A System for the Characterization and Testing of CdZnTe/CdTe Pixel Detectors for X-ray and Gamma-ray Imaging

被引:9
|
作者
Arodzero, Anatoli [1 ]
Barber, William C. [1 ]
Damron, Matthew Q. [1 ]
Hartsough, Neal E. [1 ]
Iwanczyk, Jan S. [1 ]
Malakhov, Nail [2 ]
Nygard, Einar [2 ]
Moraes, Danielle [3 ]
Weilhammer, Peter [3 ]
Jarron, Pierre [3 ]
机构
[1] DxRay Inc, 19355 Business Ctr Dr, Northridge, CA 91324 USA
[2] Interon AS, N-1386 Asker, Norway
[3] CERN, CH-1211 Geneva, Switzerland
关键词
D O I
10.1109/NSSMIC.2006.353782
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed an automated system for the characterization and testing of CdZnTe/CdTe pixel detectors for x-ray and gamma-ray imaging. A set of custom made pogo-pin arrays and corresponding detector holders have been designed for a precise, non-damaging loading and unloading of detectors to a "measurement habitat" within the system. The architecture of the system is flexible, allowing measurements of current, spectral responses and pulse shapes from individual detector pixels. A multi-channel read-out (up to 256 channels) based on CMOS switches make possible the monitoring of leakage-and /or x-ray induced photo-currents sequentially for all individual pixels, for groups of pixels, or for the full detector with different voltage ramping scenario. A measurement of spectral pixel responses can be done with a Single-Photon-Counting ASIC for up to 256 pixels simultaneously, or from individual pixel(s) with discrete read-out electronics. The test system can satisfy many experimental needs including measurements of a detector's: 1) temporal response under x-ray or gamma ray irradiation; 2) photon count rate performance; 3) bulk/contact charge transport properties; 4) guard ring or/and passivation effectiveness, and 5) long term stability. Control and data acquisition can be conducted with a local computer, or via the Internet. The system has been successfully operated for about 2 years. Examples of the results obtained with detectors fabricated from different material vendors are presented.
引用
收藏
页码:3638 / 3642
页数:5
相关论文
共 50 条
  • [41] CdZnTe detectors for gamma-ray Burst ArcSecond Imaging and Spectroscopy (BASIS)
    Stahle, CM
    Palmer, D
    Bartlett, LM
    Parsons, A
    Shi, ZQ
    Lisse, CM
    Sappington, C
    Cao, N
    Shu, P
    Gehrels, N
    Teegarden, B
    Birsa, F
    Singh, S
    Odom, J
    Hanchak, C
    Tueller, J
    Barthelmy, S
    Krizmanic, J
    Barbier, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 486 - 489
  • [42] CdTe and CdZnTe detectors behavior in X-ray computed tomography conditions
    Ricq, S
    Glasser, F
    Garcin, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3): : 45 - 52
  • [43] PHOTOCONDUCTOR-X GAMMA-RAY DETECTORS AND X-RAY BOLOMETERS
    WANG, CL
    ECKELS, JD
    MORGAN, WV
    POCHA, MD
    SLAUGHTER, DR
    DAVIS, BA
    KANIA, DR
    WAGNER, RS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (08): : 2182 - 2183
  • [44] Characterization of CdZnTe and CdTe:Cl materials and their relationship to X- and gamma-ray detector performance
    Verger, L
    Baffert, N
    Rosaz, M
    Rustique, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 121 - 126
  • [45] Development of CZT Detectors for X-ray and Gamma-ray Astronomy
    Lee, Kuen
    Martin, J. W.
    Garson, A. B., III
    Guo, Q.
    Matteson, J.
    Groza, M.
    Beilicke, M.
    Burger, A.
    de Geronimo, G.
    Krawczynski, H.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XIII, 2011, 8142
  • [46] THALLIUM BROMIDE SEMICONDUCTOR X-RAY AND GAMMA-RAY DETECTORS
    OLSCHNER, F
    SHAH, KS
    LUND, JC
    ZHANG, J
    DALEY, K
    MEDRICK, S
    SQUILLANTE, MR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03): : 504 - 508
  • [47] A counting CdTe pixel detector for hard X-ray and γ-ray imaging
    Fischer, P
    Kouda, M
    Krüger, H
    Lindner, M
    Sato, G
    Takahashi, T
    Watanabe, S
    Wermes, N
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) : 2401 - 2404
  • [48] A pixel design for X-ray imaging with CdTe sensors
    Lambropoulos, C. P.
    Zervakis, E. G.
    Loukas, D.
    PHYSICA STATUS SOLIDI C - CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 5, NO 12 2008, 2008, 5 (12): : 3862 - +
  • [49] CdZnTe pixel array detectors and implications for producing large volume gamma-ray spectrometers
    Brunett, BA
    Van Scyoc, JM
    James, RB
    Schlesinger, TE
    JOURNAL OF APPLIED PHYSICS, 1999, 86 (07) : 3926 - 3933
  • [50] X ray and gamma ray spectroscopy with segmented CdZnTe detectors
    Shor, A
    Eisen, Y
    Mardor, I
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS, 1999, 3769 : 59 - 70