Interactive MR-guided biopsies of the thyroid gland: validation of a new method

被引:3
|
作者
Kacl, GM
Bicik, I
Schonenberger, AW
Steiner, P
Romanowski, B
Debatin, JF
von Schulthess, GK
机构
[1] Univ Zurich Hosp, Dept Med Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Div Nucl Med, CH-8091 Zurich, Switzerland
关键词
thyroid; biopsy; interventional MR; MR guidance; stereotaxis; ultrasound;
D O I
10.1007/s003300050529
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to demonstrate the clinical feasibility and utility of an interactive MR-guidance system to target and biopsy thyroid lesions, and to compare resolution between ultrasound and interventional MR imaging in the evaluation of thyroid lesions. Twenty thyroid lesions of 18 patients were interactively biopsied using a 0.5-T superconducting open magnet system. Stereotactic localization of the needle and imaging was accomplished using T1-weighted gradient-recalled-echo (GRE) images. representative cytological material was retrieved in 16 of 20 lesions (benign cystic or colloid goiter: n = 14; one de Quervain's thyroiditis and one follicular neoplasia). Lesions smaller than 1.5 cm detected by ultrasound could not be visualized adequately on GRE images. Lesions smaller than 1.5 cm were successfully biopsied by ultra sound (three colloid and haemorrhagic goiters and one adenoma). Magnetic-resonance-guided interactive biopsies and positioning of non-ferromagnetic needles in the thyroid gland are technically feasible and safe. Compared with high-resolution ultrasound, lesions larger than 1.5 cm can be adequately visualized and biopsied. Magnetic-resonance-guided placement of non-ferromagnetic needles is no substitute for high-resolution ultrasound in clinical work-up of thyroid lesions.
引用
收藏
页码:1173 / 1178
页数:6
相关论文
共 50 条
  • [41] Performing MR-guided biopsies in clinical routine: factors that influence accuracy and procedure time
    Hoffmann, Rudiger
    Thomas, Christoph
    Rempp, Hansjorg
    Schmidt, Diethard
    Pereira, Philippe L.
    Claussen, Claus D.
    Clasen, Stephan
    EUROPEAN RADIOLOGY, 2012, 22 (03) : 663 - 671
  • [42] MR-guided needle aspiration biopsies of hepatic masses using a closed bore magnet
    Rofsky, NM
    Yang, BM
    Schlossberg, P
    Goldenberg, A
    Teperman, LW
    Weinreb, JC
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (04) : 633 - 637
  • [43] MR-guided core biopsies of soft tissue tumours on an open 0.23 T imager
    Parkkola, RK
    Mattila, KT
    Heikkilä, JT
    Ekfors, TO
    Komu, MES
    Vaara, T
    Aro, HT
    ACTA RADIOLOGICA, 2001, 42 (03) : 302 - 305
  • [44] Performing MR-guided biopsies in clinical routine: factors that influence accuracy and procedure time
    Rüdiger Hoffmann
    Christoph Thomas
    Hansjörg Rempp
    Diethard Schmidt
    Philippe L. Pereira
    Claus D. Claussen
    Stephan Clasen
    European Radiology, 2012, 22 : 663 - 671
  • [45] In-vitro evaluation of a novel MR-compatible cardiac bioptome catheter for MR-guided myocardial biopsies
    Sebastian A Seitz
    Sebastian M Haberkorn
    Herbert Maslanka
    Hugo A Katus
    Henning Steen
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [46] NEW NEEDLE FOR MR-GUIDED ASPIRATION CYTOLOGY OF THE HEAD AND NECK
    LUFKIN, R
    TERESI, L
    HANAFEE, W
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (02) : 380 - 382
  • [47] Interventional MR-guided neuroendoscopy: A new therapeutic option for children
    Balmer, B
    Bernays, RL
    Kollias, SS
    Yonekawa, Y
    JOURNAL OF PEDIATRIC SURGERY, 2002, 37 (04) : 668 - 672
  • [48] Laboratory prototype for experimental validation of MR-guided radiofrequency head and neck hyperthermia
    Paulides, M. M.
    Bakker, J. F.
    Hofstetter, L. W.
    Numan, W. C. M.
    Pellicer, R.
    Fiveland, E. W.
    Tarasek, M.
    Houston, G. C.
    van Rhoon, G. C.
    Yeo, D. T. B.
    Kotek, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (09): : 2139 - 2154
  • [49] Reasons for Cancellation of MR-guided Biopsies: Correlation of Patient and Lesion Characteristics with Likelihood of Biopsy Cancellation
    Tredennick, T.
    Mainiero, M. B.
    Lourenco, A. P.
    Lazarus, E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [50] Sequence evaluation for MR-guided biopsies of abdominal lesions with different sequences in low field system
    Zangos, S
    Kiefl, D
    Abolmaali, ND
    Engelmann, KS
    Schlemann, MS
    Vogl, TJ
    RADIOLOGY, 2002, 225 : 396 - 396