Performance of an AI based CAD system in solid lung nodule detection on chest phantom radiographs compared to radiology residents and fellow radiologists

被引:11
|
作者
Peters, Alan A. [1 ]
Decasper, Amanda [1 ]
Munz, Jaro [1 ]
Klaus, Jeremias [1 ]
Loebelenz, Laura, I [1 ]
Hoffner, Maximilian Korbinian Michael [1 ]
Hourscht, Cynthia [1 ]
Heverhagen, Johannes T. [1 ,2 ,3 ]
Christe, Andreas [1 ]
Ebner, Lukas [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Diagnost Intervent & Pediat Radiol DIPR, Inselspital, CH-3010 Bern, Switzerland
[2] Univ Bern, Dept BioMed Res, Expt Radiol, Bern, Switzerland
[3] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
关键词
Computer-assisted diagnosis; diagnostic X-ray; lung neoplasm; radiographic phantoms; COMPUTER-AIDED DETECTION; CANCER; CT; CLASSIFICATION; TUBERCULOSIS; IMAGES;
D O I
10.21037/jtd-20-3522
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Despite the decreasing relevance of chest radiography in lung cancer screening, chest radiography is still frequently applied to assess for lung nodules. The aim of the current study was to determine the accuracy of a commercial AI based CAD system for the detection of artificial lung nodules on chest radiograph phantoms and compare the performance to radiologists in training. Methods: Sixty-one anthropomorphic lung phantoms were equipped with 140 randomly deployed artificial lung nodules (5, 8, 10, 12 mm). A random generator chose nodule size and distribution before a two-plane chest X-ray (CXR) of each phantom was performed. Seven blinded radiologists in training (2 fellows, 5 residents) with 2 to 5 years of experience in chest imaging read the CXRs on a PACS-workstation independently. Results of the software were recorded separately. McNemar test was used to compare each radiologist's results to the AI-computer-aided-diagnostic (CAD) software in a per-nodule and a per-phantom approach and Fleiss-Kappa was applied for inter-rater and intra-observer agreements. Results: Five out of seven readers showed a significantly higher accuracy than the AI algorithm. The pooled accuracies of the radiologists in a nodule-based and a phantom-based approach were 0.59 and 0.82 respectively, whereas the AI-CAD showed accuracies of 0.47 and 0.67, respectively. Radiologists' average sensitivity for 10 and 12 mm nodules was 0.80 and dropped to 0.66 for 8 mm (P=0.04) and 0.14 for 5 mm nodules (P<0.001). The radiologists and the algorithm both demonstrated a significant higher sensitivity for peripheral compared to central nodules (0.66 vs. 0.48; P=0.004 and 0.64 vs. 0.094; P=0.025, respectively). Inter-rater agreements were moderate among the radiologists and between radiologists and AI-CAD software (K'=0.58 +/- 0.13 and 0.51 +/- 0.1). Intra-observer agreement was calculated for two readers and was almost perfect for the phantom-based (K'=0.85 +/- 0.05; K'=0.80 +/- 0.02); and substantial to almost perfect for the nodule-based approach (K'=0.83 +/- 0.02; K'=0.78 +/- 0.02). Conclusions: The AI based CAD system as a primary reader acts inferior to radiologists regarding lung nodule detection in chest phantoms. Chest radiography has reasonable accuracy in lung nodule detection if read by a radiologist alone and may be further optimized by an AI based CAD system as a second reader.
引用
收藏
页码:2728 / 2737
页数:10
相关论文
共 46 条
  • [41] Computer-assisted detection of pulmonary nodules:: performance evaluation of an expert knowledge-based detection system in consensus reading with experienced and inexperienced chest radiologists
    Marten, K
    Seyfarth, T
    Auer, F
    Wiener, E
    Grillhösl, A
    Obenauer, S
    Rummeny, EJ
    Engelke, C
    EUROPEAN RADIOLOGY, 2004, 14 (10) : 1930 - 1938
  • [42] Detection of fibrosing interstitial lung disease-suspected chest radiographs using a deep learning-based computer-aided detection system: a retrospective, observational study
    Ukita, Jumpei
    Nishikiori, Hirotaka
    Hirota, Kenichi
    Honda, Seiwa
    Hatanaka, Kiwamu
    Nakamura, Ryoji
    Ikeda, Kimiyuki
    Mori, Yuki
    Asai, Yuichiro
    Chiba, Hirofumi
    Ogaki, Keisuke
    BMJ OPEN, 2024, 14 (01):
  • [43] Evaluating the performance of a deep learning-based computer-aided diagnosis (DL-CAD) system for detecting and characterizing lung nodules: Comparison with the performance of double reading by radiologists
    Li, Li
    Liu, Zhou
    Huang, Hua
    Lin, Meng
    Luo, Dehong
    THORACIC CANCER, 2019, 10 (02) : 183 - 192
  • [44] Lung nodule detection in chest X-rays using synthetic ground-truth data comparing CNN-based diagnosis to human performance
    Schultheiss, Manuel
    Schmette, Philipp
    Bodden, Jannis
    Aichele, Juliane
    Mueller-Leisse, Christina
    Gassert, Felix G.
    Gassert, Florian T.
    Gawlitza, Joshua F.
    Hofmann, Felix C.
    Sasse, Daniel
    von Schacky, Claudio E.
    Ziegelmayer, Sebastian
    De Marco, Fabio
    Renger, Bernhard
    Makowski, Marcus R.
    Pfeiffer, Franz
    Pfeiffer, Daniela
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [45] Lung nodule detection in chest X-rays using synthetic ground-truth data comparing CNN-based diagnosis to human performance
    Manuel Schultheiss
    Philipp Schmette
    Jannis Bodden
    Juliane Aichele
    Christina Müller-Leisse
    Felix G. Gassert
    Florian T. Gassert
    Joshua F. Gawlitza
    Felix C. Hofmann
    Daniel Sasse
    Claudio E. von Schacky
    Sebastian Ziegelmayer
    Fabio De Marco
    Bernhard Renger
    Marcus R. Makowski
    Franz Pfeiffer
    Daniela Pfeiffer
    Scientific Reports, 11
  • [46] Accuracy of two deep learning-based reconstruction methods compared with an adaptive statistical iterative reconstruction method for solid and ground-glass nodule volumetry on low-dose and ultra-low-dose chest computed tomography: A phantom study
    Kim, Cherry
    Kwack, Thomas
    Kim, Wooil
    Cha, Jaehyung
    Yang, Zepa
    Yong, Hwan Seok
    PLOS ONE, 2022, 17 (06):