Simplified patient-specific renal dosimetry in 177Lu therapy: a proof of concept

被引:7
|
作者
Ligonnet, Thomas [1 ,2 ]
Pistone, Daniele [3 ,4 ]
Auditore, Lucrezia [5 ]
Italiano, Antonio [3 ,4 ]
Amato, Ernesto [4 ,5 ]
Campenni, Alfredo [5 ,6 ]
Schaefer, Niklaus [2 ,7 ]
Boughdad, Sarah [2 ,7 ]
Baldari, Sergio [5 ,6 ]
Gnesin, Silvano [1 ,2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Univ Lausanne, Lausanne, Switzerland
[3] Univ Messina, MIFT Dept, Messina, Italy
[4] Ist Nazl Fis Nucl, Sez Catania, Catania, Italy
[5] Univ Messina, BIOMORF Dept, Messina, Italy
[6] Univ Hosp G Martino, Nucl Med Unit, Messina, Italy
[7] Lausanne Univ Hosp, Dept Nucl Med & Mol Imaging, Lausanne, Switzerland
关键词
Internal dosimetry; Monte Carlo; PRRT; Kidney; Lu-177; RECEPTOR RADIONUCLIDE THERAPY; NEUROENDOCRINE TUMORS; INDIVIDUALIZED DOSIMETRY; INTERNAL DOSIMETRY; KIDNEY; LU-177-DOTATATE; RADIOTHERAPY; TISSUE; IMPACT;
D O I
10.1016/j.ejmp.2021.11.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this proof-of-concept study is to propose a simplified personalized kidney dosimetry procedure in Lu-177 peptide receptor radionuclide therapy (PRRT) for neuroendocrine tumors and metastatic prostate cancer. It relies on a single quantitative SPECT/CT acquisition and multiple radiometric measurements executed with a collimated external probe, properly directed on kidneys. Methods: We conducted a phantom study involving external count-rate measurements in an abdominal phantom setup filled with activity concentrations of (99)mTc, reproducing patient-relevant organ effective half-lives occurring in Lu-177 PRRT. GATE Monte Carlo (MC) simulations of the experiment, using (99)mTc and Lu-177 as sources, were performed. Furthermore, we tested this method via MC on a clinical case of Lu-177-DOTATATE PRRT with SPECT/CT images at three time points (2, 20 and 70 hrs), comparing a simplified kidney dosimetry, employing a single SPECT/CT and probe measurements at three time points, with the complete MC dosimetry. Results: The experimentally estimated kidney half-life with background subtraction applied was compatible within 3% with the expected value. The MC simulations of the phantom study, both with (99)mTc and Lu-177, confirmed a similar level of accuracy. Concerning the clinical case, the simplified dosimetric method led to a kidney dose estimation compatible with the complete MC dosimetry within 6%, 12% and 2%, using respectively the SPECT/CT at 2, 20 and 70 hrs. Conclusions: The proposed simplified procedure provided a satisfactory accuracy and would reduce the imaging required to derive the kidney absorbed dose to a unique quantitative SPECT/CT, with consequent benefits in terms of clinic workflows and patient comfort.
引用
收藏
页码:75 / 85
页数:11
相关论文
共 50 条
  • [1] Patient-specific compartmental models for [177Lu]LuPSMA-617 therapy
    Li, W.
    Kupitz, D.
    Spielmann, V.
    Kamp, A.
    Katzdobler, L.
    Giussani, A.
    Kreissl, M.
    Grosser, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S799 - S800
  • [2] Modelling of a Patient-Specific 177Lu-Dotatate Therapy Renal Dosimetry Process for Investigation of Uncertainties
    Gustafsson, J.
    Brolin, G.
    Cox, M.
    Ljungberg, M.
    Johansson, L.
    Gleisner, K. Sjogreen
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S158 - S158
  • [3] Accuracy of two dosimetry software programs for 177Lu radiopharmaceutical therapy using voxel-based patient-specific phantoms
    Ramonaheng, Keamogetswe
    van Staden, Johannes A.
    du Raan, Hanlie
    HELIYON, 2022, 8 (07)
  • [4] PROVIDING ADVICE TO 177Lu THERAPY PATIENTS UPON DISCHARGE-A PATIENT-SPECIFIC METHOD
    O'mahoney, Eoin
    INTERNAL MEDICINE JOURNAL, 2023, 53 : 29 - 30
  • [5] Feasibility of simplifying renal dosimetry in 177Lu peptide receptor radionuclide therapy
    Sundlov, Anna
    Gustafsson, Johan
    Brolin, Gustav
    Mortensen, Nadja
    Hermann, Rebecca
    Bernhardt, Peter
    Svensson, Johanna
    Ljungberg, Michael
    Tennvall, Jan
    Gleisner, Katarina Sjogreen
    EJNMMI PHYSICS, 2018, 5
  • [6] Feasibility of simplifying renal dosimetry in 177Lu peptide receptor radionuclide therapy
    Anna Sundlöv
    Johan Gustafsson
    Gustav Brolin
    Nadja Mortensen
    Rebecca Hermann
    Peter Bernhardt
    Johanna Svensson
    Michael Ljungberg
    Jan Tennvall
    Katarina Sjögreen Gleisner
    EJNMMI Physics, 5
  • [7] Patient level dosimetry for radionuclide therapy: proof of concept for patients receiving 177Lu-DOTATATE
    St James, Sara
    Padilla-Morales, Erika
    Bergsland, Emily
    Hope, Thomas
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [8] Patient-Specific Dosimetry of 177Lu-DOTATATE Peptide Receptor Radionuclide Therapy with High Activities
    Beykan, S.
    Eberlein, U.
    Werner, R. A.
    Lapa, C.
    Buck, A. K.
    Kudlich, T.
    Lassmann, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S33 - S33
  • [9] Results of individual patient dosimetry in peptide receptor radionuclide therapy with 177Lu DOTA-TATE and 177Lu DOTA-NOC
    Wehrmann, Christiane
    Senftleben, Stefan
    Zachert, Carolin
    Mueller, Dirk
    Baum, Richard P.
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2007, 22 (03) : 406 - 416
  • [10] Patient-specific pharmacokinetics and dosimetry over multiple therapy cycles during 177Lu-based radionuclide therapy: a study for 177Lu-DOTATATE and 177Lu-PSMA
    Gosewisch, A.
    Ermoschkin, L.
    Ilhan, H.
    Todica, A.
    Vamacka, L.
    Bartenstein, P.
    Boening, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S270 - S271