Submillimeter-wavelength plasma chemical diagnostics for semiconductor manufacturing

被引:5
|
作者
Benck, EC
Golubiatnikov, GY
Fraser, GT
Ji, B
Motika, SA
Karwacki, EJ
机构
[1] Natl Inst Stand & Technol, Phys Lab, Opt Technol Div, Gaithersburg, MD 20899 USA
[2] Air Prod & Chem Inc, Allentown, PA 18195 USA
来源
关键词
D O I
10.1116/1.1605431
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Submillimeter-wavelength linear-absorption spectroscopy has been applied to the chemical diagnostics of reactive-ion etching plasmas in a modified capacitively coupled gaseous electronics conference reactor. Approximately I mW of narrow-band (< 10 kHz) submillimeter radiation between 450 and 750 GHz is produced using a backward-wave oscillator (BWO). The BWO is frequency stabilized to a harmonic of a 78-118 GHz frequency synthesizer. The submillimeter method offers high sensitivity for the approximate to I MHz linewidth, Doppler-broadened absorption lines typical of gas-phase molecules at a total pressure of less than 133 Pa (1 Tort). A large number of molecules can be detected, limited primarily by the need for a permanent electric dipole moment and for accurate line frequency predictions, the latter of which are often available in the literature. The capabilities of the diagnostic method have been demonstrated by the following three applications: (1) the measurement of water-vapor contamination in the reactor and in the precursor gas by monitoring a rotational transition of H2O in the reactor just prior to the initiation of the plasma; (2) the assessment of progress in the cleaning of the reactor by an O-2/Ar plasma after a fluorocarbon plasma etch by monitoring the build up of the concentration Of O-3 and the depletion of the concentration of CF2O in the plasma; and (3) the determination of the endpoint in the etching of a SiO2 thin film on silicon by an octafluorocyclobutane/O-2/Ar plasma by monitoring the decrease in the concentration of SiO in the plasma. The last observation is made possible by the large electric dipole moment for SiO of 1 X 10(-29) C in (3.1 D), which gives a low minimum detectable number density for the radical of 2 X 10(7) cm(-3) for an optical pathlength of 39 cm. (C) 2003 American Vacuum Society.
引用
收藏
页码:2067 / 2075
页数:9
相关论文
共 50 条
  • [11] SUBMILLIMETER-WAVELENGTH HETERODYNE SPECTROSCOPY AND REMOTE-SENSING OF THE UPPER-ATMOSPHERE
    WATERS, JW
    PROCEEDINGS OF THE IEEE, 1992, 80 (11) : 1679 - 1701
  • [12] MILLIMETER-WAVELENGTH AND SUBMILLIMETER-WAVELENGTH SPECTRUM AND MOLECULAR-CONSTANTS OF T2O
    DELUCIA, FC
    HELMINGER, P
    GORDY, W
    PHYSICAL REVIEW A, 1973, 8 (06) : 2785 - 2791
  • [13] SUBMILLIMETER WAVE PLASMA DIAGNOSTICS
    LUHMANN, NC
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1986, 3 (13): : P11 - P11
  • [14] SUBMILLIMETER LASER INTERFEROMETER FOR PLASMA DIAGNOSTICS
    KOLEROV, AN
    PETROV, GD
    RADIOTEKHNIKA I ELEKTRONIKA, 1974, 19 (06): : 1282 - 1286
  • [15] POLARIZED SUBMILLIMETER INTERFEROMETER FOR PLASMA DIAGNOSTICS
    KUTOVOI, VD
    PETROV, GD
    PETRYAKOV, AI
    SAMARSKII, PA
    MEASUREMENT TECHNIQUES, 1976, 19 (08) : 1179 - 1180
  • [16] OBSERVATION OF COHERENT DIFFRACTION RADIATION FROM BUNCHED ELECTRONS PASSING THROUGH A CIRCULAR APERTURE IN THE MILLIMETER-WAVELENGTH AND SUBMILLIMETER-WAVELENGTH REGIONS
    SHIBATA, Y
    HASEBE, S
    ISHI, K
    TAKAHASHI, T
    OHSAKA, T
    IKEZAWA, M
    NAKAZATO, T
    OYAMADA, M
    URASAWA, S
    YAMAKAWA, T
    KONDO, Y
    PHYSICAL REVIEW E, 1995, 52 (06): : 6787 - 6794
  • [17] Semiconductor superlattice frequency multiplier for the submillimeter wavelength range
    Renk, KF
    Ernst, T
    Muthmann, M
    Rogl, A
    Stahl, BI
    Endres, C
    Lewen, F
    Vowinkel, B
    Winnewisser, G
    Koschurinov, YI
    Pavel'ev, DG
    Ustinov, V
    Zhukov, A
    Maleev, N
    Vasilyev, A
    CONFERENCE DIGEST OF THE 2004 JOINT 29TH INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES AND 12TH INTERNATIONAL CONFERENCE ON TERAHERTZ ELECTRONICS, 2004, : 125 - 126
  • [18] FAR-INFRARED AND SUBMILLIMETER-WAVELENGTH OBSERVATIONS OF STAR-FORMING DENSE CORES .1. SPECTRA
    LADD, EF
    ADAMS, FC
    CASEY, S
    DAVIDSON, JA
    FULLER, GA
    HARPER, DA
    MYERS, PC
    PADMAN, R
    ASTROPHYSICAL JOURNAL, 1991, 366 (01): : 203 - 220
  • [19] SUBMILLIMETER WAVEGUIDE LASER INTERFEROMETER FOR PLASMA DIAGNOSTICS
    EPISHIN, VA
    POKORKYAKHO, NG
    SVICH, VA
    TOPKOV, AN
    URINSON, AS
    YUNDEV, DN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1981, 24 (01) : 155 - 157
  • [20] SUBMILLIMETER LASER INTERFEROMETER FOR PLASMA DIAGNOSTICS.
    Berezhnyi, V.L.
    Kononenko, V.I.
    1600, (20):