Quantification of HIV-1 RNA in plasma: Comparable results with the NASBA HIV-1 RNA QT and the AMPLICOR HIV monitor test

被引:88
|
作者
Vandamme, AM
Schmit, JC
VanDooren, S
VanLaethem, K
Gobbers, E
Kok, W
Goubau, P
Witvrouw, M
Peetermans, W
DeClercq, E
Desmyter, J
机构
[1] ORGANON TEKN, BOXTEL, NETHERLANDS
[2] UNIV HOSP, DEPT INTERNAL MED, LOUVAIN, BELGIUM
[3] KATHOLIEKE UNIV LEUVEN, UNIV HOSP, B-3000 LOUVAIN, BELGIUM
来源
关键词
HIV-1; RNA-PCR; NASBA; amplicor; viral load;
D O I
10.1097/00042560-199610010-00003
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
We investigated and compared the reproducibility, accuracy, detection limits, and dynamic ranges of two commercial kits for quantification of RNA viral load using a titrated virus stock (laboratory strain HIV-1 IIIB) and 107 plasma samples of 25 HIV-1-infected patients. The high reproducibility of both methods (SD = 0.2-0.3 log for both methods) allowed reliable detection of a 0.5 log change in RNA viral load. Both methods had a similar detection limit (at least 10(3) RNA copies/ml plasma) and a dynamic range that extended over a 5 log (AMPLICOR) or a 6 log (NASBA) range of HIV-1 input. For HIV-1 IIIB, the viral load was compatible with measurements of virus-associated p24 antigen. For 21 patients (91 samples), the RNA viral load was similar with both methods, differing by no more than 0.5 log. For four patients, the difference in viral load between the two methods was >0.5 log for all 16 samples. For three of these patients, this could be explained by mismatches with primers or probes in the gag sequence; there was no correlation to the viral subtype. The RNA viral load determination was highly sensitive compared with p24 antigen measurement (>95% of patients had a detectable viral load vs. 40% who had a detectable p24 level), but in the p24-positive samples the correlation between the antigen level and the RNA viral load was of only borderline significance. We also found that the viral RNA in whole blood was stable for at least 48 h during transport at room temperature. These observations show that both the NASBA HIV-1 RNA QT test and the AMPLICOR HIV monitor test are reliable parameters of the viral load, with great promise for their use as potential surrogate markers.
引用
收藏
页码:127 / 139
页数:13
相关论文
共 50 条
  • [1] Longitudinal study of plasma HIV-1 RNA concentrations during the asymptomatic stage of HIV infection measured using AMPLICOR HIV monitor and NASBA HIV-1 RNA QT tests
    Delamare, C
    Burgard, M
    Deveau, C
    Chaix, ML
    Ivanoff, S
    Ramirez, D
    Tachet, A
    Bary, M
    Rouzioux, C
    [J]. JOURNAL OF MEDICAL VIROLOGY, 1998, 54 (01) : 60 - 68
  • [2] Amplicor HIV monitor, NASBA HIV-1 RNA QT and quantiplex HIV RNA version 2.0 viral load assays: a Canadian evaluation
    Prud'homme, IT
    Kim, JE
    Pilon, RG
    Minkus, T
    Hawley-Foss, N
    Cameron, W
    Rud, EW
    [J]. JOURNAL OF CLINICAL VIROLOGY, 1998, 11 (03) : 189 - 202
  • [3] Comparative evaluation of NASBA HIV-1 RNA QT, AMPLICOR-HIV monitor, and QUANTIPLEX HIV RNA assay, three methods for quantification of human immunodeficiency virus type I RNA in plasma
    Revets, H
    Marissens, D
    DeWit, S
    Lacor, P
    Clumeck, N
    Lauwers, S
    Zissis, G
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (05) : 1058 - 1064
  • [4] Comparative evaluation of the Cobas Amplicor HIV-1 Monitor™ ultrasensitive test, the new Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor™ ultrasensitive test and the versant HIV RNA 3.0 assays for quantitation of HIV-1 RNA in plasma samples
    Berger, A
    Scherzed, L
    Sturmer, M
    Preiser, W
    Doerr, HW
    Rabenau, HF
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2005, 33 (01) : 43 - 51
  • [5] QUANTIFICATION OF HIV-1 RNA IN PLASMA USING NASBA (TM) DURING HIV-1 PRIMARY INFECTION
    VANGEMEN, B
    KIEVITS, T
    SCHUKKINK, R
    VANSTRIJP, D
    MALEK, LT
    SOOKNANAN, R
    HUISMAN, HG
    LENS, P
    [J]. JOURNAL OF VIROLOGICAL METHODS, 1993, 43 (02) : 177 - 188
  • [6] QUANTIFICATION OF HIV-1 RNA IN PLASMA USING THE NASBA(R) AMPLIFICATION SYSTEM COMPARED TO AN IN-HOUSE QUANTITATIVE RNA-PCR AND THE AMPLICOR(R) HIV MONITOR TEST
    VANDAMME, AM
    SCHMIT, JC
    VANDOOREN, S
    VANLAETHEM, K
    GOBBERS, E
    KOK, W
    ALBRECHT, N
    HUYGEN, R
    DESMYTER, J
    DECLERCQ, E
    [J]. JOURNAL OF CELLULAR BIOCHEMISTRY, 1995, : 213 - 213
  • [7] Comparison of three HIV1 RNA quantitation assays: NASBA HIV1 RNA QT, amplicor HIV monitor and quantiplex HIV RNA assay
    Revets, H
    Marrissens, D
    Dewit, S
    Clumeck, N
    Lauwers, S
    [J]. BIOLOGICALS, 1996, 24 (03) : 222 - 222
  • [8] Evaluation of a competitive quantitative RT-PCR-ELISA system for quantification of HIV-1 RNA in plasma: comparison with COBAS Amplicor HIV-1 monitor test
    Jamehdar, S. Amel
    Sabahi, F.
    Forouzandeh, M.
    Abdolbaghi, M. Haji
    Kazemnejad, A.
    Mahboudi, F.
    Edalat, R.
    Ravanshad, M.
    [J]. INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S320 - S320
  • [9] HIV-1 subtypes and plasma RNA quantification
    Damond, F
    Apetrei, C
    Descamps, D
    Brun-Vézinet, F
    Simon, F
    [J]. AIDS, 1999, 13 (02) : 286 - 288
  • [10] DETECTION OF HIV-1 RNA IN PLASMA BY ISOTHERMAL AMPLIFICATION (NASBA) IRRESPECTIVE OF THE STAGE OF HIV-1 INFECTION
    ZAAIJER, HL
    KOK, W
    TENVEEN, JH
    REESINK, HW
    FOOLEN, H
    WINKEL, IN
    HUISMAN, JG
    CUYPERS, HTM
    KIEVITS, T
    LELIE, PN
    [J]. JOURNAL OF VIROLOGICAL METHODS, 1995, 52 (1-2) : 175 - 181