Interactive MR-guided biopsies of the thyroid gland: validation of a new method

被引:3
|
作者
Kacl, GM
Bicik, I
Schonenberger, AW
Steiner, P
Romanowski, B
Debatin, JF
von Schulthess, GK
机构
[1] Univ Zurich Hosp, Dept Med Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Div Nucl Med, CH-8091 Zurich, Switzerland
关键词
thyroid; biopsy; interventional MR; MR guidance; stereotaxis; ultrasound;
D O I
10.1007/s003300050529
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to demonstrate the clinical feasibility and utility of an interactive MR-guidance system to target and biopsy thyroid lesions, and to compare resolution between ultrasound and interventional MR imaging in the evaluation of thyroid lesions. Twenty thyroid lesions of 18 patients were interactively biopsied using a 0.5-T superconducting open magnet system. Stereotactic localization of the needle and imaging was accomplished using T1-weighted gradient-recalled-echo (GRE) images. representative cytological material was retrieved in 16 of 20 lesions (benign cystic or colloid goiter: n = 14; one de Quervain's thyroiditis and one follicular neoplasia). Lesions smaller than 1.5 cm detected by ultrasound could not be visualized adequately on GRE images. Lesions smaller than 1.5 cm were successfully biopsied by ultra sound (three colloid and haemorrhagic goiters and one adenoma). Magnetic-resonance-guided interactive biopsies and positioning of non-ferromagnetic needles in the thyroid gland are technically feasible and safe. Compared with high-resolution ultrasound, lesions larger than 1.5 cm can be adequately visualized and biopsied. Magnetic-resonance-guided placement of non-ferromagnetic needles is no substitute for high-resolution ultrasound in clinical work-up of thyroid lesions.
引用
收藏
页码:1173 / 1178
页数:6
相关论文
共 50 条
  • [1] Interactive MR-guided biopsies of the thyroid gland: validation of a new method
    G. M. Kacl
    I. Bicik
    A. W. Schönenberger
    P. Steiner
    B. Romanowski
    J. F. Debatin
    G. K. von Schulthess
    European Radiology, 1998, 8 : 1173 - 1178
  • [2] Interactive percutaneous MR-guided biopsies of thyroid lesions
    Kacl, GM
    Bicik, J
    Schoenenberger, AW
    Steiner, P
    Debatin, JF
    VonSchulthess, GK
    RADIOLOGY, 1996, 201 : 450 - 450
  • [3] Interactive MR-guided biopsies before maxillofacial surgery
    Carls, FR
    Kacl, GM
    Debatin, JF
    Longerich, U
    Warnke, T
    Sailer, HF
    CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1997, 1134 : 744 - 750
  • [4] Interactive MR-guided biopsies of the maxilla and the skull base
    Kacl, GM
    Carls, FP
    Sailer, HF
    Romanowski, B
    Debatin, JF
    Schulthess, GK
    RADIOLOGY, 1997, 205 : 1644 - 1644
  • [5] MR-guided biopsies
    H.-B. Gehl
    C. Frahm
    Der Radiologe, 1998, 38 : 194 - 199
  • [6] MR-guided biopsies
    Gehl, HB
    Frahm, C
    RADIOLOGE, 1998, 38 (03): : 194 - 199
  • [7] MR BODY STEREOTAXIS - AN AID FOR MR-GUIDED BIOPSIES
    LUFKIN, R
    DUCKWILER, G
    SPICKLER, E
    TERESI, L
    CHANG, M
    ONIK, G
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (06) : 1088 - 1089
  • [8] INTERACTIVE MR-GUIDED SINUS ENDOSCOPY
    HSU, L
    JOLESZ, FA
    FRIED, MP
    RADIOLOGY, 1995, 197 : 237 - 237
  • [9] Interactive MR-guided percutaneous nephrostomy
    Hagspiel, KD
    Kandarpa, K
    Silverman, SG
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06): : 1319 - 1322
  • [10] MR-guided interventions of the prostate gland
    Zangos, S.
    Eichler, K.
    Thalhammer, A.
    Schoepf, J. U.
    Costello, P.
    Herzog, C.
    Mack, M. G.
    Vogl, T. J.
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2007, 16 (04) : 222 - 229