Simplified patient-specific renal dosimetry in 177Lu therapy: a proof of concept

被引:7
|
作者
Ligonnet, Thomas [1 ,2 ]
Pistone, Daniele [3 ,4 ]
Auditore, Lucrezia [5 ]
Italiano, Antonio [3 ,4 ]
Amato, Ernesto [4 ,5 ]
Campenni, Alfredo [5 ,6 ]
Schaefer, Niklaus [2 ,7 ]
Boughdad, Sarah [2 ,7 ]
Baldari, Sergio [5 ,6 ]
Gnesin, Silvano [1 ,2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Univ Lausanne, Lausanne, Switzerland
[3] Univ Messina, MIFT Dept, Messina, Italy
[4] Ist Nazl Fis Nucl, Sez Catania, Catania, Italy
[5] Univ Messina, BIOMORF Dept, Messina, Italy
[6] Univ Hosp G Martino, Nucl Med Unit, Messina, Italy
[7] Lausanne Univ Hosp, Dept Nucl Med & Mol Imaging, Lausanne, Switzerland
关键词
Internal dosimetry; Monte Carlo; PRRT; Kidney; Lu-177; RECEPTOR RADIONUCLIDE THERAPY; NEUROENDOCRINE TUMORS; INDIVIDUALIZED DOSIMETRY; INTERNAL DOSIMETRY; KIDNEY; LU-177-DOTATATE; RADIOTHERAPY; TISSUE; IMPACT;
D O I
10.1016/j.ejmp.2021.11.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this proof-of-concept study is to propose a simplified personalized kidney dosimetry procedure in Lu-177 peptide receptor radionuclide therapy (PRRT) for neuroendocrine tumors and metastatic prostate cancer. It relies on a single quantitative SPECT/CT acquisition and multiple radiometric measurements executed with a collimated external probe, properly directed on kidneys. Methods: We conducted a phantom study involving external count-rate measurements in an abdominal phantom setup filled with activity concentrations of (99)mTc, reproducing patient-relevant organ effective half-lives occurring in Lu-177 PRRT. GATE Monte Carlo (MC) simulations of the experiment, using (99)mTc and Lu-177 as sources, were performed. Furthermore, we tested this method via MC on a clinical case of Lu-177-DOTATATE PRRT with SPECT/CT images at three time points (2, 20 and 70 hrs), comparing a simplified kidney dosimetry, employing a single SPECT/CT and probe measurements at three time points, with the complete MC dosimetry. Results: The experimentally estimated kidney half-life with background subtraction applied was compatible within 3% with the expected value. The MC simulations of the phantom study, both with (99)mTc and Lu-177, confirmed a similar level of accuracy. Concerning the clinical case, the simplified dosimetric method led to a kidney dose estimation compatible with the complete MC dosimetry within 6%, 12% and 2%, using respectively the SPECT/CT at 2, 20 and 70 hrs. Conclusions: The proposed simplified procedure provided a satisfactory accuracy and would reduce the imaging required to derive the kidney absorbed dose to a unique quantitative SPECT/CT, with consequent benefits in terms of clinic workflows and patient comfort.
引用
收藏
页码:75 / 85
页数:11
相关论文
共 50 条
  • [41] Preclinical comparison of [177Lu]Lu-rhPSMA-10.1 and [177Lu]Lu-rhPSMA-10.2 for endoradiotherapy of prostate cancer: biodistribution and dosimetry studies
    Alexander Wurzer
    Francesco De Rose
    Sebastian Fischer
    Markus Schwaiger
    Wolfgang Weber
    Stephan Nekolla
    Hans-Jürgen Wester
    Matthias Eiber
    Calogero D’Alessandria
    EJNMMI Radiopharmacy and Chemistry, 9
  • [42] Preclinical comparison of [177Lu]Lu-rhPSMA-10.1 and [177Lu]Lu-rhPSMA-10.2 for endoradiotherapy of prostate cancer: biodistribution and dosimetry studies
    Wurzer, Alexander
    De Rose, Francesco
    Fischer, Sebastian
    Schwaiger, Markus
    Weber, Wolfgang
    Nekolla, Stephan
    Wester, Hans-Juergen
    Eiber, Matthias
    D'Alessandria, Calogero
    EJNMMI RADIOPHARMACY AND CHEMISTRY, 2024, 9 (01)
  • [43] Clinical dosimetry in [177Lu]Lu-PSMA therapy: fewer imaging time points, still useful
    De Vries-Huizing, D.
    Rijkhorst, E.
    Owers, E.
    De Wit-Van der Veen, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S126 - S126
  • [44] Renal Dosimetry in [177Lu]Lu-DOTA-TATE Therapy Based on Multiple Small VOIs as an Alternative to Whole-Kidney Segmentation
    Curkic, S.
    Gustafsson, J.
    Jessen, L.
    Ljungberg, M.
    Sundlov, A.
    Gleisner, K. Sjogreen
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S639 - S639
  • [45] Evaluation safety, dosimetry and efficacy of [177Lu]Lu-P15-073 for therapy of bone metastases
    Zhao, Ruiyue
    Lv, Jie
    Xu, Siran
    Jin, WenBin
    Alexoff, David
    Ploessl, Karl
    Zhu, Lin
    Kung, Hank
    Wang, Xinlu
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [46] Current Practice in Reporting Internal Dosimetry for [177Lu]Lu-DOTA-TATE Therapy: Literature Review
    Ivashchenko, O.
    O'Doherty, J.
    Perez, T.
    Tran-Gia, J.
    Hippelainen, E.
    Sandstrom, M.
    Stokke, C.
    Glatting, G.
    Cremonesi, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S368 - S368
  • [47] 131I and 177Lu Voxel Dosimetry: characterization, verification and preliminary patient results
    Richetta, E.
    Valero, C.
    Elia, B.
    Pirro, V.
    Manfredi, M.
    Pellerito, R.
    Stasi, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S743 - S743
  • [48] Towards fully automatized [177Lu]Lu-PSMA personalized dosimetry based on 360° CZT whole-body SPECT/CT: a proof-of-concept
    Dieudonne, Arnaud
    Terro, Aya
    Dumouchel, Arthur
    Perret, Solene
    Edet-Sanson, Agathe
    Vera, Pierre
    Hapdey, Sebastien
    Modzelewski, Romain
    Tonnelet, David
    Decazes, Pierre
    EJNMMI PHYSICS, 2025, 12 (01):
  • [49] Production logistics of 177Lu for radionuclide therapy
    Pillai, MRA
    Chakraborty, S
    Das, T
    Venkatesh, M
    Ramamoorthy, N
    APPLIED RADIATION AND ISOTOPES, 2003, 59 (2-3) : 109 - 118
  • [50] Patient-specific dosimetry adapted to variable number of SPECT/CT time-points per cycle for 177Lu-DOTATATE therapy
    Vergnaud, Laure
    Giraudet, Anne-Laure
    Moreau, Aurelie
    Salvadori, Julien
    Imperiale, Alessio
    Baudier, Thomas
    Badel, Jean-Noel
    Sarrut, David
    EJNMMI PHYSICS, 2022, 9 (01):