Multipolar radiofrequency ablation with internally cooled electrodes:: Experimental study in ex vivo bovine liver with mathernatic modeling

被引:64
|
作者
Clasen, S
Schmidt, D
Boss, A
Dietz, K
Kröber, SM
Claussen, CD
Pereira, PL
机构
[1] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Med Biometry, Tubingen, Germany
[3] Univ Tubingen, Inst Pathol, D-7400 Tubingen, Germany
关键词
D O I
10.1148/radiol.2382050571
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the size and geometry of thermally induced coagulation by Using multipolar radiofrequency (RF) ablation and to determine a mathematic model to predict coagulation volume. Materials and Methods: Multipolar RF ablations (n = 80) were pet-formed in ex vivo bovine livers by using three internally cooled bipolar same shaft. Applicators were placed in a trianglilar array (spacing, 2-5 cm) and were activated in multipolar mode (power output, 75-225 W). The size and geometry of the coagulation zone, together with ablation time, were assessed. Mathematic functions were fitted. and the goodness or fit was assessed by using r(2). Results: Coagulation volome, short-axis diameter, and ablation time were dependent on power output an([ applicator distance. The maximum zone of coagulation (volume, 324 cm(3); short-axis diameter. 8.4 cm: ablation time, 193 min) was induced with a power output or 75 W at an applicator distance of 5 cm. Coagulation volume and ablation time decreased as power output increased. Power outputs Of 100-125 W at applicator distances of 2-4 cm led to a reasonable compromise between coagulation volume and ablation time. At 2 cm (100 W), coagulation volume, 3 short-axis diameter, and ablation time were 66 cm, 4.5 cm, and 19 min, respectively; at 3 cm (100 W), go cm(3),13 5.2 3 cm, and 22 min, respectively; at 4 cm (100 W) 132 cm 6.1 cm, and 27 min, respectively; at 2 cm (125 W), 56 cm 3 4.2 cm. and 9 min, respectively: at 3 cot (125 W), 73 cm 4.9 cm, and 12 min. respectively; and at. 4 cm (125 W) 103 cm(3), 5.5 cm, and 16 min, respectively. At applicator distances of 4 ern (>125 W) and 5 cm (>100 W), the zones of coagulation were not confluent. Coagulation on volume (r(2) = 0.80) and RF ablation time (r(2) = 0.93) were determined by using the mathematic model. Conclusions: Multipolar RF ablation with three bipolar applicators may produce large volumes of confluent coagulation ex vivo. A compromise is necessary between prolonged RF ablations at lower power outputs, which produce larger volumes of coagulation. and faster RF ablations at higher power outputs, which produce smaller volumes of coagulation. (c) RSNA, 2006.
引用
下载
收藏
页码:881 / 890
页数:10
相关论文
共 50 条
  • [1] Multipolar radiofrequency ablation using internally cooled electrodes in ex vivo bovine liver: Correlation between volume of coagulation and amount of applied energy
    Clasen, Stephan
    Rempp, Hansjoerg
    Schmidt, Diethard
    Schraml, Christina
    Hoffmann, Ruediger
    Claussen, Claus D.
    Pereira, Philippe L.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (01) : 111 - 113
  • [2] Radiofrequency Ablation Zones in Ex Vivo Bovine and In Vivo Porcine Livers: Comparison of the Use of Internally Cooled Electrodes and Internally Cooled Wet Electrodes
    Cha, Jihoon
    Choi, Dongil
    Lee, Min Woo
    Rhim, Hyunchul
    Kim, Young-sun
    Lim, Hyo K.
    Yoon, Jung Hwan
    Park, Cheol Keun
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (06) : 1235 - 1240
  • [3] Radiofrequency Ablation Zones in Ex Vivo Bovine and In Vivo Porcine Livers: Comparison of the Use of Internally Cooled Electrodes and Internally Cooled Wet Electrodes
    Jihoon Cha
    Dongil Choi
    Min Woo Lee
    Hyunchul Rhim
    Young-sun Kim
    Hyo K. Lim
    Jung Hwan Yoon
    Cheol Keun Park
    CardioVascular and Interventional Radiology, 2009, 32 : 1235 - 1240
  • [4] Comparison of ablation performance between dual internally cooled wet tip and conventional dual internally cooled tip radiofrequency electrodes: an experimental study in ex vivo bovine liver
    Cha, Dong Ik
    Lee, Min Woo
    Jeong, Woo Kyoung
    Ha, Sang Yun
    Ahn, Soo Hyun
    Rhim, Hyunchul
    Lim, Hyo Keun
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (01) : 332 - 340
  • [5] Radiofrequency Ablation with an Internally Cooled Monopolar Directional Electrode: Ex Vivo and in Vivo Experimental Studies in the Liver
    Yu, Mi Hye
    Lee, Jae Young
    Jun, Su Ryoung
    Kim, Kyung Won
    Kim, Se Hyung
    Han, Joon Koo
    Choi, Byung Ihn
    RADIOLOGY, 2016, 278 (02) : 395 - 404
  • [6] Bipolar Radiofrequency ablation using internally cooled electrodes in ex vivo bovine liver -: Prediction of coagulation volume from applied energy
    Clasen, Stephan
    Schmidt, Diethard
    Dietz, Klaus
    Boss, Andreas
    Kroeber, Stefan M.
    Schraml, Christina
    Fritz, Jan
    Claussen, Claus D.
    Pereira, Philippe L.
    INVESTIGATIVE RADIOLOGY, 2007, 42 (01) : 29 - 36
  • [7] Increasing radiofrequency ablation volumes with the use of internally cooled electrodes and injected hydrochloric acid in ex vivo bovine livers
    Jiang, Xiong-Ying
    Zhang, Tian-Qi
    Li, Guo
    Gu, Yang-Kui
    Gao, Fei
    Yao, Wang
    Zhang, Yan-yang
    Huang, Jin-hua
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 35 (01) : 37 - 43
  • [8] Large-volume radiofrequency ablation of ex vivo bovine liver with multiple cooled cluster electrodes
    Haemmerich, D
    Lee, FT
    Schutt, DJ
    Sampson, LA
    Webster, JG
    Fine, JP
    Mahvi, DM
    RADIOLOGY, 2005, 234 (02) : 563 - 568
  • [9] Hepatic bipolar radiofrequency ablation using perfused-cooled electrodes:: a comparative study in the ex vivo bovine liver
    Lee, JM
    Han, JK
    Kim, SH
    Lee, JY
    Choi, SH
    Choi, BI
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (923): : 944 - 949
  • [10] An ex-vivo experimental study on optimization of bipolar radiofrequency liver ablation using perfusion-cooled electrodes
    Lee, JM
    Han, JK
    Kim, SH
    Lee, JY
    Shin, KS
    Choi, BI
    ACTA RADIOLOGICA, 2005, 46 (05) : 443 - 451