Simplified patient-specific renal dosimetry in 177Lu therapy: a proof of concept

被引:7
|
作者
Ligonnet, Thomas [1 ,2 ]
Pistone, Daniele [3 ,4 ]
Auditore, Lucrezia [5 ]
Italiano, Antonio [3 ,4 ]
Amato, Ernesto [4 ,5 ]
Campenni, Alfredo [5 ,6 ]
Schaefer, Niklaus [2 ,7 ]
Boughdad, Sarah [2 ,7 ]
Baldari, Sergio [5 ,6 ]
Gnesin, Silvano [1 ,2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Univ Lausanne, Lausanne, Switzerland
[3] Univ Messina, MIFT Dept, Messina, Italy
[4] Ist Nazl Fis Nucl, Sez Catania, Catania, Italy
[5] Univ Messina, BIOMORF Dept, Messina, Italy
[6] Univ Hosp G Martino, Nucl Med Unit, Messina, Italy
[7] Lausanne Univ Hosp, Dept Nucl Med & Mol Imaging, Lausanne, Switzerland
关键词
Internal dosimetry; Monte Carlo; PRRT; Kidney; Lu-177; RECEPTOR RADIONUCLIDE THERAPY; NEUROENDOCRINE TUMORS; INDIVIDUALIZED DOSIMETRY; INTERNAL DOSIMETRY; KIDNEY; LU-177-DOTATATE; RADIOTHERAPY; TISSUE; IMPACT;
D O I
10.1016/j.ejmp.2021.11.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this proof-of-concept study is to propose a simplified personalized kidney dosimetry procedure in Lu-177 peptide receptor radionuclide therapy (PRRT) for neuroendocrine tumors and metastatic prostate cancer. It relies on a single quantitative SPECT/CT acquisition and multiple radiometric measurements executed with a collimated external probe, properly directed on kidneys. Methods: We conducted a phantom study involving external count-rate measurements in an abdominal phantom setup filled with activity concentrations of (99)mTc, reproducing patient-relevant organ effective half-lives occurring in Lu-177 PRRT. GATE Monte Carlo (MC) simulations of the experiment, using (99)mTc and Lu-177 as sources, were performed. Furthermore, we tested this method via MC on a clinical case of Lu-177-DOTATATE PRRT with SPECT/CT images at three time points (2, 20 and 70 hrs), comparing a simplified kidney dosimetry, employing a single SPECT/CT and probe measurements at three time points, with the complete MC dosimetry. Results: The experimentally estimated kidney half-life with background subtraction applied was compatible within 3% with the expected value. The MC simulations of the phantom study, both with (99)mTc and Lu-177, confirmed a similar level of accuracy. Concerning the clinical case, the simplified dosimetric method led to a kidney dose estimation compatible with the complete MC dosimetry within 6%, 12% and 2%, using respectively the SPECT/CT at 2, 20 and 70 hrs. Conclusions: The proposed simplified procedure provided a satisfactory accuracy and would reduce the imaging required to derive the kidney absorbed dose to a unique quantitative SPECT/CT, with consequent benefits in terms of clinic workflows and patient comfort.
引用
收藏
页码:75 / 85
页数:11
相关论文
共 50 条
  • [21] Practical kidney dosimetry in peptide receptor radionuclide therapy using [177Lu]Lu-DOTATOC and [177Lu]Lu-DOTATATE with focus on uncertainty estimates
    Peter Frøhlich Staanum
    Anders Floor Frellsen
    Marie Louise Olesen
    Peter Iversen
    Anne Kirstine Arveschoug
    EJNMMI Physics, 8
  • [22] Patient-specific microdosimetry: a proof of concept
    DeCunha, Joseph M.
    Villegas, Fernanda
    Vallieres, Martin
    Torres, Jose
    Camilleri-Broet, Sophie
    Enger, Shirin A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18):
  • [23] The technologist role in 177Lu dosimetry for PRRT (Peptide Receptor Radionuclide Therapy)
    Leoni, E.
    Filice, A.
    Palmieri, A.
    Ghiraldini, G.
    Fioroni, F.
    Grassi, E.
    Cola, S.
    Versari, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S850 - S851
  • [24] Patient-Specific Dosimetry in Radioligand Therapy (RLT) for Metastatic Prostate Cancer Using 177Lu-DKFZ-PSMA-617
    Mahmoudi, Elahe
    Pirayesh, Elahe
    Deevband, Mohammad Reza
    Amoui, Mahasti
    Rad, Mehrdad Ghorbani
    Ghorbani, Mahdi
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 55 (05) : 237 - 244
  • [25] Influence of sampling schedules on [177Lu]Lu-PSMA dosimetry
    Andreas Rinscheid
    Peter Kletting
    Matthias Eiber
    Ambros J. Beer
    Gerhard Glatting
    EJNMMI Physics, 7
  • [26] Influence of sampling schedules on [177Lu]Lu-PSMA dosimetry
    Rinscheid, Andreas
    Kletting, Peter
    Eiber, Matthias
    Beer, Ambros J.
    Glatting, Gerhard
    EJNMMI PHYSICS, 2020, 7 (01)
  • [27] Patient-Specific Dosimetry in Radioligand Therapy (RLT) for Metastatic Prostate Cancer Using 177Lu-DKFZ-PSMA-617
    Elahe Mahmoudi
    Elahe Pirayesh
    Mohammad Reza Deevband
    Mahasti Amoui
    Mehrdad Ghorbani Rad
    Mahdi Ghorbani
    Nuclear Medicine and Molecular Imaging, 2021, 55 : 237 - 244
  • [28] Uncertainty propagation for SPECT/CT-based renal dosimetry in 177Lu peptide receptor radionuclide therapy
    Gustafsson, Johan
    Brolin, Gustav
    Cox, Maurice
    Ljungberg, Michael
    Johansson, Lena
    Gleisner, Katarina Sjogreen
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21): : 8329 - 8346
  • [29] Quantifying Renal And Tumor Doses with Individualized Dosimetry In 177Lu DOTATATE Therapy - What Difference Does It Make?
    Wong, R.
    Laidley, D.
    Myrehaug, S. D.
    Brierley, J.
    Juergens, R.
    Yeung, I. W. T.
    Breen, S.
    Driscoll, B.
    Shessel, A.
    Farncombe, T.
    Zukotynski, K.
    Stodilka, R.
    Caldwell, C. B.
    Liu, Z.
    Valliant, J.
    McCann, J.
    Metser, U.
    Mohan, R.
    Beauregard, J. M.
    Jaffray, D. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : S205 - S205
  • [30] Preparation of Patient Doses of [177Lu]Lu-DOTATATE and [177Lu]Lu-PSMA-617 with Carrier Added (CA) and No Carrier Added (NCA) 177Lu
    Nanabala, Raviteja
    Pillai, Maroor Raghavan Ambikalmajan
    Gopal, Buvaneswari
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 56 (06) : 313 - 322