In-Line Monitoring of Coating Thickness of Pharmaceutical Tablets during Production Scale Film Coating by Terahertz Imaging

被引:0
|
作者
May, Robert K. [1 ]
Evans, Michael J. [2 ]
Zhong, Shuncong [3 ]
Warr, Ian [4 ]
Gladden, Lynn F. [1 ]
Shen, Yaochun [3 ]
Zeitler, J. Axel [1 ]
机构
[1] Univ Cambridge, Dept Chem Engn & Biotechnol, Cambridge CB2 3RA, England
[2] TeraView Ltd, Cambridge CB4 0WS, England
[3] Univ Liverpool, Dept Elect & Elect Engn, Liverpool L69 3GJ, Merseyside, England
[4] Oystar Mannesty, Liverpool L34 9JS, Merseyside, England
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present preliminary results from in-line Terahertz pulsed imaging (TPI) measurements of coating thickness on pharmaceutical tablets made during production-scale film coating. Results of these real-time TPI measurements are compared to those from off-line TPI measurements, as well as weight-gain measurements made on sample tablets removed at discrete time-intervals during production. The results, and their repeatability, demonstrate that real-time monitoring of pharmaceutical tablet coating is not only possible but provides substantially more information than the standard quality control method.
引用
收藏
页数:2
相关论文
共 50 条
  • [21] Feasibility of In-line monitoring of critical coating quality attributes via OCT: Thickness, variability, film homogeneity and roughness
    Sacher, Stephan
    Peter, Anna
    Khinast, Johannes G.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS-X, 2021, 3
  • [22] Determining the effect of photodegradation on film coated nifedipine tablets with, terahertz based coating thickness measurements
    Odani, Noritaka
    Mohan, Shikhar
    Kato, Eiji
    Feng, Hanzhou
    Li, Yi
    Hossain, Md Nayeem
    Drennen, James K., III
    Anderson, Carl A.
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2019, 145 : 35 - 41
  • [23] Quantitative analysis of visible surface defect risk in tablets during film coating using terahertz pulsed imaging
    Niwa, Masahiro
    Hiraishi, Yasuhiro
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2014, 461 (1-2) : 342 - 350
  • [24] Quantifying Pharmaceutical Film Coating with Optical Coherence Tomography and Terahertz Pulsed Imaging: An Evaluation
    Lin, Hungyen
    Dong, Yue
    Shen, Yaochun
    Zeitler, J. Axel
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2015, 104 (10) : 3377 - 3385
  • [25] Impact of Processing Conditions on Inter-tablet Coating Thickness Variations Measured by Terahertz In-Line Sensing
    Lin, Hungyen
    May, Robert K.
    Evans, Michael J.
    Zhong, Shuncong
    Gladden, Lynn F.
    Shen, Yaochun
    Zeitler, J. Axel
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2015, 104 (08) : 2513 - 2522
  • [26] Optical in situ film thickness monitoring in coating systems
    Gossi, Dominik
    VAKUUM IN FORSCHUNG UND PRAXIS, 2005, 17 (04) : 186 - 189
  • [27] Real-time Data Processing for In-line Monitoring of a Pharmaceutical Coating Process by Optical Coherence Tomography
    Markl, Daniel
    Ziegler, Jakob
    Hannesschlaeger, Guenther
    Sacher, Stephan
    Buchsbaum, Andreas
    Leitner, Michael
    Khinast, Johannes G.
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE IV, 2014, 9129
  • [28] An in-line optical fiber refractometer with porous thin film coating
    Lee, Dongwen
    Yang, Minghong
    Qi, Chongjie
    Dai, Jixiang
    Wen, Xiaoyam
    Xiea, Weijing
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 602 - 605
  • [29] A study on the applicability of in-line measurements in the monitoring of the pellet coating process
    Hudovornik, Grega
    Korasa, Klemen
    Vrecer, Franc
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2015, 75 : 160 - 168
  • [30] In-line monitoring of coating processes by near infrared reflection spectroscopy
    Leibniz Institute of Surface Modification , Permoserstr. 15, D-04318 Leipzig, Germany
    spectrosc eur, 2008, 6 (6-8):