    Mock, U
    Knocke, TH
    Kucera, E
    Pötter, R
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2001, 80 (04) : 355 - 360
  • [33] Three-dimension anatomy-based planning optimization for high dose rate vaginal vault brachytherapy
    Bahadur, Yasir A.
    Hassouna, Ashraf H.
    Constantinescu, Camelia T.
    Naga, Adly F.
    Ghasal, Noor M.
    Elsayed, Mohamed E.
    SAUDI MEDICAL JOURNAL, 2012, 33 (06) : 640 - 647
  • [34] Increased incidence of vaginal adenosis in children with selected utero-vaginal anomalies.
    Prasad, V
    Perez-Atayde, AR
    Vargas, SO
    Nosé, V
    Laufer, M
    Kozakewich, HPW
    MODERN PATHOLOGY, 2004, 17 (02) : 272 - 272
  • [35] Bayesian Optimization in Treatment Planning of High Dose Rate Brachytherapy
    Jafarzadeh, H.
    Mao, X.
    Enger, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E200 - E200
  • [36] Adherence to Vaginal Dilation following High Dose Rate Brachytherapy for Endometrial Cancer
    Friedman, L. C.
    Abdallah, R.
    Schluchter, M.
    Panneerselvam, A.
    Kunos, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S522 - S522
  • [37] Optimal Design of Multichannel Vaginal Cylinder Applicators for High Dose Rate Brachytherapy
    Park, S.
    Demanes, J.
    Kamrava, M.
    MEDICAL PHYSICS, 2012, 39 (06) : 3611 - 3611
  • [38] The use and advantages of a multichannel vaginal cylinder in high-dose-rate brachytherapy
    Demanes, DJ
    Rege, S
    Rodriquez, RR
    Schutz, KL
    Altieri, GA
    Wong, T
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (01): : 211 - 219
  • [39] RADIOGRAPHIC VISUALIZATION OF VAGINAL CYLINDERS IN GYNECOLOGIC HIGH-DOSE RATE BRACHYTHERAPY
    PODGORSAK, MB
    PALIWAL, BR
    THOMADSEN, BR
    STITT, JA
    BUCHLER, DA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03): : 525 - 527
  • [40] Treatment of Vaginal Recurrences in Endometrial Carcinoma by High-dose-rate Brachytherapy
    Sorbe, Bengt
    Soderstrom, Karin
    ANTICANCER RESEARCH, 2013, 33 (01) : 241 - 247