Isolation of HIV-1 RNA from plasma: Evaluation of eight different extraction methods

被引:41
|
作者
Verhofstede, C
Fransen, K
Marissens, D
Verhelst, R
vanderGroen, G
Lauwers, S
Zissis, G
Plum, J
机构
[1] INST TROP GENEESKUNDE,MICROBIOL LAB,ANTWERP,BELGIUM
[2] FREE UNIV BRUSSELS,ZIEKENHUIS ST PIETER,VIROL LAB,B-1050 BRUSSELS,BELGIUM
[3] FREE UNIV BRUSSELS,ZIEKENHUIS JETTE,MICROBIOL LAB,B-1050 BRUSSELS,BELGIUM
关键词
RNA extraction; HIV-1; RNA quantification; RT-PCR;
D O I
10.1016/0166-0934(96)02062-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The efficacy of eight different methods for the extraction of HIV-1 RNA from plasma was compared. The RNA preparation method that gave the best results by RT-PCR was the one described by Chomczynski and Sacchi (1987, Anal. Biochem. 162, 156-159). This method consists of a guanidine thiocyanate treatment followed by three phenol-chloroform-isoamylalcohol extractions and an ethanol precipitation. The disadvantage of this method is that it is time consuming and less suitable for the extraction of large series of samples. Moreover, due to the large number of procedural steps, there is a greater risk of sample mix-up or contamination. Of the single-step RNA purification methods, good results were obtained with the TRIzol method (Gibco Life Technologies, Paisley, UK) and with the extraction method offered by the NASBA kit (Organon Teknika, Turnhout, Belgium). The above single-step methods are recommended since both are sensitive enough to detect low copy numbers of HIV-RNA in the plasma of asymptomatic patients, and require only 2 h for completion. For most of the methods evaluated the inter-test variablity was acceptable (mean variation coefficient between duplicate extraction varied between 17.3 and 47.3%). Inter-laboratory reproducibility was evaluated only for the TRIzol-method and found to be low (mean variation coefficient 63.4).
引用
收藏
页码:155 / 159
页数:5
相关论文
共 50 条
  • [21] Importance of RNA isolation methods for analysis of exosomal RNA: Evaluation of different methods
    Eldh, Maria
    Lotvall, Jan
    Malmhall, Carina
    Ekstrom, Karin
    MOLECULAR IMMUNOLOGY, 2012, 50 (04) : 278 - 286
  • [22] Intraocular and plasma HIV-1 RNA loads and HIV uveitis
    Pathanapitoon, Kessara
    Riemens, Anjo
    Kongyai, Natedao
    Sirirungsi, Wasna
    Leechanachai, Pranee
    Ausayakhun, Somsanguan
    Ayuso, Viera Kalinina
    Kunavisarut, Paradee
    de Groot-Mijnes, Jolanda D. F.
    Rothova, Aniki
    AIDS, 2011, 25 (01) : 81 - 86
  • [23] HIV-1 RNA in plasma and genital tract secretions in women infected with HIV-1
    Kovacs, A
    Chan, LS
    Chen, ZC
    Meyer, WA
    Muderspach, L
    Young, M
    Anastos, K
    Levine, AM
    JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 1999, 22 (02): : 124 - 131
  • [24] Detection of HIV-1 RNA in seminal plasma samples from treated patients with undetectable HIV-1 RNA in blood plasma on a 2002-2011 survey
    Lambert-Niclot, Sidonie
    Tubiana, Roland
    Beaudoux, Celine
    Lefebvre, Gilles
    Caby, Fabienne
    Bonmarchand, Manuela
    Naouri, Michele
    Schubert, Benoit
    Dommergues, Marc
    Calvez, Vincent
    Flandre, Philippe
    Poirot, Catherine
    Marcelin, Anne-Genevieve
    AIDS, 2012, 26 (08) : 971 - 975
  • [25] Comparative evaluation of Aptima HIV-1 Qualitative RNA assay performance using plasma and serum specimens from persons with established HIV-1 infection
    Ethridge, Steven F.
    Wesolowski, Laura G.
    Nasrullah, Muazzam
    Kennedy, M. Susan
    Delaney, Kevin P.
    Candal, Debra
    Owen, S. Michele
    JOURNAL OF CLINICAL VIROLOGY, 2011, 52 : S63 - S66
  • [26] Multicenter evaluation of the NucliSens EasyQ HIV-1 v1.1 assay for the quantitative detection of HIV-1 RNA in plasma
    de Mendoza, C
    Koppelman, M
    Montès, B
    Ferre, V
    Soriano, V
    Cuypers, H
    Segondy, M
    Oosterlaken, T
    JOURNAL OF VIROLOGICAL METHODS, 2005, 127 (01) : 54 - 59
  • [27] Quantification of HIV-1 RNA in plasma: Comparable results with the NASBA HIV-1 RNA QT and the AMPLICOR HIV monitor test
    Vandamme, AM
    Schmit, JC
    VanDooren, S
    VanLaethem, K
    Gobbers, E
    Kok, W
    Goubau, P
    Witvrouw, M
    Peetermans, W
    DeClercq, E
    Desmyter, J
    JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 1996, 13 (02) : 127 - 139
  • [28] Plasma RNA quantification and HIV-1 divergent strains
    Plantier, JC
    Gueudin, M
    Damond, T
    Braun, J
    Mauclère, P
    Simon, F
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2003, 33 (01) : 1 - 7
  • [29] Estimating the Impact of Plasma HIV-1 RNA Reductions on Heterosexual HIV-1 Transmission Risk
    Lingappa, Jairam R.
    Hughes, James P.
    Wang, Richard S.
    Baeten, Jared M.
    Celum, Connie
    Gray, Glenda E.
    Stevens, Wendy S.
    Donnell, Deborah
    Campbell, Mary S.
    Farquhar, Carey
    Essex, M.
    Mullins, James I.
    Coombs, Robert W.
    Rees, Helen
    Corey, Lawrence
    Wald, Anna
    PLOS ONE, 2010, 5 (09): : 1 - 7
  • [30] Hepatitis B vaccination and plasma HIV-1 RNA
    Cheeseman, SH
    Davaro, RE
    Ellison, RT
    NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (19): : 1272 - 1272