CdTe and CdZnTe detectors behavior in X-ray computed tomography conditions

被引:7
|
作者
Ricq, S [1 ]
Glasser, F [1 ]
Garcin, M [1 ]
机构
[1] CEAG, Dept Syst, LETI, CEA Technol Avancees, F-38054 Grenoble 9, France
关键词
X-ray computed tomography; CdTe/CdZnTe detectors; intense irradiation; trapping/de-trapping; space charge; injection;
D O I
10.1016/S0168-9002(99)01198-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The application of CdTe and CdZnTe 2D array detectors for medical X-ray Computed Tomography (XCT) is investigated. Different metallic electrodes have been deposited on High-Pressure Bridgman Method CdZnTe and on Traveling Heater Method CdTe:Cl. These detectors are exposed to X-rays in the CT irradiation conditions and are characterized experimentally in current mode. Detectors performances such as sensitivity and response speed are studied. They are correlated with charge trapping and de-trapping. The trapped carrier space charges may influence the injection from the electrodes. This enables one to get information on the nature of the predominant levels involved. The performances achieved are encouraging: dynamic ranges higher than 4 decades and current decreases of 3 decades in 4 ms after X-ray beam cut-off are obtained. Nevertheless, these detectors are still limited by high trap densities responsible for the memory effect that makes them unsuitable for XCT. (C) 2000 Elsevier Science B.V. Ail rights reserved.
引用
收藏
页码:45 / 52
页数:8
相关论文
共 50 条
  • [1] Study of CdTe and CdZnTe detectors for X-ray computed tomography
    Ricq, S
    Glasser, F
    Garcin, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 534 - 543
  • [2] THE APPLICATION OF X-RAY CDTE DETECTORS IN THE MEDICAL COMPUTED-TOMOGRAPHY
    ARKADEVA, EN
    ZELENINA, NK
    KARPENKO, VP
    MASLOVA, LV
    MATVEEV, OA
    TERENTEV, AI
    TOMASOV, AA
    YAZYKOV, NN
    [J]. ZHURNAL TEKHNICHESKOI FIZIKI, 1985, 55 (05): : 897 - 901
  • [3] CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems
    Eisen, Y
    Shor, A
    Mardor, I
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 1191 - 1198
  • [4] CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems
    Eisen, Y
    Shor, A
    Mardor, I
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3311 - 3319
  • [5] CdZnTe:Cl crystals for X-ray computer tomography detectors
    Matveev, OA
    Terentev, AI
    Karpenko, VP
    Zelenina, NK
    Fauler, A
    Fiederle, M
    Benz, KW
    [J]. PHYSICA STATUS SOLIDI B-BASIC RESEARCH, 2002, 229 (02): : 1073 - 1076
  • [6] CdTe and CdZnTe materials for room-temperature X-ray and gamma ray detectors
    Eisen, Y
    Shor, A
    [J]. JOURNAL OF CRYSTAL GROWTH, 1998, 184 : 1302 - 1312
  • [7] INVESTIGATION OF CDTE DETECTORS DESIGNED FOR COMPUTER X-RAY TOMOGRAPHY
    KARPENKO, VP
    MATVEEV, OA
    [J]. SEMICONDUCTORS, 1993, 27 (11-12) : 1048 - 1050
  • [8] CdTe and CdZnTe room-temperature X-ray and gamma ray detectors and imaging systems
    Eisen, Y
    Shor, A
    [J]. SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 : 129 - 145
  • [9] Dynamics of native oxide growth on CdTe and CdZnTe X-ray and gamma-ray detectors
    Zazvorka, Jakub
    Franc, Jan
    Beran, Lukas
    Moravec, Pavel
    Pekarek, Jakub
    Veis, Martin
    [J]. SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2016, 17 (01) : 792 - 798
  • [10] New developments in CdTe and CdZnTe detectors for X and γ-ray applications
    L. Verger
    J. P. Bonnefoy
    F. Glasser
    P. Ouvrier-Buffet
    [J]. Journal of Electronic Materials, 1997, 26 : 738 - 744