Real-time D transesophageal echocardiography for the assessment of secundum atrial septal defects in children Three dimensional transesophageal echocardiography for assessment of atrial septa! defects

被引:0
|
作者
Kosger, Pelin [1 ]
Sulu, Ayse [1 ]
Akin, Tugcem [2 ]
Kiztanir, Hikmet [1 ]
Ucar, Birsen [1 ]
机构
[1] Eskisehir Osmangazi Univ, Fac Med, Dept Pediat Cardiol, Eskisehir, Turkey
[2] Eskisehir State Hosp, Pediat Cardiol Clin, Eskisehir, Turkey
关键词
ASD; Echocardiography; 3D TEE; Percutaneous closure; CONGENITAL HEART-DISEASE; TRANSCATHETER CLOSURE; DEVICE CLOSURE; OCCLUDER DEVICE; FEASIBILITY; EFFICACY; IMPACT;
D O I
10.4328/ACAM.20533
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: The need for more than one cross-section in the imaging of the atrial septum with two-dimensional (2D) echocardiography creates a limitation in determining the morphology of atrial septal defects (ASD) and negatively affects the success of the percutaneous closure procedure. In this study, measurements of ASDs and surrounding rims obtained by 3D transesophageal echocardiography (TEE) were compared with 2D TEE and angiographic balloon sizing measurements. Material and Methods: The study included 24 pediatric patients with the diagnosis of ASD who were scheduled for transcatheter defect closure. All patients underwent catheter-angiography following a detailed 2D TEE examination. Results: The data of 17 patients with optimal 3D TEE images were analyzed offline in the Q-lab. The diameter of the defects and surrounding rims, which were measured with two- and three-dimensional TEE were similar (p> 0.05). There was a strong correlation between the two measurement techniques in terms of defect diameter (r = 0.896, p <0.001). While the diameter of the defect measured by the sizing balloon was greater than that measured by 2D TEE, it was similar to that measured by 3D TEE (p <0.001, p = 0.14, respectively). There was also a strong correlation between the defect diameter measured by 3D TEE and balloon sizing diameter (r = 0.844. p <0.001). Discussion: The "en face" visualization of the atrial septum with 3D TEE provides adequate identification of the defect morphology and adjacent structures. Furthermore, reliable determination of the defect size by 3D imaging may lead to appropriate device selection without the requirement for invasive measurement techniques such as balloon sizing.
引用
收藏
页码:S301 / S305
页数:5
相关论文
共 50 条
  • [1] Real-Time Three-Dimensional Transesophageal Echocardiography Is Useful for Percutaneous Closure of Multiple Secundum Atrial Septal Defects
    Zhang, Chun
    Li, Zhian
    Xu, Jin
    HELLENIC JOURNAL OF CARDIOLOGY, 2014, 55 (06) : 486 - 491
  • [2] Three-dimensional transesophageal echocardiography of the atrial septal defects
    Roldan, Francisco-Javier
    Vargas-Barron, Jesus
    Vazquez-Antona, Clara
    Munoz Castellanos, Luis
    Erdmenger-Orellana, Julio
    Romero-Cardenas, Angel
    Martinez-Rios, Marco-Antonio
    CARDIOVASCULAR ULTRASOUND, 2008, 6 (1)
  • [3] Three-dimensional transesophageal echocardiography of the atrial septal defects
    Francisco-Javier Roldán
    Jesús Vargas-Barrón
    Clara Vázquez-Antona
    Luis Muñoz Castellanos
    Julio Erdmenger-Orellana
    Ángel Romero-Cárdenas
    Marco-Antonio Martínez-Ríos
    Cardiovascular Ultrasound, 6
  • [4] Real-Time Three-Dimensional Transesophageal Echocardiography in Patients with Secundum Atrial Septal Defects: Outcomes following Transcatheter Closure
    Johri, Amer M.
    Witzke, Christian
    Solis, Jorge
    Palacios, Igor F.
    Inglessis, Ignacio
    Picard, Michael H.
    Passeri, Jonathan J.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (04) : 431 - 437
  • [5] Transesophageal Echocardiography Guided Percutaneous Closure of Secundum Atrial Septal Defects
    Lerakis, Stamatios
    Babaliaros, Vasilis C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (06): : 724 - 727
  • [6] Clinical advantage of real-time three dimensional transesophageal echocardiography in transcatheter closure of multiple atrial septal defects
    Taniguchi, M.
    Akagi, T.
    Watanabe, N.
    Kijima, Y.
    Nakagawa, K.
    Toh, N.
    Kusano, K.
    Ito, H.
    Sano, S.
    EUROPEAN HEART JOURNAL, 2011, 32 : 120 - 120
  • [7] Live/Real Time Three-Dimensional Transesophageal Echocardiography in Percutaneous Closure of Atrial Septal Defects
    Bhaya, Maneesha
    Mutluer, Ferit Onur
    Mahan, Edward
    Mahan, Luke
    Hsiung, Ming C.
    Yin, Wei-Hsian
    Wei, Jeng
    Tsai, Shen-Kou
    Zhao, Guang-Yu
    Yin, Wei-Hsian
    Pradhan, Manish
    Beniwal, Rajesh
    Joshi, Deepak
    Nabavizadeh, Fatemeh
    Singh, Amitoj
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (03): : 345 - 353
  • [8] Anatomic correlation of atrial septal defects by three-dimensional transesophageal echocardiography
    Roldan, F. J.
    Vargas-Barron, J.
    Antona, C. Vazquez
    Cardenas, A. Romero
    Castellanos, L. Munoz
    Orellana, J. Erdmenger
    EUROPEAN HEART JOURNAL, 2006, 27 : 796 - 796
  • [9] Diagnosis of a Fenestrated Secundum Atrial Septal Defect Detected by Real-Time Three-Dimensional Transesophageal Echocardiography
    Schisler, Travis
    Subramaniam, Kathirvel
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2017, 31 (03) : 980 - 982
  • [10] Assessment of the Left Atrial Appendage using Real-time Three Dimensional Transesophageal Echocardiography
    Bai Wenjuan
    Chen Zhongxiu
    Wang Hui
    Wei Xin
    Rao Li
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (16) : C227 - C227