Flux-gate magnetometer spin axis offset calibration using the electron drift instrument

被引:11
|
作者
Plaschke, Ferdinand [1 ]
Nakamura, Rumi [1 ]
Leinweber, Hannes K. [2 ]
Chutter, Mark [3 ]
Vaith, Hans [3 ]
Baumjohann, Wolfgang [1 ]
Steller, Manfred [1 ]
Magnes, Werner [1 ]
机构
[1] Austrian Acad Sci, Space Res Inst, A-8010 Graz, Austria
[2] Univ Calif Los Angeles, Dept Earth & Space Sci, Los Angeles, CA 90024 USA
[3] Univ New Hampshire, Durham, NH 03824 USA
基金
奥地利科学基金会;
关键词
flux-gate magnetometer; electron drift instrument; in-flight calibration; spin axis offset; IN-FLIGHT DETERMINATION; SPACECRAFT;
D O I
10.1088/0957-0233/25/10/105008
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Spin-stabilization of spacecraft immensely supports the in-flight calibration of on-board flux-gate magnetometers (FGMs). From 12 calibration parameters in total, 8 can be easily obtained by spectral analysis. From the remaining 4, the spin axis offset is known to be particularly variable. It is usually determined by analysis of Alfvenic fluctuations that are embedded in the solar wind. In the absence of solar wind observations, the spin axis offset may be obtained by comparison of FGM and electron drift instrument (EDI) measurements. The aim of our study is to develop methods that are readily usable for routine FGM spin axis offset calibration with EDI. This paper represents a major step forward in this direction. We improve an existing method to determine FGM spin axis offsets from EDI time-of-flight measurements by providing it with a comprehensive error analysis. In addition, we introduce a new, complementary method that uses EDI beam direction data instead of time-of-flight data. Using Cluster data, we show that both methods yield similarly accurate results, which are comparable yet more stable than those from a commonly used solar wind-based method.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] In-flight calibration of the spin axis offset of a fluxgate magnetometer with an electron drift instrument
    Leinweber, H. K.
    Russell, C. T.
    Torkar, K.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (10)
  • [2] Interinstrument calibration using magnetic field data from the flux-gate magnetometer (FGM) and electron drift instrument (EDI) onboard Cluster
    Nakamura, R.
    Plaschke, F.
    Teubenbacher, R.
    Giner, L.
    Baumjohann, W.
    Magnes, W.
    Steller, M.
    Torbert, R. B.
    Vaith, H.
    Chutter, M.
    Fornacon, K. -H.
    Glassmeier, K. -H.
    Carr, C.
    GEOSCIENTIFIC INSTRUMENTATION METHODS AND DATA SYSTEMS, 2014, 3 (01) : 1 - 11
  • [3] A broadband two axis flux-gate magnetometer
    Palangio, P
    ANNALI DI GEOFISICA, 1998, 41 (03): : 499 - 509
  • [4] A 3 COMPONENT FLUX-GATE MAGNETOMETER
    LIU, SJ
    LU, J
    GAO, LZ
    SU, XY
    ZHOU, CB
    ACTA GEOPHYSICA SINICA, 1980, 23 (03): : 298 - 305
  • [5] NEW TYPE OF FLUX-GATE MAGNETOMETER
    GEYGER, WA
    JOURNAL OF APPLIED PHYSICS, 1962, 33 (03) : 1280 - &
  • [6] Flux-gate Magnetometer for Mars Exploration
    Zhao, Hua
    Zhu, G. W.
    Yu, P.
    Wang, J. D.
    Yu, M. F.
    Li, L.
    SEVENTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND CONTROL TECHNOLOGY: OPTOELECTRONIC TECHNOLOGY AND INSTUMENTS, CONTROL THEORY AND AUTOMATION, AND SPACE EXPLORATION, 2008, 7129
  • [8] Construction of 3-Axis Flux-gate Magnetometer for Attitude Control of Satellite
    Son, Derac
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2006, 16 (03): : 182 - 185
  • [9] Digital flux-gate magnetometer structural analysis
    Korepanov, V
    Berkman, R
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (08) : 734 - 737
  • [10] Design of flux-gate magnetometer with tiny probe
    Wei, Z
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 576 - 577