Direct quantification of inorganic iodine in seawater by mixed-mode liquid chromatography-electrospray ionization-mass spectrometry

被引:8
|
作者
Hernaiz-Izquierdo, M. [1 ]
Galindo-Iranzo, P. [1 ]
Garcia-Armada, M. P. [2 ]
Saiz-Lopez, A. [1 ]
Gomara, B. [3 ]
Quintanilla-Lopez, J. E. [1 ]
Lebron-Aguilar, R. [1 ]
机构
[1] CSIC, Inst Phys Chem Rocasolano IQFR, Dept Atmospher Chem & Climate, Serrano 119, Madrid 28006, Spain
[2] Escuela Tecn Super Ingn Ind UPM, Dept Ind Chem Engn, Jose Gutierrez Abascal 2, Madrid 28006, Spain
[3] CSIC, Dept Instrumental Anal & Environm Chem, Inst Gen Organ Chem IQOG, Juan Cierva 3, Madrid 28006, Spain
关键词
Iodide; odate; Seawater; Liquid chromatography-electrospray ionization-mass spectrometry; Mixed-mode stationary phase; ION CHROMATOGRAPHY; DISSOLVED IODINE; ORGANO-IODINE; SPECIATION; IODATE; SAMPLES; WATERS; ATLANTIC; SEA; ELECTROPHORESIS;
D O I
10.1016/j.chroma.2018.12.046
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Atmospheric iodine plays a relevant role in climate change. Bearing in mind that most of this iodine comes from the oceans, analytical methods capable of determining iodine in a challenging matrix as seawater are necessary. In this work, the first method capable of direct determination of total inorganic iodine in seawater at subnanomolar level based on mixed-mode liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) without any sample treatment is presented. Analytical characteristics of the developed method were studied in terms of linear range, limits of detection and quantification, precision, trueness, matrix effect, and robustness. The detection limit for iodide was as low as 0.16 nM, injecting 5 mu L of seawater without any sample treatment and the working linear range of four orders of magnitude was wide enough to cover the broad concentration range observed in seawater samples. Average values for repeatability and intermediate precision were 4.1% and 8.1%, respectively. The suitability of the method was demonstrated through its application to the analysis of several types of samples, including seawater samples taken at different locations along the Spanish Mediterranean coast and some domestic iodized salts. According to the results obtained, the method developed is rapid, easy to apply and to be automated, avoids sample treatment and requires only few microliters of sample. Furthermore, it has a low detection limit and allows the quantification of inorganic iodine over a wide concentration range. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 107
页数:9
相关论文
共 50 条
  • [41] Liquid chromatography-electrospray ionization-mass spectrometry/mass spectrometry characterization of depsides and depsidones from the Chilean lichen Parmotrema perlatum
    Castaneta, Grover
    Sepulveda, Beatriz
    Areche, Carlos
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2024, 30 (02) : 125 - 132
  • [42] Quantification of zolmitriptan in plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry
    Zhang, ZJ
    Xu, FG
    Tian, Y
    Li, W
    Mao, GG
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 227 - 233
  • [43] Identification and quantification of microcystins in water by high performance liquid chromatography-electrospray ionization mass spectrometry
    Yu, RP
    Tao, GJ
    Qing, F
    Chen, Y
    Tang, J
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (12) : 1462 - 1464
  • [44] SEPARATION, CHARACTERIZATION, AND QUANTIFICATION OF ATORVASTATIN AND RELATED IMPURITIES BY LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION MASS SPECTROMETRY
    Mornar, A.
    Damic, M.
    Nigovic, B.
    ANALYTICAL LETTERS, 2010, 43 (18) : 2859 - 2871
  • [45] Optimization strategy for liquid chromatography-electrospray ionization mass spectrometry methods
    Moberg, M
    Bylund, D
    Danielsson, R
    Markides, K
    ANALYST, 2000, 125 (11) : 1970 - 1976
  • [46] Chiral electrokinetic chromatography-electrospray ionization-mass spectrometry using a double junction interface
    Hung, Sih-Hua
    Cheng, Wen-Shuo
    Huang, Ju-Li
    Wang, Che-Wei
    Her, Guor-Rong
    ELECTROPHORESIS, 2012, 33 (04) : 546 - 551
  • [47] Analysis of corticosteroids in hair by Liquid chromatography-electrospray ionization mass spectrometry
    Bévalot, F
    Gaillard, Y
    Lhermitte, MA
    Pépin, G
    JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (02): : 227 - 236
  • [48] Effects of Column Length and Particle Diameter on Phospholipid Analysis by Nanoflow Liquid Chromatography-Electrospray Ionization-Mass Spectrometry
    Lee, Ju Yong
    Lim, Sangsoo
    Moon, Myeong Hee
    MASS SPECTROMETRY LETTERS, 2011, 2 (03) : 65 - 68
  • [49] Solid phase extraction and liquid chromatography-electrospray ionization-mass spectrometry for the determination of bencycloquidium bromide in human plasma
    Zhou, Wenjia
    Ding, Li
    Wang, Yongqing
    Sun, Luning
    Huang, Yao
    Hu, Linlin
    Chen, Xiaoping
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (10): : 897 - 901
  • [50] Trace analysis of antibacterial tylosin A, B, C and D in honey by liquid chromatography-electrospray ionization-mass spectrometry
    Nalda, MJN
    Yagüe, JLB
    Gómez, MTM
    Sevilla, JJJ
    del Nozal, JB
    Pascual, MH
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (03) : 405 - 413