A broadband two axis flux-gate magnetometer

被引:0
|
作者
Palangio, P [1 ]
机构
[1] Ist Nazl Geofis, I-00143 Rome, Italy
来源
ANNALI DI GEOFISICA | 1998年 / 41卷 / 03期
关键词
flux-gate magnetometer;
D O I
暂无
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
A broadband two axis flux-sate magnetometer was developed to obtain high sensitivity in magnetotelluric measurements. In magnetotelluric sounding, natural low frequency electromagnetic fields are used to estimate the conductivity of the Earth's interior. Because variations in the natural magnetic field have small amplitude (10-100 pT) in the frequency range 1 Hz to 100 Hz, highly sensitive magnetic sensors are required. In magnetotelluric measurements two long and heavy solenoids, which must be installed, in the field station, perpendicular to each other (north-south and east-west) and levelled in the horizontal plane are used. The coil is a critical component in magnetotelluric measurements because very slight motions create noise voltages, particularly troublesome in wooded areas; generally the installation takes place in a shallow trench. Moreover the coil records the derivative of the variations rather than the magnetic field variations, consequently the transfer function (amplitude and phase) of this sensor is not constant throughout the frequency range 0.001-100 Hz. The instrument, developed at L'Aquila Geomagnetic Observatory, has a flat response in both amplitude and phase in the frequency band DC-100 Hz, in addition it has low weight, low power, small volume and it is easier to install in the field than induction magnetometers. The sensivity of this magnetometer is 10 pT rms.
引用
收藏
页码:499 / 509
页数:11
相关论文
共 50 条
  • [1] A 3 COMPONENT FLUX-GATE MAGNETOMETER
    LIU, SJ
    LU, J
    GAO, LZ
    SU, XY
    ZHOU, CB
    ACTA GEOPHYSICA SINICA, 1980, 23 (03): : 298 - 305
  • [2] NEW TYPE OF FLUX-GATE MAGNETOMETER
    GEYGER, WA
    JOURNAL OF APPLIED PHYSICS, 1962, 33 (03) : 1280 - &
  • [3] Flux-gate Magnetometer for Mars Exploration
    Zhao, Hua
    Zhu, G. W.
    Yu, P.
    Wang, J. D.
    Yu, M. F.
    Li, L.
    SEVENTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND CONTROL TECHNOLOGY: OPTOELECTRONIC TECHNOLOGY AND INSTUMENTS, CONTROL THEORY AND AUTOMATION, AND SPACE EXPLORATION, 2008, 7129
  • [4] Construction of 3-Axis Flux-gate Magnetometer for Attitude Control of Satellite
    Son, Derac
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2006, 16 (03): : 182 - 185
  • [5] Digital flux-gate magnetometer structural analysis
    Korepanov, V
    Berkman, R
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (08) : 734 - 737
  • [6] Design of flux-gate magnetometer with tiny probe
    Wei, Z
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 576 - 577
  • [7] Flux-gate magnetometer spin axis offset calibration using the electron drift instrument
    Plaschke, Ferdinand
    Nakamura, Rumi
    Leinweber, Hannes K.
    Chutter, Mark
    Vaith, Hans
    Baumjohann, Wolfgang
    Steller, Manfred
    Magnes, Werner
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (10)
  • [8] Construction of 3-axis Flux-gate Magnetometer That Measure Total Magnetic Field
    Son, Derac
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2019, 29 (05): : 171 - 176
  • [9] FLUX-GATE MAGNETOMETER MEASUREMENTS OF CONTINUING CURRENTS IN LIGHTNING
    WILLIAMS, DP
    BROOK, M
    JOURNAL OF GEOPHYSICAL RESEARCH, 1962, 67 (04): : 1662 - +