Comparative study of hybrid ground source heat pump in cooling and heating dominant climates

被引:22
|
作者
Bina, Saeid Mohammadzadeh [1 ]
Fujii, Hikari [1 ]
Tsuya, Shunsuke [1 ]
Kosukegawa, Hiroyuki [1 ]
机构
[1] Akita Univ, Grad Sch Engn & Resource Sci, Akita, Japan
关键词
GSHP; Hybrid system; Heat pump; GHE; TRNSYS; Long-term; UNDERGROUND THERMAL IMBALANCE; PERFORMANCE; SYSTEM; FEASIBILITY; EXCHANGERS; GSHP;
D O I
10.1016/j.enconman.2021.115122
中图分类号
O414.1 [热力学];
学科分类号
摘要
The ground source heat pump system (GSHP) has been an accepted technology to provide energy efficient and renewable air conditioning to the buildings. However, imbalanced heating and cooling load during the winter and summers especially in the regions with heating and cooling dominant climates may degrade the performance of the system over a long-term operation. Hybrid GSHP system which uses supplemental energy sources such as solar panel or cooling tower can balance the imposing load on the ground heat exchanger (GHE) and benefits the system by minimizing the GHE length in short-term and improves the overall performance in long-term. This research presents a study of application of hybrid GSHP system with an intention to compare its applicability in the regions with dominant heating and cooling loads. In this study, a student office and an actual heat pump system in Akita City, northern Japan was modeled in TRNSYS software and was validated using in-situ measured data. The hybrid system which coupled with a supplemental heating and cooling source devices was simulated to test its viability for the different heating and cooling loads in different regions within the country. The results revealed that hybrid system plays an effective role in both climates to balance the load on GHE, keeps constant the soil temperature, and consequently improves the long-term performance. Moreover, in short-term, it can reduce the GHE length and decrease drilling cost based on the meteoroidal condition of the region such as solar radiation. For instance, the GHE length was reduced to around half in cooling dominant region using cooling tower, while it was negligible in heating dominant region.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Performance optimization of a hybrid ground source heat pump with the parallel configuration of a ground heat exchanger and a supplemental heat rejecter in the cooling mode
    Park, Honghee
    Lee, Joo Seoung
    Kim, Wonuk
    Kim, Yongchan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (06): : 1537 - 1546
  • [32] Two-stage air-source heat pump for residential heating and cooling applications in northern US climates
    Bertsch, Stefan S.
    Groll, Eckhard A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07): : 1282 - 1292
  • [33] Design of Residential Ground Source Heat Pump Systems for Heating Dominated Climates - Trade-Offs Between Ground Heat Exchanger Design and Supplementary Electric Resistance Heating
    Gehlin, Signhild E. A.
    Spitler, Jeffrey D.
    ASHRAE TRANSACTIONS 2014, VOL 120, PT 1, 2014, 120
  • [34] Research of combined heating and cooling by solar ground-source heat pump and PCM thermal storage
    Wu, Li-xia
    Zheng, Mao-yu
    Solar Engineering 2005, 2006, : 275 - 282
  • [35] Adjustable performance analysis of combined cooling heating and power system integrated with ground source heat pump
    Wang, Jiangjiang
    Chen, Yuzhu
    Dou, Chao
    Gao, Yuefen
    Zhao, Zheng
    ENERGY, 2018, 163 : 475 - 489
  • [36] Startup characteristics of the ground source heat pump in the mode of heating
    Li, Y.D.
    Zhang, X.
    Zhou, Y.S.
    Chen, P.L.
    Nuantong Kongtiao/HV & AC, 2001, 31 (01):
  • [37] Application of ground-heat-source water thermal-storage with a heat-pump cooling and heating system
    Lim, K. B.
    Lee, S. H.
    Lee, C. H.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2010, 224 (E1) : 73 - 78
  • [38] GROUND-WATER HEAT PUMP SYSTEMS FOR HEATING AND COOLING OF BUILDINGS
    MEYERS, AC
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (01): : 55 - 55
  • [39] Simple index for onsite operation management of ground source heat pump systems in cooling-dominant regions
    Kindaichi, Sayaka
    Nishina, Daisaku
    RENEWABLE ENERGY, 2018, 127 : 182 - 194
  • [40] A Study of the Ground Source Heat Pump System in Shanghai Minhang Archives in the Heating Mode
    Yu, Xin
    Wang, Ruzhu
    Zhai, Xiaoqiang
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 687 - 693