Interactive MR-guided biopsies of the thyroid gland: validation of a new method

被引:3
|
作者
Kacl, GM
Bicik, I
Schonenberger, AW
Steiner, P
Romanowski, B
Debatin, JF
von Schulthess, GK
机构
[1] Univ Zurich Hosp, Dept Med Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Div Nucl Med, CH-8091 Zurich, Switzerland
关键词
thyroid; biopsy; interventional MR; MR guidance; stereotaxis; ultrasound;
D O I
10.1007/s003300050529
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to demonstrate the clinical feasibility and utility of an interactive MR-guidance system to target and biopsy thyroid lesions, and to compare resolution between ultrasound and interventional MR imaging in the evaluation of thyroid lesions. Twenty thyroid lesions of 18 patients were interactively biopsied using a 0.5-T superconducting open magnet system. Stereotactic localization of the needle and imaging was accomplished using T1-weighted gradient-recalled-echo (GRE) images. representative cytological material was retrieved in 16 of 20 lesions (benign cystic or colloid goiter: n = 14; one de Quervain's thyroiditis and one follicular neoplasia). Lesions smaller than 1.5 cm detected by ultrasound could not be visualized adequately on GRE images. Lesions smaller than 1.5 cm were successfully biopsied by ultra sound (three colloid and haemorrhagic goiters and one adenoma). Magnetic-resonance-guided interactive biopsies and positioning of non-ferromagnetic needles in the thyroid gland are technically feasible and safe. Compared with high-resolution ultrasound, lesions larger than 1.5 cm can be adequately visualized and biopsied. Magnetic-resonance-guided placement of non-ferromagnetic needles is no substitute for high-resolution ultrasound in clinical work-up of thyroid lesions.
引用
收藏
页码:1173 / 1178
页数:6
相关论文
共 50 条
  • [21] MR-guided bone biopsy: Preliminary report of a new guiding method
    Ojala, R
    Sequeiros, RB
    Klemola, R
    Vahala, E
    Jyrkinen, L
    Tervonen, O
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (01) : 82 - 86
  • [22] Diagnostic yield of MR-guided liver biopsies compared with CT- and US-guided liver biopsies
    Schmidt, AJ
    Kee, ST
    Sze, DY
    Daniel, BL
    Razavi, MK
    Semba, CP
    Dake, MD
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (10) : 1323 - 1329
  • [23] MR-guided biopsies in an open-configuration MR imaging system: A case report
    Schoenenberger, AW
    Steiner, P
    Debatin, JF
    Pfammatter, T
    Kacl, GM
    RADIOLOGE, 1996, 36 (09): : 705 - 708
  • [24] MR-guided muscle biopsy: A novel technique for the collection of muscle biopsies
    Lassche, S.
    Janssen, B. H.
    Voermans, N. C.
    Futterer, J. J.
    van Engelen, B. G. M.
    NEUROMUSCULAR DISORDERS, 2014, 24 (9-10) : 799 - 799
  • [25] Evaluation of how users interface with holographic augmented reality surgical scenes: Interactive planning MR-Guided prostate biopsies
    Velazco-Garcia, Jose D.
    Navkar, Nikhil V.
    Balakrishnan, Shidin
    Younes, Georges
    Abi-Nahed, Julien
    Al-Rumaihi, Khalid
    Darweesh, Adham
    Elakkad, Mohamed S. M.
    Al-Ansari, Abdulla
    Christoforou, Eftychios G.
    Karkoub, Mansour
    Leiss, Ernst L.
    Tsiamyrtzis, Panagiotis
    Tsekos, Nikolaos V.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2021, 17 (05):
  • [26] INTERACTIVE MR-GUIDED BIOPSY IN AN OPEN-CONFIGURATION MR-IMAGING SYSTEM
    SILVERMAN, SG
    COLLICK, BD
    FIGUEIRA, MR
    KHORASANI, R
    ADAMS, DF
    NEWMAN, RW
    TOPULOS, GP
    JOLESZ, FA
    RADIOLOGY, 1995, 197 (01) : 175 - 181
  • [27] MR-GUIDED BREAST LESION LOCALIZATION - VALIDATION-STUDY
    FARRIA, DM
    GORCZYCA, DP
    DEBRUHL, ND
    SULLENBERGER, P
    SINHA, S
    BASSETT, LW
    RADIOLOGY, 1995, 197 : 461 - 461
  • [28] VALIDATION OF TCD SIGNAL ORIGIN WITH MR-GUIDED STEREOTAXIC TECHNIQUE
    RAZUMOVSKY, A
    MONSEIN, L
    NAUTA, H
    BRYAN, N
    HANLEY, D
    STROKE, 1993, 24 (03) : 515 - 515
  • [29] Validation of Catheter Segmentation for MR-Guided Gynecologic Cancer Brachytherapy
    Pernelle, Guillaume
    Mehrtash, Alireza
    Barber, Lauren
    Damato, Antonio
    Wang, Wei
    Seethamraju, Ravi Teja
    Schmidt, Ehud
    Cormack, Robert A.
    Wells, Williams
    Viswanathan, Akila
    Kapur, Tina
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2013), PT III, 2013, 8151 : 380 - 387
  • [30] MR-guided interactive procedure with a clinical C-arm system
    Lewin, JS
    Duerk, JL
    Petersilge, CA
    Lenz, G
    Williams, ML
    Haaga, JR
    RADIOLOGY, 1996, 201 : 471 - 471