Performance of an AI based CAD system in solid lung nodule detection on chest phantom radiographs compared to radiology residents and fellow radiologists

被引:11
|
作者
Peters, Alan A. [1 ]
Decasper, Amanda [1 ]
Munz, Jaro [1 ]
Klaus, Jeremias [1 ]
Loebelenz, Laura, I [1 ]
Hoffner, Maximilian Korbinian Michael [1 ]
Hourscht, Cynthia [1 ]
Heverhagen, Johannes T. [1 ,2 ,3 ]
Christe, Andreas [1 ]
Ebner, Lukas [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Diagnost Intervent & Pediat Radiol DIPR, Inselspital, CH-3010 Bern, Switzerland
[2] Univ Bern, Dept BioMed Res, Expt Radiol, Bern, Switzerland
[3] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
关键词
Computer-assisted diagnosis; diagnostic X-ray; lung neoplasm; radiographic phantoms; COMPUTER-AIDED DETECTION; CANCER; CT; CLASSIFICATION; TUBERCULOSIS; IMAGES;
D O I
10.21037/jtd-20-3522
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Despite the decreasing relevance of chest radiography in lung cancer screening, chest radiography is still frequently applied to assess for lung nodules. The aim of the current study was to determine the accuracy of a commercial AI based CAD system for the detection of artificial lung nodules on chest radiograph phantoms and compare the performance to radiologists in training. Methods: Sixty-one anthropomorphic lung phantoms were equipped with 140 randomly deployed artificial lung nodules (5, 8, 10, 12 mm). A random generator chose nodule size and distribution before a two-plane chest X-ray (CXR) of each phantom was performed. Seven blinded radiologists in training (2 fellows, 5 residents) with 2 to 5 years of experience in chest imaging read the CXRs on a PACS-workstation independently. Results of the software were recorded separately. McNemar test was used to compare each radiologist's results to the AI-computer-aided-diagnostic (CAD) software in a per-nodule and a per-phantom approach and Fleiss-Kappa was applied for inter-rater and intra-observer agreements. Results: Five out of seven readers showed a significantly higher accuracy than the AI algorithm. The pooled accuracies of the radiologists in a nodule-based and a phantom-based approach were 0.59 and 0.82 respectively, whereas the AI-CAD showed accuracies of 0.47 and 0.67, respectively. Radiologists' average sensitivity for 10 and 12 mm nodules was 0.80 and dropped to 0.66 for 8 mm (P=0.04) and 0.14 for 5 mm nodules (P<0.001). The radiologists and the algorithm both demonstrated a significant higher sensitivity for peripheral compared to central nodules (0.66 vs. 0.48; P=0.004 and 0.64 vs. 0.094; P=0.025, respectively). Inter-rater agreements were moderate among the radiologists and between radiologists and AI-CAD software (K'=0.58 +/- 0.13 and 0.51 +/- 0.1). Intra-observer agreement was calculated for two readers and was almost perfect for the phantom-based (K'=0.85 +/- 0.05; K'=0.80 +/- 0.02); and substantial to almost perfect for the nodule-based approach (K'=0.83 +/- 0.02; K'=0.78 +/- 0.02). Conclusions: The AI based CAD system as a primary reader acts inferior to radiologists regarding lung nodule detection in chest phantoms. Chest radiography has reasonable accuracy in lung nodule detection if read by a radiologist alone and may be further optimized by an AI based CAD system as a second reader.
引用
收藏
页码:2728 / 2737
页数:10
相关论文
共 46 条
  • [31] A computer-aided diagnosis system for lung nodule detection in chest radiographs using a two-stage classification method based on radial gradient and template matching
    Nagata, Ryoichi
    Kawaguchi, Tsuyoshi
    Miyake, Hidetoshi
    PROCEEDINGS OF THE 2013 6TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2013), VOLS 1 AND 2, 2013, : 80 - 85
  • [32] Effects of Expert-Determined Reference Standards in Evaluating the Diagnostic Performance of a Deep Learning Model: A Malignant Lung Nodule Detection Task on Chest Radiographs
    Huh, Jung Eun
    Lee, Jong Hyuk
    Hwang, Eui Jin
    Park, Chang Min
    KOREAN JOURNAL OF RADIOLOGY, 2023, 24 (02) : 155 - 165
  • [33] A CAD system for nodule detection in low-dose lung CTs based on region growing and a new active contour model
    Bellotti, R.
    De Carlo, F.
    Gargano, G.
    Tangaro, S.
    Cascio, D.
    Catanzariti, E.
    Cerello, P.
    Cheran, S. C.
    Delogu, P.
    De Mitri, I.
    Fulcheri, C.
    Grosso, D.
    Retico, A.
    Squarcia, S.
    Tommasi, E.
    Golosio, Bruno
    MEDICAL PHYSICS, 2007, 34 (12) : 4901 - 4910
  • [34] Performance of AI-based software for pulmonary nodule detection and characterization on chest X-ray and correlation with CT findings: A retrospective study
    Ravind, R.
    Chattoraj, S.
    Shivabasappa, S.
    Singh, A.
    Chamadia, R.
    Sathyamurthy, S.
    Robert, D.
    Jeeson, J.
    Vanpully, N. S.
    Shaikh, S. M. J.
    Bose K, R.
    Nasery, M.
    ANNALS OF ONCOLOGY, 2024, 35 : S1620 - S1620
  • [35] Effect of emphysema on AI software and human reader performance in lung nodule detection from low-dose chest CT (vol 8, 63, 2024)
    Sourlos, Nikos
    Pelgrim, Gertjan
    Wisselink, Hendrik Joost
    Yang, Xiaofei
    de Jonge, Gonda
    Rook, Mieneke
    Prokop, Mathias
    Sidorenkov, Grigory
    van Tuinen, Marcel
    Vliegenthart, Rozemarijn
    van Ooijen, Peter M. A.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [36] Performance of a deep learning-based lung nodule detection system as an alternative reader in a Chinese lung cancer screening program
    Cui, Xiaonan
    Zheng, Sunyi
    Heuvelmans, Marjolein A.
    Du, Yihui
    Sidorenkov, Grigory
    Fan, Shuxuan
    Li, Yanju
    Xie, Yongsheng
    Zhu, Zhongyuan
    Dorrius, Monique D.
    Zhao, Yingru
    Veldhuis, Raymond N. J.
    de Bock, Geertruida H.
    Oudkerk, Matthijs
    van Ooijen, Peter M. A.
    Vliegenthart, Rozemarijn
    Ye, Zhaoxiang
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 146
  • [37] The effects of 3D region-based compression on the performance of an automatic lung nodule detection system
    Odry, BL
    Krishnan, K
    Nadar, M
    Naidich, DP
    Novak, CL
    Marcellin, MW
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 883 - 894
  • [38] Automatic Lung Nodule Detection by a Deep Learning-Based CAD System: The Value of Slab Thickness in the Maximum Intensity Projection Technique
    Zheng, S.
    Cui, X.
    Vonder, M.
    Veldhuis, R.
    Dorrius, M.
    Ye, Z.
    Vliegenthart, R.
    Oudkerk, M.
    Van Ooijen, P.
    JOURNAL OF THORACIC ONCOLOGY, 2021, 16 (03) : S479 - S480
  • [39] Computer-assisted detection of pulmonary nodules: performance evaluation of an expert knowledge-based detection system in consensus reading with experienced and inexperienced chest radiologists
    Katharina Marten
    Tobias Seyfarth
    Florian Auer
    Edzard Wiener
    Andreas Grillhösl
    Silvia Obenauer
    Ernst J. Rummeny
    Christoph Engelke
    European Radiology, 2004, 14 : 1930 - 1938
  • [40] A PERCIST 1.0 based Computer Assisted Detection (CAD) system: Performance compared to an expert reader in the evaluation of breast cancer
    Leal, Jeffrey
    Mhlanga, Joyce
    Chaudhry, Muhammad
    Wahl, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52