Computational analysis of spray type counter flow liquid desiccant dehumidifier

被引:0
|
作者
Ahmed, M. Ijas [1 ]
Vignesh, R. [1 ]
Kumar, L. Gangadhara Kiran [1 ]
机构
[1] NIT Calicut, Dept Mech Engn, Calicut 673601, Kerala, India
关键词
Liquid desiccant; 3D model; Spray type; Counter flow; Mass transfer; PERFORMANCE;
D O I
10.1016/j.matpr.2020.10.888
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The liquid desiccant air conditioning system (LDAC) is considered as the substitute for the conventional air conditioning system mainly because of its energy-saving characteristics. The dehumidifier is one of the most important components in LDAC, therefore, it is chosen as the system for analysis. A 3D computational model of the spray type dehumidifier with counter flow configuration was created and analysed its mass transfer characteristics for two different cases. 2D CFD models studied by various researchers failed to elaborate on the actual flow process. In order to fill this gap 3D model was created and the analysis was conducted to investigate the influence of flow rate of air and desiccant on the mass transfer performance of the dehumidifier. Air and desiccant flow rate have direct influence on the mass transfer performance of the dehumidifier. In this study, the dehumidification performance is evaluated through the simulation by increasing the desiccant flow rate and simultaneously reducing the airflow rate and the results are observed. ANSYS-FLUENT (R) software is used for the current analysis. The increase in desiccant flow rate and decrease in air flow rate tends to improve the change in humidity ratio (specific moisture removal) from 4.2 to 6.3 g/kg of dry air. The temperature variation of solution keeps increasing as the moisture transfer increases. The rise in temperature of the solution is higher than the air during moisture transfer due to exothermic process. Similarly the equilibrium humidity ratio of solution increased due to moisture absorption during dehumidification, which indicates the decrease in solution concentration during dehumidification. The heating of solution and air during dehumidification will affect the moisture transfer rate, which can be avoided by adding a cooling unit to the liquid desiccant system. (c) 2019 Elsevier Ltd. Selection and Peer-review under responsibility of the scientific committee of the International Mechanical Engineering Congress 2019: Materials Science.
引用
收藏
页码:9820 / 9826
页数:7
相关论文
共 50 条
  • [21] Progress in selecting desiccant and dehumidifier for liquid desiccant cooling system
    Li, Xiu-Wei
    Zhang, Xiao-Song
    Cao, Rong-Quan
    Quan, Shuo
    ENERGY AND BUILDINGS, 2012, 49 : 410 - 418
  • [22] GAS-POWERED LIQUID DESICCANT DEHUMIDIFIER
    RIX, J
    NEVRALA, D
    CHAUVET, L
    PROBERT, SD
    APPLIED ENERGY, 1993, 45 (02) : 167 - 180
  • [23] Counter-crossflow indirect evaporative cooling-assisted liquid desiccant dehumidifier: Model development and parameter analysis
    Zhang, Yanling
    Zhang, Hao
    Yang, Hongxing
    Chen, Yi
    Leung, Chun Wah
    APPLIED THERMAL ENGINEERING, 2022, 217
  • [24] Natural induced flow due to concentration gradient in a liquid desiccant air dehumidifier
    Fazilati, Mohammad Ali
    Sedaghat, Ahmad
    Alemrajabi, Ali Akbar
    APPLIED THERMAL ENGINEERING, 2016, 105 : 105 - 117
  • [25] Performance analysis of liquid desiccant dehumidifier system for various packing density
    Sonowal, Juri
    Mahajan, Mahesh
    Muthukumar, P.
    Anandalakshmi, R.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 38
  • [26] Performance numerical analysis on an internally-cooled liquid desiccant dehumidifier
    Chan, X. M.
    Liu, X. H.
    Jiang, Y.
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 607 - 613
  • [27] Theoretical study of the effect of liquid desiccant mass flow rate on the performance of a cross flow parallel-plate liquid desiccant-air dehumidifier
    Mohammad, Abdulrahman Th
    Bin Mat, Sohif
    Sulaiman, M. Y.
    Sopian, K.
    Al-abidi, Abduljalil A.
    HEAT AND MASS TRANSFER, 2013, 49 (11) : 1587 - 1593
  • [28] Analytical Modeling and Performance Study of a Cross Flow Air Dehumidifier Using Liquid Desiccant
    Bassuoni, M. M.
    MATERIALS RESEARCH AND APPLICATIONS, PTS 1-3, 2014, 875-877 : 1205 - 1213
  • [29] Theoretical study of the effect of liquid desiccant mass flow rate on the performance of a cross flow parallel-plate liquid desiccant-air dehumidifier
    Abdulrahman Th. Mohammad
    Sohif Bin Mat
    M. Y. Sulaiman
    K. Sopian
    Abduljalil A. Al-abidi
    Heat and Mass Transfer, 2013, 49 : 1587 - 1593
  • [30] Numerical study on dehumidification performance of a cross-flow liquid desiccant air dehumidifier
    Lu, Jun
    Wang, Meilin
    Li, Yongcai
    Yang, Lulu
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3630 - 3637