Towards Robust Blood Pressure Estimation From Pulse Wave Velocity Measured by Photoplethysmography Sensors

被引:18
|
作者
Byfield, Richard [1 ]
Miller, Morgan [1 ]
Miles, Jonathan [1 ]
Guidoboni, Giovanna [2 ,3 ]
Lin, Jian [1 ,2 ]
机构
[1] Univ Missouri, Dept Mech & Aerosp Engn, Columbia, MO 65211 USA
[2] Univ Missouri, Dept Elect Engn & Comp Sci, Columbia, MO 65211 USA
[3] Univ Missouri, Dept Math, Columbia, MO 65211 USA
关键词
Sensors; Feature extraction; Electrocardiography; Monitoring; Blood; Pulse measurements; Pressure measurement; Blood pressure; photoplethysmography; pulse wave velocity; machine learning; PPG; RISK; ECG;
D O I
10.1109/JSEN.2021.3134890
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years, advances in biosensing devices have greatly increased the ability of sensing human biological vital signs. These advances have allowed physicians to better assess the health status of patients. Among them, blood pressure (BP) sensing has been the dominant one, showing the most potential for growth. Despite much progress, a rapid, robust, and easy-accessed way for BP sensing is still much needed for the emerging point-of-care market. To tackle this challenge, in this paper, we present a BP measurement unit that is developed based on two photoplethysmography (PPG) sensors from which pulse wave velocity (PWV) of blood flow can be derived. A robust time difference of collected two subsequent PPG waveforms between two heartbeats was used to calculate PWV. The systolic and diastolic BPs from 26 participants were estimated by using the derived PWV as the input of machine learning (ML) models. Upon testing multiple ML models, the Gaussian process regressor achieved the highest R-2 score of >0.88 and >0.62 for the systolic BP and diastolic BP, respectively. These R-2 scores are among the best that can be achieved with state-of-art non-invasive BP measurement devices. This work demonstrates that PPG-based sensors for PWV and BP estimation, combined with ML, have a great potential of becoming a complementary way to measure biological vital signs.
引用
收藏
页码:2475 / 2483
页数:9
相关论文
共 50 条
  • [21] Parametric estimation of pulse arrival time: a robust approach to pulse wave velocity
    Sola, Josep
    Vetter, Rolf
    Renevey, Philippe
    Chetelat, Olivier
    Sartori, Claudio
    Rimoldi, Stefano F.
    PHYSIOLOGICAL MEASUREMENT, 2009, 30 (07) : 603 - 615
  • [22] Robust modelling of arterial blood pressure reconstruction from photoplethysmography
    Pan, Jiating
    Liang, Lishi
    Liang, Yongbo
    Tang, Qunfeng
    Chen, Zhencheng
    Zhu, Jianming
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [23] A Fast Multimodal Ectopic Beat Detection Method Applied for Blood Pressure Estimation Based on Pulse Wave Velocity Measurements in Wearable Sensors
    Pflugradt, Maik
    Geissdoerfer, Kai
    Goernig, Matthias
    Orglmeister, Reinhold
    SENSORS, 2017, 17 (01)
  • [24] Basic Concepts: Central Blood Pressure, Pulse Wave Reflections, and Pulse Wave Velocity
    Weber, T.
    JOURNAL FUR HYPERTONIE, 2010, 14 (02): : 9 - 13
  • [25] Pulse Arrival Time Segmentation Into Cardiac and Vascular Intervals - Implications for Pulse Wave Velocity and Blood Pressure Estimation
    Beutel, Fabian
    Van Hoof, Chris
    Rottenberg, Xavier
    Reesink, Koen
    Hermeling, Evelien
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (09) : 2810 - 2820
  • [26] PulseLab: An Integrated and Expandable Toolbox for Pulse Wave Velocity-based Blood Pressure Estimation
    Wang, Weinan
    Mohseni, Pedram
    Kilgore, Kevin
    Najafizadeh, Laleh
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 5654 - 5657
  • [27] EVALUATION OF DEPENDENCE OF AGE AND PERIPHERAL BLOOD PRESSURE IN TWO PULSE WAVE VELOCITY ESTIMATION METHODS
    Vilela Martin, Jose F.
    Vieira da Silva, Marco A.
    Silva de Oliveira, Ana Paula
    Silva Queiroz, Ana Carolina
    Paz Landim, Manoel I.
    Yugar-Toledo, Juan C.
    Lopes, Valquiria Silva
    Fernandes, Leticia A. Barufi
    Uyemura, Jessica Rodrigues
    Polegati, Aleandra
    Cosenso-Martin, Luciana N.
    JOURNAL OF HYPERTENSION, 2023, 41 : E266 - E267
  • [28] Robust blood pressure estimation from finger photoplethysmography using age-dependent linear models
    Xing, Xiaoman
    Ma, Zhimin
    Zhang, Mingyou
    Gao, Xi
    Li, Ying
    Song, Mingxuan
    Dong, Wen-Fei
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (02)
  • [29] Estimation of central pulse wave velocity from radial pulse wave analysis
    Yao, Yang
    Zhou, Shuran
    Alastruey, Jordi
    Hao, Liling
    Greenwald, Stephen E.
    Zhang, Yuelan
    Xu, Lin
    Xu, Lisheng
    Yao, Yudong
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 219
  • [30] Blood pressure estimation by using pulse wave sensor
    Suzuki, Arata
    Tsuji, Yoshiki
    Ue, Mizuki
    Ryu, Kazuteru
    Transactions of Japanese Society for Medical and Biological Engineering, 2014, 52