Effect of Different Signal Processing Techniques on a Calibration Free Pulse Oximeter

被引:0
|
作者
Chugh, Soumil [1 ]
Akula, Aparna [2 ]
机构
[1] Punjab Univ, CCET, Chandigarh, India
[2] CSIR CSIO, Chandigarh, India
关键词
Beer-Lambert Law; Discrete Kalman Filter; Exponential Moving Averaging Filter; Independent Component Analysis; Photoplethysmography; Pulse Oximetry; Pulse Rate; Savitzky-Golay; ABSORPTION-SPECTRA; CARBOXYHEMOGLOBIN; OXYHEMOGLOBIN; ALGORITHMS;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A pulse oximeter is a medical device that measures pulse rate and oxygen saturation levels of a person non-invasively. Monitoring of health parameters of a patient requires a device that gives accurate results in all conditions and is not affected by artifacts arising from environmental and physiological factors. One of the noise factors we focus in this paper is motion artifacts. These artifacts affect the quality of signal acquired by the sensor leading to imperfect results. In this paper, four digital filtering techniques, which include Exponential Moving Averaging, Savitzky-Golay, Independent Component Analysis and Discrete Kalman filter, are implemented to remove artifacts from a noisy photoplethysmographic signal acquired by shining lights in the range of Red and IR wavelengths on the fingertip of a person. Pulse rate is determined in the time domain by detecting peaks of the signal while blood oxygen levels are measured using Beer-Lambert Law via a calibration-free method on the artifact-free PPG signal. The results obtained are then compared with a commercial pulse oximeter available in the market and performance of different filtering techniques on a PPG signal is evaluated.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Study on nuclear pulse signal processing method based on DSP techniques
    Wang, Yong-Gang
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2004, 24 (05):
  • [22] Monitoring radar signal with digital alias-free signal processing techniques
    Liu, XY
    Shang, LP
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 2, 2004, : 617 - 621
  • [23] Processing of pulse oximeter data using discrete wavelet analysis
    Lee, S
    Ibey, BL
    Xu, WJ
    Wilson, MA
    Ericson, MN
    Coté, GL
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (07) : 1350 - 1352
  • [24] Standard-free calibration transfer - An evaluation of different techniques
    Malli, B.
    Birlutiu, A.
    Natschlaeger, T.
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2017, 161 : 49 - 60
  • [25] CALIBRATION TECHNIQUES OF GAS SENSORS AND SENSOR-SPECIFIC SIGNAL-PROCESSING
    POLLAK, H
    BIOSENSORS : APPLICATIONS IN MEDICINE, ENVIRONMENTAL PROTECTION AND PROCESS CONTROL, 1989, 13 : 371 - 375
  • [26] Clutter removal for landmine using different signal processing techniques
    Abujarad, F
    Jöstingmeier, A
    Omar, AS
    PROCEEDINGS OF THE TENTH INTERNATIONAL CONFERENCE ON GROUND PENETRATING RADAR, VOLS 1 AND 2, 2004, : 697 - 700
  • [27] A pulse oximeter system, OxiSense, with embedded signal processing using an ultra-low power ASIC designed for testability
    Das, Devarshi Mrinal
    Gupta, Aman
    Srivastava, Abhishek
    Vidwans, Amogh
    Ahmad, Meraj
    Shelke, Aniruddha
    Kale, Salil
    Ananthapadmanabhan, J.
    Sharma, Dinesh Kumar
    Baghini, Maryam Shojaei
    MICROELECTRONICS JOURNAL, 2018, 72 : 1 - 10
  • [28] BLOOD-FLOW LIMITS AND PULSE OXIMETER SIGNAL-DETECTION
    LAWSON, D
    NORLEY, I
    KORBON, G
    LOEB, R
    ELLIS, J
    ANESTHESIOLOGY, 1987, 67 (04) : 599 - 603
  • [29] IMPLEMENTATION OF DIGITAL SIGNAL-PROCESSING TECHNIQUES IN THE DESIGN OF THERMAL PULSE FLOWMETERS
    AVIRAV, Y
    GUTERMAN, H
    BENYAAKOV, S
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1990, 39 (05) : 761 - 766
  • [30] PULSE SLIMMING IN MAGNETIC RECORDING USING DIGITAL SIGNAL-PROCESSING TECHNIQUES
    DAVEY, PJ
    DONNELLY, T
    MAPPS, DJ
    MICROPROCESSING AND MICROPROGRAMMING, 1993, 37 (1-5): : 73 - 76