Feasibility of repeat transradial access for neuroendovascular procedures

被引:32
|
作者
Chen, Stephanie H. [1 ]
Brunet, Marie-Christine [1 ]
Sur, Samir [1 ]
Yavagal, Dileep R. [2 ]
Starke, Robert M. [1 ]
Peterson, Eric C. [1 ]
机构
[1] Univ Miami, Sch Med, Dept Neurol Surg, Miami, FL 33136 USA
[2] Univ Miami, Neurol & Neurosurg, Miami, FL USA
关键词
transradial approach; radial access; angiography; endovascular; repeat; radial artery occlusion; neurovascular; neurointervention; RADIAL ARTERY-OCCLUSION; CORONARY-ANGIOGRAPHY; FEMORAL ACCESS; CATHETERIZATION; INTERVENTION; IMPACT; FAILURE;
D O I
10.1136/neurintsurg-2019-015438
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Introduction Transradial artery access (TRA) for cerebrovascular angiography is increasing due to decreased access site complications and overwhelming patient preference. While interventional cardiologists have reported up to 10 successive TRA procedures via the same radial access site, this is the first study examining successive use of the same artery for repeat procedures in neurointerventional procedures.1 Methods We reviewed our prospective institutional database for all patients who underwent a transradial neurointerventional procedure between 2015 and 2019. Index procedures were defined as procedures performed via TRA after which there was a second TRA procedure attempted. Reasons for conversion to a transfemoral approach (TFA) for subsequent procedures were identified. Results 104 patients underwent 237 procedures (230 TRA, 7 TFA). 97 patients underwent >= 2 TRA procedures, 20 patients >3, four patients >4, three patients >5, and two patients >6 TRA procedures. The success rate was 94.7% (126/133) with 52% (66/126) of successive procedures performed via the same radial access site (snuffbox vs antebrachial) while the alternate radial artery segment was used for access in 48% (60/126) of subsequent procedures. There were seven (5.3%) cases requiring crossover to TFA, six cases for radial artery occlusion (RAO) and one for radial artery narrowing. Conclusion Successive TRA is both technically feasible and safe for neuroendovascular procedures in up to six procedures. The low failure rate (5.3%) was primarily due to RAO. Thus, even without clinical consequences, strategies to minimize RAO should be optimized for patients to continue to benefit from TRA in future procedures.
引用
收藏
页码:431 / 434
页数:4
相关论文
共 50 条
  • [41] Transradial Access and Radiation Exposure in Diagnostic and Interventional Coronary Procedures
    Rigattieri, Stefano
    Sciahbasi, Alessandro
    Drefahl, Sven
    Mussino, Eleonora
    Cera, Maria
    Di Russo, Cristian
    Fedele, Silvio
    Pugliese, Francesco Rocco
    JOURNAL OF INVASIVE CARDIOLOGY, 2014, 26 (09): : 469 - 474
  • [42] Bivalirudin and Transradial Access - The End of the Bleeding Era for Catheterization Procedures?
    Badheka, Apurva
    Cohen, Mauricio G.
    JOURNAL OF INVASIVE CARDIOLOGY, 2011, 23 (03): : 105 - 106
  • [43] Safety and Feasibility of Transradial Access for Noncoronary and Peripheral Vascular Interventions
    Zia, Saqib
    Singh, Kuldeep
    Juneja, Amandeep
    Schor, Jonathan
    Deitch, Jonathan
    ANNALS OF VASCULAR SURGERY, 2018, 53 : 255 - 261
  • [44] Transradial access through the anatomical snuffbox: Results of a feasibility study
    Tsigkas, Grigorios
    Moulias, Athanasios
    Papageorgiou, Aggeliki
    Ntouvas, Ioannis
    Grapsas, Nikolaos
    Despotopoulos, Stefanos
    Apostolos, Anastasios
    Papanikolaou, Amalia
    Smaili, Kalliopi
    Vasilagkos, Georgios
    Davlouros, Periklis
    Hahalis, Georgios
    HELLENIC JOURNAL OF CARDIOLOGY, 2021, 62 (03) : 201 - 205
  • [45] Safety and Feasibility of Transradial Access for Visceral Interventions in Patients with Thrombocytopenia
    J. J. Titano
    D. M. Biederman
    B. S. Marinelli
    R. S. Patel
    E. Kim
    N. E. Tabori
    F. S. Nowakowski
    R. A. Lookstein
    A. M. Fischman
    CardioVascular and Interventional Radiology, 2016, 39 : 676 - 682
  • [46] Safety and Feasibility of Transradial Access for Visceral Interventions in Patients with Thrombocytopenia
    Titano, J. J.
    Biederman, D. M.
    Marinelli, B. S.
    Patel, R. S.
    Kim, E.
    Tabori, N. E.
    Nowakowski, F. S.
    Lookstein, R. A.
    Fischman, A. M.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (05) : 676 - 682
  • [47] The utility of DynaCT in neuroendovascular procedures
    Heran, NS
    Song, JK
    Mamba, K
    Smith, W
    Niimi, Y
    Berenstein, A
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (02) : 330 - 332
  • [48] Techniques and Devices in Neuroendovascular Procedures
    Liebman, Kenneth M.
    Severson, Meryl A., III
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2009, 20 (03) : 315 - +
  • [49] Transradial approach for neuroendovascular surgery of intracranial vascular lesions
    Eskioglu, E
    Burry, MV
    Mericle, RA
    JOURNAL OF NEUROSURGERY, 2004, 101 (05) : 767 - 769
  • [50] Effectiveness and Safety of Left Distal Transradial Access in Coronary Procedures in the Caribbean
    Seecheran, Naveen A.
    Quert, Abel Y. Leyva
    Seecheran, Valmiki K.
    Seecheran, Rajeev, V
    Katwaroo, Arun
    Jagdeo, Cathy-Lee
    Rafeeq, Salma
    Ramcharan, Priya
    Peram, Lakshmipathi
    Ramlal, Ravi
    Ramlackhansingh, Anil
    Giddings, Stanley
    Sandy, Sherry
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (02)