Robust blood pressure estimation from finger photoplethysmography using age-dependent linear models

被引:16
|
作者
Xing, Xiaoman [1 ]
Ma, Zhimin [2 ]
Zhang, Mingyou [3 ]
Gao, Xi [2 ]
Li, Ying [4 ]
Song, Mingxuan [5 ]
Dong, Wen-Fei [6 ]
机构
[1] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Dept Med Imaging, Suzhou, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Dept Endocrinol, Affiliated Suzhou Sci & Technol Town Hosp, Suzhou, Jiangsu, Peoples R China
[3] Jilin Univ, Hosp 1, Cardiovasc Dept, Changchun, Jilin, Peoples R China
[4] Nanjing Med Univ, Affiliated Suzhou Sci & Technol Town Hosp, Cardiovasc Dept, Suzhou, Jiangsu, Peoples R China
[5] Suzhou GK Med Co Ltd, Suzhou 215163, Jiangsu, Peoples R China
[6] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Nanobiomed Diagnost Ctr, Suzhou, Jiangsu, Peoples R China
关键词
photoplethysmography; blood pressure; multiple linear regression; ARTERIAL STIFFNESS; HYPERTENSION; PPG; INDEX;
D O I
10.1088/1361-6579/ab755d
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: This work aims to develop an efficient and robust age-dependent multiple linear regression (MLR) model to estimate blood pressure (BP) from a single-source photoplethysmography (PPG) and biometrics, which could be embedded in the microcontroller of pulse oximeters. Approach: Hemodynamic features were extracted from the PPG signal using its waveform, derivatives, and biometrics. Whole-based, feature-based, and fusion models were evaluated and compared for different age groups. Their performance was tested using 1086 subjects with a leave-one-subject-out cross-validation. The improvement by adding biometrics and the long-term calibration effect were investigated in detail. The relative importance of each feature was compared between different age groups and the implication was discussed. Main results: The fusion model achieved the best performance in subjects with well-defined PPG features, whereas the feature-based method was better suited for subjects with damped signals. Adding age significantly improved both systolic BP (SBP) and diastolic BP (DBP) estimation accuracy for older subjects (> 50 years old) with well-defined features, while it only improved diastolic BP accuracy for older subjects with damped signals. For younger subjects (<= 50 years old), the contribution of age was very small. A simple subtraction of subject-specific calibration factors significantly reduced biometric-related errors, which also improved the linearity of BP estimation. The relative importance analysis of input features suggests that separate models are indeed necessary for different age groups with different signal qualities, especially for DBP estimation in older subjects. Significance: This study shows a reasonable BP estimation accuracy with age-dependent MLR models, which may help to equip current pulse oximeters with additional functionalities.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Blood Pressure Estimation Based on Photoplethysmography: Finger Versus Wrist
    Paliakaite, Birute
    Charlton, Peter H.
    Rapalis, Andrius
    Plusciauskaite, Vilma
    Piartli, Povilas
    Kaniusas, Eugenijus
    Marozas, Vaidotas
    2021 COMPUTING IN CARDIOLOGY (CINC), 2021,
  • [2] Estimation of Blood Pressure Using Photoplethysmography on the Wrist
    Song, S. H.
    Cho, J. S.
    Oh, H. S.
    Lee, J. S.
    Kim, I. Y.
    CINC: 2009 36TH ANNUAL COMPUTERS IN CARDIOLOGY CONFERENCE, 2009, 36 : 741 - 744
  • [3] Arterial blood pressure feature estimation using photoplethysmography
    Zadi, Armin Soltan
    Alex, Raichel
    Zhang, Rong
    Watenpaugh, Donald E.
    Behbehani, Khosrow
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 102 : 104 - 111
  • [4] Blood Pressure Estimation Using Explainable Deep-Learning Models Based on Photoplethysmography
    Perdereau, Jade
    Chamoux, Thibaut
    Gayat, Etienne
    Le Gall, Arthur
    Vallee, Fabrice
    Cartailler, Jerome
    Joachim, Jona
    ANESTHESIA AND ANALGESIA, 2025, 140 (01): : 119 - 128
  • [5] Feature Learning for Blood Pressure Estimation from Photoplethysmography
    Aguet, Clementine
    Van Zaen, Jerome
    Jorge, Joao
    Proenca, Martin
    Bonnier, Guillaume
    Frossard, Pascal
    Lemay, Mathieu
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 463 - 466
  • [6] Towards Robust Blood Pressure Estimation From Pulse Wave Velocity Measured by Photoplethysmography Sensors
    Byfield, Richard
    Miller, Morgan
    Miles, Jonathan
    Guidoboni, Giovanna
    Lin, Jian
    IEEE SENSORS JOURNAL, 2022, 22 (03) : 2475 - 2483
  • [7] Robust modelling of arterial blood pressure reconstruction from photoplethysmography
    Pan, Jiating
    Liang, Lishi
    Liang, Yongbo
    Tang, Qunfeng
    Chen, Zhencheng
    Zhu, Jianming
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [8] Longitudinal age-dependent effect on systolic blood pressure
    Bonnie R Joubert
    Guoqing Diao
    Danyu Lin
    Kari E North
    Nora Franceschini
    BMC Proceedings, 3 (Suppl 7)
  • [9] ARE THE CIRCADIAN BLOOD-PRESSURE VARIATIONS AGE-DEPENDENT
    GROSSMANN, M
    LASKE, V
    BAUMGART, P
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1991, 20 (10) : 501 - 502
  • [10] Assessing heart rate and blood pressure estimation from image photoplethysmography using a digital blood pressure meter
    Trirongjitmoah, Suchin
    Promking, Arphorn
    Kaewdang, Khanittha
    Phansiri, Nisarut
    Treeprapin, Kriengsak
    HELIYON, 2024, 10 (05)