Submillimeter-wavelength plasma chemical diagnostics for semiconductor manufacturing

被引:5
|
作者
Benck, EC
Golubiatnikov, GY
Fraser, GT
Ji, B
Motika, SA
Karwacki, EJ
机构
[1] Natl Inst Stand & Technol, Phys Lab, Opt Technol Div, Gaithersburg, MD 20899 USA
[2] Air Prod & Chem Inc, Allentown, PA 18195 USA
来源
关键词
D O I
10.1116/1.1605431
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Submillimeter-wavelength linear-absorption spectroscopy has been applied to the chemical diagnostics of reactive-ion etching plasmas in a modified capacitively coupled gaseous electronics conference reactor. Approximately I mW of narrow-band (< 10 kHz) submillimeter radiation between 450 and 750 GHz is produced using a backward-wave oscillator (BWO). The BWO is frequency stabilized to a harmonic of a 78-118 GHz frequency synthesizer. The submillimeter method offers high sensitivity for the approximate to I MHz linewidth, Doppler-broadened absorption lines typical of gas-phase molecules at a total pressure of less than 133 Pa (1 Tort). A large number of molecules can be detected, limited primarily by the need for a permanent electric dipole moment and for accurate line frequency predictions, the latter of which are often available in the literature. The capabilities of the diagnostic method have been demonstrated by the following three applications: (1) the measurement of water-vapor contamination in the reactor and in the precursor gas by monitoring a rotational transition of H2O in the reactor just prior to the initiation of the plasma; (2) the assessment of progress in the cleaning of the reactor by an O-2/Ar plasma after a fluorocarbon plasma etch by monitoring the build up of the concentration Of O-3 and the depletion of the concentration of CF2O in the plasma; and (3) the determination of the endpoint in the etching of a SiO2 thin film on silicon by an octafluorocyclobutane/O-2/Ar plasma by monitoring the decrease in the concentration of SiO in the plasma. The last observation is made possible by the large electric dipole moment for SiO of 1 X 10(-29) C in (3.1 D), which gives a low minimum detectable number density for the radical of 2 X 10(7) cm(-3) for an optical pathlength of 39 cm. (C) 2003 American Vacuum Society.
引用
收藏
页码:2067 / 2075
页数:9
相关论文
共 50 条
  • [32] PULSED SUBMILLIMETER LASER WITH OPTICAL PUMPING FOR PLASMA DIAGNOSTICS.
    Manita, O.F.
    Instruments and Experimental Techniques (English Translation of Pribory I Tekhnika Eksperimenta), 1979, 22 (2 pt 2): : 552 - 554
  • [33] SUBMILLIMETER COMPENSATION INTERFEROMETER FOR OPTICALLY DENSE-PLASMA DIAGNOSTICS
    KUTOVOI, VD
    PETROV, GD
    SAMARSKII, PA
    TREGUBOV, SI
    MEASUREMENT TECHNIQUES, 1979, 22 (02) : 143 - 145
  • [34] PULSED SUBMILLIMETER LASER FOR OPTICALLY DENSE-PLASMA DIAGNOSTICS
    KUTOVOI, VD
    LESNIKOV, EV
    NIKITIN, NV
    PETROV, GD
    SAMARSKII, PA
    KVANTOVAYA ELEKTRONIKA, 1975, 2 (09): : 2066 - 2067
  • [35] Microstrip stabilized semiconductor quantum well generator for millimeter and submillimeter wavelength range
    Karuzskii, AL
    Dravin, VA
    Ignatyev, AS
    Krapivka, AE
    Mityagin, YA
    Murzin, VN
    Perestoronin, AV
    Tskhovrebov, AM
    MILLIMETER AND SUBMILLIMETER WAVES III, 1996, 2842 : 319 - 327
  • [36] Multi-Domain Data Integration for Plasma Diagnostics in Semiconductor Manufacturing Using Tri-CycleGAN
    Kang, Minji
    Jang, Sung Kyu
    Kim, Jihun
    Kim, Seongho
    Kim, Changmin
    Lee, Hyo-Chang
    Kang, Wooseok
    Choi, Min Sup
    Kim, Hyeongkeun
    Kim, Hyeong-U
    JOURNAL OF SENSOR AND ACTUATOR NETWORKS, 2024, 13 (06)
  • [37] Chemical use in the semiconductor manufacturing industry
    Kim, Sunju
    Yoon, Chungsik
    Ham, Seunghon
    Park, Jihoon
    Kwon, Ohun
    Park, Donguk
    Choi, Sangjun
    Kim, Seungwon
    Ha, Kwonchul
    Kim, Won
    INTERNATIONAL JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2018, 24 (3-4) : 109 - 118
  • [38] CHEMICAL AND RADIATION HAZARDS IN SEMICONDUCTOR MANUFACTURING
    BALDWIN, DG
    STEWART, JH
    SOLID STATE TECHNOLOGY, 1989, 32 (08) : 131 - 135
  • [39] DEVELOPMENT OF A HIGH-INTENSITY PULSED SUBMILLIMETER LASER FOR PLASMA DIAGNOSTICS
    EVANS, DE
    SHARP, LE
    PEEBLES, WA
    TAYLOR, G
    OPTICS COMMUNICATIONS, 1976, 18 (01) : 9 - 10
  • [40] Plasma ion diagnostics using semiconductor detectors
    Hirata, M
    Cho, T
    Sakamoto, Y
    Kohagura, J
    Kanke, S
    Takahashi, K
    Okamura, T
    Nakashima, Y
    Yatsu, K
    Tamano, T
    Kondoh, T
    Miyoshi, S
    ICPP 96 CONTRIBUTED PAPERS - PROCEEDINGS OF THE 1996 INTERNATIONAL CONFERENCE ON PLASMA PHYSICS, VOLS 1 AND 2, 1997, : 1478 - 1481