A broadband two axis flux-gate magnetometer

被引:0
|
作者
Palangio, P [1 ]
机构
[1] Ist Nazl Geofis, I-00143 Rome, Italy
来源
ANNALI DI GEOFISICA | 1998年 / 41卷 / 03期
关键词
flux-gate magnetometer;
D O I
暂无
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
A broadband two axis flux-sate magnetometer was developed to obtain high sensitivity in magnetotelluric measurements. In magnetotelluric sounding, natural low frequency electromagnetic fields are used to estimate the conductivity of the Earth's interior. Because variations in the natural magnetic field have small amplitude (10-100 pT) in the frequency range 1 Hz to 100 Hz, highly sensitive magnetic sensors are required. In magnetotelluric measurements two long and heavy solenoids, which must be installed, in the field station, perpendicular to each other (north-south and east-west) and levelled in the horizontal plane are used. The coil is a critical component in magnetotelluric measurements because very slight motions create noise voltages, particularly troublesome in wooded areas; generally the installation takes place in a shallow trench. Moreover the coil records the derivative of the variations rather than the magnetic field variations, consequently the transfer function (amplitude and phase) of this sensor is not constant throughout the frequency range 0.001-100 Hz. The instrument, developed at L'Aquila Geomagnetic Observatory, has a flat response in both amplitude and phase in the frequency band DC-100 Hz, in addition it has low weight, low power, small volume and it is easier to install in the field than induction magnetometers. The sensivity of this magnetometer is 10 pT rms.
引用
收藏
页码:499 / 509
页数:11
相关论文
共 50 条
  • [21] Development of a High Sensitivity Giant Magneto-Impedance Magnetometer: Comparison With a Commercial Flux-Gate
    Dufay, B.
    Saez, S.
    Dolabdjian, C.
    Yelon, A.
    Menard, D.
    IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (01) : 85 - 88
  • [22] Flux-gate like 2D magnetometer based on a single magnetic tunnel junction
    Malinowski, G
    Hehn, M
    Kammerer, JB
    Sajieddine, M
    Jouguelet, E
    Hébrard, L
    Alnot, P
    Braun, F
    Schuhl, A
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2005, 30 (02): : 113 - 116
  • [23] Flux-Gate Magnetometers Design Peculiarities
    Valery Korepanov
    Andriy Marusenkov
    Surveys in Geophysics, 2012, 33 : 1059 - 1079
  • [24] Flux-Gate Magnetometers Design Peculiarities
    Korepanov, Valery
    Marusenkov, Andriy
    SURVEYS IN GEOPHYSICS, 2012, 33 (05) : 1059 - 1079
  • [25] DIGITAL DETECTION OF THE FLUX-GATE SENSOR OUTPUT SIGNAL
    PRIMDAHL, F
    HERNANDO, B
    PETERSEN, JR
    NIELSEN, OV
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1994, 5 (04) : 359 - 362
  • [27] FLUX-GATE SENSOR-BASED ON PLANAR TECHNOLOGY
    VINCUERIA, I
    TUDANCA, M
    AROCA, C
    LOPEZ, E
    SANCHEZ, MC
    SANCHEZ, P
    IEEE TRANSACTIONS ON MAGNETICS, 1994, 30 (06) : 5042 - 5045
  • [28] Metrological Properties of Flux-Gate Sensors and Magnetometers.
    Tumanski, Slawomir
    Rozprawy Elektrotechniczne, 1986, 32 (03): : 813 - 834
  • [29] Calibration of flux-gate magnetometers using relative motion
    Auster, HU
    Fornacon, KH
    Georgescu, E
    Glassmeier, KH
    Motschmann, U
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (07) : 1124 - 1131
  • [30] Interinstrument calibration using magnetic field data from the flux-gate magnetometer (FGM) and electron drift instrument (EDI) onboard Cluster
    Nakamura, R.
    Plaschke, F.
    Teubenbacher, R.
    Giner, L.
    Baumjohann, W.
    Magnes, W.
    Steller, M.
    Torbert, R. B.
    Vaith, H.
    Chutter, M.
    Fornacon, K. -H.
    Glassmeier, K. -H.
    Carr, C.
    GEOSCIENTIFIC INSTRUMENTATION METHODS AND DATA SYSTEMS, 2014, 3 (01) : 1 - 11