Real-time tumor-tracking radiotherapy for adrenal tumors

被引:61
|
作者
Katoh, Norio [1 ]
Onimaru, Rikiya [1 ]
Sakuhara, Yusuke [1 ]
Abo, Daisuke [1 ]
Shimizu, Shinichi [1 ]
Taguchi, Hiroshi [1 ]
Watanabe, Yoshiaki [1 ]
Shinohara, Nobuo [2 ]
Ishikawa, Masayori [3 ]
Shirato, Hiroki [1 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Renal & Genitourinary Surg, Sapporo, Hokkaido 0608638, Japan
[3] Hokkaido Univ Hosp, Dept Med Phys, Sapporo, Hokkaido 060, Japan
关键词
adrenal gland; kidney; organ motion; radiotherapy;
D O I
10.1016/j.radonc.2008.03.013
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the three-dimensional movement of internal fiducial markers near the adrenal tumors using a real-time tumor-tracking radiotherapy (RTRT) system and to examine the feasibility of high-dose hypofractionated radiotherapy for the adrenal tumors. Materials and methods: The subjects considered in this study were 10 markers of the 9 patients treated with RTRT. A total of 72 days in the prone position and 61 treatment days in the supine position for nine of the 10 markers were analyzed. All but one patient were prescribed 48 Gy in eight fractions at the isocenter. Results: The average absolute amplitude of the marker movement in the prone position was 6.1 +/- 4.4 mm (range 2.3-14.4), 11.1 +/- 7.1 mm (3.5-25.2), and 7.0 +/- 3.5 mm (3.9-12.5) in the left-right (LR), craniocaudal (CC), and anterior-posterior (AP) directions, respectively. The average absolute amplitude in the supine position was 3.4 +/- 2.9 mm (0.6-9.1), 9.9 +/- 9.8 mm (1.1-27.1), and 5.4 +/- 5.2 mm (1.7-26.6) in the LR, CC, and AP directions, respectively. Of the eight markers, which were examined in both the prone and supine positions, there was no significant difference in the average absolute amplitude between the two positions. No symptomatic adverse effects were observed within the median follow-up period of 16 months (range 5-21 months). The actuarial freedom-from-local-progression rate was 100% at 12 months. Conclusions: Three-dimensional motion of a fiducial marker near the adrenal tumors was detected. Hypofractionated RTRT for adrenal tumors was feasible for patients with metastatic tumors. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:418 / 424
页数:7
相关论文
共 50 条
  • [21] Feasibility study of real-time tumor-tracking radiotherapy for adrenal tumors: Three-dimensional movement of internal fiducial gold markers measured in supine and prone patient positions
    Katoh, N.
    Onimaru, R.
    Shimizu, S.
    Abo, D.
    Sakuhara, Y.
    Taguchi, H.
    Osaka, Y.
    Gerard, B.
    Ishikawa, M.
    Shirato, H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S675 - S675
  • [22] Histopathologic consideration of fiducial gold markers inserted for real-time tumor-tracking radiotherapy against lung cancer
    Imura, Mikado
    Yamazaki, Koichi
    Kubota, Kanako C.
    Itoh, Tomoo
    Onimaru, Rikiya
    Cho, Yasushi
    Hida, Yasuhiro
    Kaga, Kichizo
    Onodera, Yuya
    Ogura, Shigeaki
    Dosaka-Akita, Hirotoshi
    Shirato, Hiroki
    Nishimura, Masaharu
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02): : 382 - 384
  • [23] Evaluation of Tracking Accuracy Using Synthetic Color Fluoroscopic Images Based On the Deep Learning for Real-Time Tumor-Tracking Radiotherapy
    Shiinoki, T.
    Yuasa, Y.
    Fujimoto, K.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E124 - E124
  • [24] Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy
    Shirato, H
    Suzuki, K
    Sharp, GC
    Fujita, K
    Onimaru, R
    Fujino, M
    Kato, N
    Osaka, Y
    Kinoshita, R
    Taguchi, H
    Onodera, S
    Miyasaka, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (04): : 1229 - 1236
  • [25] A Robust Tracking Algorithm for Implanted Marker of Fluoroscopic Images in a Real-Time Tumor-Tracking System
    Miyazaki, K.
    Fuji, Y.
    Umekawa, T.
    Yamada, T.
    Fujii, T.
    Miyamoto, N.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E473 - E473
  • [26] Intercepting radiotherapy using a real-time tumor-tracking radiotherapy system for highly selected patients with hepatocellular carcinoma unresectable with other modalities
    Taguchi, Hiroshi
    Sakuhara, Yusuke
    Hige, Shuhei
    Kitamura, Kei
    Osaka, Yasuhiro
    Abo, Daisuke
    Uchida, Daichi
    Sawada, Akihiro
    Kamiyama, Toshiya
    Shimizu, Tadashi
    Shirato, Hiroki
    Miyasaka, Kazuo
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (02): : 376 - 380
  • [27] Patient-specific respiratory motion management using lung tumors vs fiducial markers for real-time tumor-tracking stereotactic body radiotherapy
    Tanabe, Yoshinori
    Kiritani, Michiru
    Deguchi, Tomomi
    Hira, Nanami
    Tomimoto, Syouta
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 25
  • [28] Treatment outcomes of stereotactic body radiation therapy using a real-time tumor-tracking radiotherapy system for hepatocellular carcinomas
    Uchinami, Yusuke
    Katoh, Norio
    Abo, Daisuke
    Taguchi, Hiroshi
    Yasuda, Koichi
    Nishioka, Kentaro
    Soyama, Takeshi
    Morita, Ryo
    Miyamoto, Naoki
    Suzuki, Ryusuke
    Sho, Takuya
    Nakai, Masato
    Ogawa, Koji
    Kakisaka, Tatsuhiko
    Orimo, Tatsuya
    Kamiyama, Toshiya
    Shimizu, Shinichi
    Aoyama, Hidefumi
    [J]. HEPATOLOGY RESEARCH, 2021, 51 (08) : 870 - 879
  • [29] Baseline Shift of Intrafractional Lung Tumor Motion in Real-Time Tumor-Tracking Radiation Therapy
    Takao, S.
    Miyamoto, N.
    Matsuura, T.
    Shimizu, S.
    Onimaru, R.
    Katoh, N.
    Inoue, T.
    Shirato, H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S67 - S67
  • [30] A motion-compensated image filter for low-dose fluoroscopy in a real-time tumor-tracking radiotherapy system
    Miyamoto, Naoki
    Ishikawa, Masayori
    Sutherland, Kenneth
    Suzuki, Ryusuke
    Matsuura, Taeko
    Toramatsu, Chie
    Takao, Seishin
    Nihongi, Hideaki
    Shimizu, Shinichi
    Umegaki, Kikuo
    Shirato, Hiroki
    [J]. JOURNAL OF RADIATION RESEARCH, 2015, 56 (01) : 186 - 196