Multipolar radiofrequency ablation using internally cooled electrodes in ex vivo bovine liver: Correlation between volume of coagulation and amount of applied energy

被引:19
|
作者
Clasen, Stephan [1 ]
Rempp, Hansjoerg [1 ]
Schmidt, Diethard [1 ]
Schraml, Christina [1 ]
Hoffmann, Ruediger [1 ]
Claussen, Claus D. [1 ]
Pereira, Philippe L. [2 ]
机构
[1] Univ Hosp, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[2] SLK Clin Heilbronn, Clin Radiol Minimal Invas Therapies & Nucl Med, D-74078 Heilbronn, Germany
关键词
Liver; Radiofrequency ablation; Multipolar; Energy; HEPATIC-TUMORS; BIPOLAR; SIZE;
D O I
10.1016/j.ejrad.2010.10.031
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the relationship between applied energy and volume of coagulation induced by multipolar radiofrequency (RF) ablation. Methods and materials: Multipolar RF ablations (n = 80) were performed in ex vivo bovine liver. Three bipolar applicators with two electrodes located on each applicator shaft were placed in a triangular array. The power-output (75-225 W) and the distance between the different applicators (2, 3, 4, 5 cm) were systematically varied. The volume of confluent white coagulation and the amount of applied energy were assessed. Based on our experimental data the relationship between the volume of coagulation and applied energy was assessed by nonlinear regression analysis. The variability explained by the model was determined by the parameter r(2). Results: The volume of coagulation increases with higher amounts of applied energy. The maximum amount of energy was applied at a power-output of 75 W and an applicator distance of 5 cm. The corresponding maximum volume of coagulation was 324 cm3 and required an application of 453 kJ. The relationship between amount of applied energy (E) and volume (V) of coagulation can be described by the function, V = 4.39E0.7 (r(2) = 0.88). By approximation the volume of coagulation can be calculated by the linear function V = 0.61E + 40.7 (r(2) = 0.87). Conclusion: Ex vivo the relationship between volume of coagulation and amount of applied energy can be described by mathematical modeling. The amount of applied energy correlates to the volume of coagulation and may be a useful parameter to monitor multipolar RF ablation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:111 / 113
页数:3
相关论文
共 48 条
  • [1] Bipolar Radiofrequency ablation using internally cooled electrodes in ex vivo bovine liver -: Prediction of coagulation volume from applied energy
    Clasen, Stephan
    Schmidt, Diethard
    Dietz, Klaus
    Boss, Andreas
    Kroeber, Stefan M.
    Schraml, Christina
    Fritz, Jan
    Claussen, Claus D.
    Pereira, Philippe L.
    INVESTIGATIVE RADIOLOGY, 2007, 42 (01) : 29 - 36
  • [2] Multipolar radiofrequency ablation with internally cooled electrodes:: Experimental study in ex vivo bovine liver with mathernatic modeling
    Clasen, S
    Schmidt, D
    Boss, A
    Dietz, K
    Kröber, SM
    Claussen, CD
    Pereira, PL
    RADIOLOGY, 2006, 238 (03) : 881 - 890
  • [3] Radiofrequency Ablation Zones in Ex Vivo Bovine and In Vivo Porcine Livers: Comparison of the Use of Internally Cooled Electrodes and Internally Cooled Wet Electrodes
    Cha, Jihoon
    Choi, Dongil
    Lee, Min Woo
    Rhim, Hyunchul
    Kim, Young-sun
    Lim, Hyo K.
    Yoon, Jung Hwan
    Park, Cheol Keun
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (06) : 1235 - 1240
  • [4] Radiofrequency Ablation Zones in Ex Vivo Bovine and In Vivo Porcine Livers: Comparison of the Use of Internally Cooled Electrodes and Internally Cooled Wet Electrodes
    Jihoon Cha
    Dongil Choi
    Min Woo Lee
    Hyunchul Rhim
    Young-sun Kim
    Hyo K. Lim
    Jung Hwan Yoon
    Cheol Keun Park
    CardioVascular and Interventional Radiology, 2009, 32 : 1235 - 1240
  • [5] Large-volume radiofrequency ablation of ex vivo bovine liver with multiple cooled cluster electrodes
    Haemmerich, D
    Lee, FT
    Schutt, DJ
    Sampson, LA
    Webster, JG
    Fine, JP
    Mahvi, DM
    RADIOLOGY, 2005, 234 (02) : 563 - 568
  • [6] Comparison of ablation performance between dual internally cooled wet tip and conventional dual internally cooled tip radiofrequency electrodes: an experimental study in ex vivo bovine liver
    Cha, Dong Ik
    Lee, Min Woo
    Jeong, Woo Kyoung
    Ha, Sang Yun
    Ahn, Soo Hyun
    Rhim, Hyunchul
    Lim, Hyo Keun
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (01) : 332 - 340
  • [7] Comparison of Microwave Ablation and Multipolar Radiofrequency Ablation In Vivo Using Two Internally Cooled Probes
    Fan, WeiJun
    Li, Xin
    Zhang, Liang
    Jiang, Hua
    Zhang, JianLei
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : W46 - W50
  • [8] Increasing radiofrequency ablation volumes with the use of internally cooled electrodes and injected hydrochloric acid in ex vivo bovine livers
    Jiang, Xiong-Ying
    Zhang, Tian-Qi
    Li, Guo
    Gu, Yang-Kui
    Gao, Fei
    Yao, Wang
    Zhang, Yan-yang
    Huang, Jin-hua
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 35 (01) : 37 - 43
  • [9] Radiofrequency ablation of the porcine liver in vivo: Increased coagulation with an internally cooled perfusion electrode
    Lee, JM
    Han, JK
    Chang, JM
    Chung, SY
    Kim, SH
    Lee, JY
    Lee, MW
    Choi, BI
    ACADEMIC RADIOLOGY, 2006, 13 (03) : 343 - 352
  • [10] Hepatic bipolar radiofrequency ablation using perfused-cooled electrodes:: a comparative study in the ex vivo bovine liver
    Lee, JM
    Han, JK
    Kim, SH
    Lee, JY
    Choi, SH
    Choi, BI
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (923): : 944 - 949