A motion-compensated image filter for low-dose fluoroscopy in a real-time tumor-tracking radiotherapy system

被引:9
|
作者
Miyamoto, Naoki [1 ]
Ishikawa, Masayori [1 ]
Sutherland, Kenneth [1 ]
Suzuki, Ryusuke [2 ]
Matsuura, Taeko [1 ]
Toramatsu, Chie [2 ]
Takao, Seishin [1 ]
Nihongi, Hideaki [1 ]
Shimizu, Shinichi [3 ]
Umegaki, Kikuo [4 ]
Shirato, Hiroki [3 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Med Phys, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ Hosp, Dept Med Phys, Sapporo, Hokkaido 0608648, Japan
[3] Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[4] Hokkaido Univ, Grad Sch Med, Div Quantum Sci & Engn, Kita Ku, Sapporo, Hokkaido 0608638, Japan
基金
日本学术振兴会;
关键词
respiratory-gated radiotherapy; real-time tracking; respiratory motion; image processing; motion compensation; imaging dose; RESPIRATORY MOTION; DIGITAL MAMMOGRAPHY; GUIDED RADIOTHERAPY; PREDICTION; QUALITY;
D O I
10.1093/jrr/rru069
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In the real-time tumor-tracking radiotherapy system, a surrogate fiducial marker inserted in or near the tumor is detected by fluoroscopy to realize respiratory-gated radiotherapy. The imaging dose caused by fluoroscopy should be minimized. In this work, an image processing technique is proposed for tracing a moving marker in low-dose imaging. The proposed tracking technique is a combination of a motion-compensated recursive filter and template pattern matching. The proposed image filter can reduce motion artifacts resulting from the recursive process based on the determination of the region of interest for the next frame according to the current marker position in the fluoroscopic images. The effectiveness of the proposed technique and the expected clinical benefit were examined by phantom experimental studies with actual tumor trajectories generated from clinical patient data. It was demonstrated that the marker motion could be traced in low-dose imaging by applying the proposed algorithm with acceptable registration error and high pattern recognition score in all trajectories, although some trajectories were not able to be tracked with the conventional spatial filters or without image filters. The positional accuracy is expected to be kept within +/- 2 mm. The total computation time required to determine the marker position is a few milliseconds. The proposed image processing technique is applicable for imaging dose reduction.
引用
收藏
页码:186 / 196
页数:11
相关论文
共 50 条
  • [1] Motion Adaptive Image Filter for Low Dose X-Ray Fluoroscopy in the Real-Time Tumor-Tracking Radiotherapy System
    Miyamoto, N.
    Ishikawa, M.
    Sutherland, K.
    Suzuki, R.
    Matsuura, T.
    Takao, S.
    Toramatsu, C.
    Nihongi, H.
    Shimizu, S.
    Onimaru, R.
    Umegaki, K.
    Shirato, H.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3661 - 3662
  • [2] Organ motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy
    Shirato, Hiroki
    Shimizu, Shinichi
    Kitamura, Kei
    Onimaru, Rikiya
    [J]. INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2007, 12 (01) : 8 - 16
  • [3] Organ motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy
    Hiroki Shirato
    Shinichi Shimizu
    Kei Kitamura
    Rikiya Onimaru
    [J]. International Journal of Clinical Oncology, 2007, 12 : 8 - 16
  • [4] Evaluation of Time Delay and Fluoroscopic Dose in a New Real-Time Tumor-Tracking Radiotherapy System
    Kitagawa, Masayasu
    Hirosawa, Ayaka
    Takemura, Akihiro
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 487 - 491
  • [5] Optimization of fluoroscopy parameters using pattern matching prediction in the real-time tumor-tracking radiotherapy system
    Miyamoto, Naoki
    Ishikawa, Masayori
    Bengua, Gerard
    Sutherland, Kenneth
    Suzuki, Ryusuke
    Kimura, Suguru
    Shimizu, Shinichi
    Onimaru, Rikiya
    Shirato, Hiroki
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (15): : 4803 - 4813
  • [6] Improvement of tracking accuracy and stability by recursive image processing in real-time tumor-tracking radiotherapy system
    Miyamoto, Naoki
    Sutherland, Kenneth
    Suzuki, Ryusuke
    Matsuura, Taeko
    Toramatsu, Chie
    Takao, Seishin
    Nihongi, Hideaki
    Kinoshita, Rumiko
    Shimizu, Shinichi
    Onimaru, Rikiya
    Umegaki, Kikuo
    Shirato, Hiroki
    Ishikawa, Masayori
    [J]. MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [7] Fluctuation in speed and amplitude of lung tumor motion detected by real-time tumor-tracking radiotherapy system
    Onodeara, S
    Fujino, M
    Fujita, K
    Onimaru, R
    Aoyama, H
    Sharp, G
    Shirato, H
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 78 : S86 - S87
  • [8] Physical aspects of a real-time tumor-tracking system for gated radiotherapy
    Shirato, H
    Shimizu, S
    Kunieda, T
    Kitamura, K
    van Herk, M
    Kagei, K
    Nishioka, T
    Hashimoto, S
    Fujita, K
    Aoyama, H
    Tsuchiya, K
    Kudo, K
    Miyasaka, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (04): : 1187 - 1195
  • [9] Real-time tumor-tracking radiotherapy for adrenal tumors
    Katoh, Norio
    Onimaru, Rikiya
    Sakuhara, Yusuke
    Abo, Daisuke
    Shimizu, Shinichi
    Taguchi, Hiroshi
    Watanabe, Yoshiaki
    Shinohara, Nobuo
    Ishikawa, Masayori
    Shirato, Hiroki
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 87 (03) : 418 - 424
  • [10] Feasibility of synchronization of real-time tumor-tracking radiotherapy and intensity-modulated radiotherapy from viewpoint of excessive dose from fluoroscopy
    Shirato, H
    Oita, M
    Fujita, K
    Watanabe, Y
    Miyasaka, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : 335 - 341