Effect of Different Signal Processing Techniques on a Calibration Free Pulse Oximeter

被引:0
|
作者
Chugh, Soumil [1 ]
Akula, Aparna [2 ]
机构
[1] Punjab Univ, CCET, Chandigarh, India
[2] CSIR CSIO, Chandigarh, India
关键词
Beer-Lambert Law; Discrete Kalman Filter; Exponential Moving Averaging Filter; Independent Component Analysis; Photoplethysmography; Pulse Oximetry; Pulse Rate; Savitzky-Golay; ABSORPTION-SPECTRA; CARBOXYHEMOGLOBIN; OXYHEMOGLOBIN; ALGORITHMS;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A pulse oximeter is a medical device that measures pulse rate and oxygen saturation levels of a person non-invasively. Monitoring of health parameters of a patient requires a device that gives accurate results in all conditions and is not affected by artifacts arising from environmental and physiological factors. One of the noise factors we focus in this paper is motion artifacts. These artifacts affect the quality of signal acquired by the sensor leading to imperfect results. In this paper, four digital filtering techniques, which include Exponential Moving Averaging, Savitzky-Golay, Independent Component Analysis and Discrete Kalman filter, are implemented to remove artifacts from a noisy photoplethysmographic signal acquired by shining lights in the range of Red and IR wavelengths on the fingertip of a person. Pulse rate is determined in the time domain by detecting peaks of the signal while blood oxygen levels are measured using Beer-Lambert Law via a calibration-free method on the artifact-free PPG signal. The results obtained are then compared with a commercial pulse oximeter available in the market and performance of different filtering techniques on a PPG signal is evaluated.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Nuclear spectroscopy pulse analyser board based on digital signal processing techniques
    Simoes, PCPS
    Martins, JC
    Correia, CMBA
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 460 - 463
  • [32] EFFECT OF ANEMIA ON PULSE OXIMETER ACCURACY AT LOW SATURATION
    SEVERINGHAUS, JW
    KOH, SO
    JOURNAL OF CLINICAL MONITORING, 1990, 6 (02): : 85 - 88
  • [33] A review of the effect of skin pigmentation on pulse oximeter accuracy
    Al-Halawani, Raghda
    Charlton, Peter H.
    Qassem, Meha
    Kyriacou, Panayiotis A.
    PHYSIOLOGICAL MEASUREMENT, 2023, 44 (05)
  • [34] THE EFFECT OF VARYING LED INTENSITY ON PULSE OXIMETER ACCURACY
    DEKOCK, JP
    REYNOLDS, KJ
    TARASSENKO, L
    MOYLE, JTB
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1991, 15 (03) : 111 - 116
  • [35] Digital pulp space infiltration of local anesthetic enhances pulse oximeter signal
    Krovvidi, VHP
    Grover, VK
    Chari, P
    ANESTHESIA AND ANALGESIA, 2000, 91 (03): : 763 - 763
  • [36] Calibration of the Pulse Signal Decay Effect of Full-Waveform Hyperspectral LiDAR
    Zhang, Changsai
    Gao, Shuai
    Niu, Zheng
    Pei, Jie
    Bi, Kaiyi
    Sun, Gang
    SENSORS, 2019, 19 (23)
  • [37] Signal quality and power consumption of a new prototype reflectance pulse oximeter sensor
    Branche, P
    Mendelson, Y
    2005 IEEE 31ST ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2005, : 42 - 43
  • [38] DIGITAL NERVE BLOCKS CAN RESTORE PULSE OXIMETER SIGNAL-DETECTION
    BOURKE, DL
    GRAYSON, RF
    ANESTHESIA AND ANALGESIA, 1991, 73 (06): : 815 - 817
  • [39] Calibration of a reflectance pulse oximeter in fetal lambs for arterial oxygen saturations below 70%
    Carter, AM
    Stiller, R
    Konig, V
    Jorgensen, JS
    Svendsen, P
    Huch, R
    JOURNAL OF THE SOCIETY FOR GYNECOLOGIC INVESTIGATION, 1998, 5 (05) : 255 - 259
  • [40] Calibration of a Reflectance Pulse Oximeter in Fetal Lambs for Arterial Oxygen Saturations Below 70%
    Anthony M. Carter
    Ruth Stiller
    Volker König
    Jan S. Jørgensen
    Per Svendsen
    Renate Huch
    The Journal of the Society for Gynecologic Investigation: JSGI, 1998, 5 (5): : 255 - 259