Ultrasound imaging of quadriceps muscle in patients with knee osteoarthritis: The test-retest and inter-rater reliability and concurrent validity of echo intensity measurement

被引:8
|
作者
Karapinar, Merve [1 ]
Ayyildiz, Veysel Atilla [2 ]
Unal, Meric [3 ]
Firat, Tuzun [4 ]
机构
[1] Suleyman Demirel Univ, Dept Physiotherapy & Rehabil, Fac Hlth Sci, TR-3200 Isparta, Turkey
[2] Suleyman Demirel Univ, Dept Radiol, Fac Med, Isparta, Turkey
[3] Suleyman Demirel Univ, Sports Med Dept, Fac Med, Isparta, Turkey
[4] Hacettepe Univ, Fac Phys Therapy & Rehabil, Ankara, Turkey
关键词
Ultrasound imaging; Reliability; Echo intensity; Knee osteoarthritis; FEMORIS MUSCLE; ADIPOSE-TISSUE; QUALITY; ULTRASONOGRAPHY; AGREEMENT; QUANTITY; YOUNG;
D O I
10.1016/j.msksp.2021.102453
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Echo intensity(EI) on ultrasonography images of skeletal muscle reflects muscle composition. Objectives: The primary aim of the study was to investigate the inter-rater and test-retest reliability of EI using grayscale histogram analysis of the cross-sectional area of quadriceps femoris(QF) muscle in patients with knee osteoarthritis(KOA). The secondary aim of the study was to determine the concurrent validity of the Free Hand Tool(FHT) when compared to Rectangular Marquee Tool(RMT) for calculating the region of interest(ROI) in ImageJ. Methods: This study included thirty patients with KOA. Echogenicity of the QF muscle were performed by two different raters. The reliability analysis was applied using intraclass correlation coefficient(ICC), standard error of measurement(SEM) and coefficient of variation(CV). Spearman rank correlation coefficients were calculated for assessing concurrent validity of the FHT to RMT. The Bland-Altman plots was used to show disagreement between tools. Wilcoxon signed-rank test was used for differences in assessments between test/retest sessions, raters, tools. Results: The inter-rater and test-retest reliability of the EI using FHT and RMT was found to be excellent (ICCFHT = 0.91-0.95, 0.98-0.99, ICCRMT = 0.91-0.98, 0.91-0.99,respectively). Bland-Altman analysis demonstrated a slight bias when region ROI calculations were collected from RMT or FHT (bias ranging from 2.75 to 2.40 a. u). There were no significant differences between test/retest sessions, raters and tools(p > 0.05). Spearman correlation coefficient showed excellent correlation between tools used for echogenicity assessment of QF muscle(p < 0.001). Conclusion: EI assessment using ultrasonography in the QF muscle showed excellent reliability. Evaluating muscle echogenicity using both FHT and RMT appears to be reliable and validity for monitoring muscle changes due to KOA.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG) Test in Patients with Parkinson's Disease
    van Lummel, Rob C.
    Walgaard, Stefan
    Hobert, Markus A.
    Maetzler, Walter
    van Dieen, Jaap H.
    Galindo-Garre, Francisca
    Terwee, Caroline B.
    PLOS ONE, 2016, 11 (03):
  • [42] Norwegian version of the Edinburgh cognitive and behavioural ALS screen: Construct validity, internal consistency, inter-rater, and test-retest reliability
    Taule, Tina
    Eide, Irmelin Smith
    Fjaer, Line
    Myrberget, Mari-Anne
    Oseland, Marit Sofie
    Rensa, Marit Arnevik
    Revheim, Tone
    Tysnes, Ole-Bjorn
    Assmus, Jorg
    Rekand, Tiina
    PLOS ONE, 2023, 18 (05):
  • [43] Diagnostic Interview for Genetic Studies ( DIGS): validity, inter-rater and test-retest reliability of the Thai version (Th-DIGS)
    Sitdhiraksa, Nantawat
    Singhakant, Supachoke
    Rattaapha, Woraphat
    Saisavoey, Nattha
    Chantakarn, Sunanta
    ASEAN JOURNAL OF PSYCHIATRY, 2008, 9 (02): : 104 - 113
  • [44] Intra- And Inter-rater Reliability Of Panoramic Ultrasound Muscle Image Quantification Of The Quadriceps Femoris
    Cleary, Christopher John, Jr.
    Nabavizadeh, Omid
    Young, Kaycie
    Herda, Ashley A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2021, 53 (08): : 108 - 108
  • [45] Inter-rater and test-retest reliability of the seated multidirectional reach test in wheelchair basketball players: A clinical field test
    Bogado, Diego J.
    Boscarol, Kevin A.
    Blajman, Jesica E.
    E-BALONMANO COM, 2025, 21 (01): : 65 - 76
  • [46] Test-retest and inter-rater reliability for the Comprehensive Developmental Inventory for Infants and Toddlers diagnostic and screening tests
    Liao, HF
    Pan, YL
    EARLY HUMAN DEVELOPMENT, 2005, 81 (11) : 927 - 937
  • [47] Test-retest reliability of the L-Test in patients with advanced knee osteoarthritis
    Nalbant, Abdurrahman
    Unver, Bayram
    Karatosun, Vasfi
    PHYSIOTHERAPY THEORY AND PRACTICE, 2022, 38 (13) : 2983 - 2987
  • [48] Excellent test-retest and inter-rater reliability for Tardieu Scale measurements with inertial sensors in elbow flexors of stroke patients
    Paulis, Winifred D.
    Horemans, Herwin L. D.
    Brouwer, Betty S.
    Stam, Henk J.
    GAIT & POSTURE, 2011, 33 (02) : 185 - 189
  • [49] Drug-Induced Extrapyramidal Symptoms Scale of the Norwegian version: inter-rater and test-retest reliability
    Weidle, Bernhard
    Chaulagain, Ashmita
    Stensen, Kenneth
    Aleksic, Branko
    Skokauskas, Norbert
    Inada, Toshiya
    NORDIC JOURNAL OF PSYCHIATRY, 2019, 73 (08) : 546 - 550
  • [50] Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
    Sin, Minki
    Kim, Won-Seok
    Cho, Kyujin
    Paik, Nam-Jong
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (148):