Theoretical study of the effect of liquid desiccant mass flow rate on the performance of a cross flow parallel-plate liquid desiccant-air dehumidifier

被引:0
|
作者
Abdulrahman Th. Mohammad
Sohif Bin Mat
M. Y. Sulaiman
K. Sopian
Abduljalil A. Al-abidi
机构
[1] University Kebangsaan Malaysia,Solar Energy Research Institute
[2] Foundation of Technical Education,Department of Mechanical Engineering, Baqubah Technical Institute
来源
Heat and Mass Transfer | 2013年 / 49卷
关键词
Solution Flow Rate; Moisture Removal; Humidity Ratio; Finite Difference Technique; Liquid Desiccant;
D O I
暂无
中图分类号
学科分类号
摘要
A computer simulation using MATLAB is investigated to predict the distribution of air stream parameters (humidity ratio and temperature) as well as desiccant parameters (temperature and concentration) inside the parallel plate absorber. The present absorber consists of fourteen parallel plates with a surface area per unit volume ratio of 80 m2/m3. Calcium chloride as a liquid desiccant flows through the top of the plates to the bottom while the air flows through the gap between the plates making it a cross flow configuration. The model results show the effect of desiccant mass flow rate on the performance of the dehumidifier (moisture removal and dehumidifier effectiveness). Performance comparisons between present cross-flow dehumidifier and another experimental cross-flow dehumidifier in the literature are carried out. The simulation is expected to help in optimizing of a cross flow dehumidifier.
引用
收藏
页码:1587 / 1593
页数:6
相关论文
共 50 条
  • [1] Theoretical study of the effect of liquid desiccant mass flow rate on the performance of a cross flow parallel-plate liquid desiccant-air dehumidifier
    Mohammad, Abdulrahman Th
    Bin Mat, Sohif
    Sulaiman, M. Y.
    Sopian, K.
    Al-abidi, Abduljalil A.
    [J]. HEAT AND MASS TRANSFER, 2013, 49 (11) : 1587 - 1593
  • [2] Analytical Modeling and Performance Study of a Cross Flow Air Dehumidifier Using Liquid Desiccant
    Bassuoni, M. M.
    [J]. MATERIALS RESEARCH AND APPLICATIONS, PTS 1-3, 2014, 875-877 : 1205 - 1213
  • [3] Numerical study on dehumidification performance of a cross-flow liquid desiccant air dehumidifier
    Lu, Jun
    Wang, Meilin
    Li, Yongcai
    Yang, Lulu
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3630 - 3637
  • [4] Heat and mass transfer model of cross flow liquid desiccant air dehumidifier/regenerator
    Liu, X. H.
    Jiang, Y.
    Qu, K. Y.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (02) : 546 - 554
  • [5] Experimental study on mass transfer performances of cross flow dehumidifier using liquid desiccant
    Liu, X. H.
    Zhang, Y.
    Qu, K. Y.
    Jiang, Y.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (15-16) : 2682 - 2692
  • [6] An experimental study on the dehumidification performance of a counter flow liquid desiccant dehumidifier
    Wang, Lingshi
    Xiao, Fu
    Zhang, Xuejun
    Kumar, Ritunesh
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 70 : 289 - 301
  • [7] Experimental investigation on the heat and mass transfer between air and liquid desiccant in a cross-flow dehumidifier
    Gao, W. Z.
    Liu, J. H.
    Cheng, Y. P.
    Zhang, X. L.
    [J]. RENEWABLE ENERGY, 2012, 37 (01) : 117 - 123
  • [8] Numerical simulation and theoretical analysis of heat and mass transfer in a cross flow liquid desiccant air dehumidifier packed with honeycomb paper
    Dai, YJ
    Zhang, HF
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (9-10) : 1343 - 1356
  • [9] Performance analysis of a quasi-counter flow parallel-plate membrane contactor used for liquid desiccant air dehumidification
    Huang, Si-Min
    Yang, Minlin
    Yang, Xiaoxi
    [J]. APPLIED THERMAL ENGINEERING, 2014, 63 (01) : 323 - 332
  • [10] Sizes optimization on cross-flow dehumidifier using liquid desiccant
    Department of Building Science, Tsinghua University, Beijing 100084, China
    [J]. Taiyangneng Xuebao, 2006, 9 (878-884):