Non-invasive characterization of total arterial compliance by simultaneous acquisition of pressure and flow: Advantages of the pulse pressure method

被引:7
|
作者
Carlier, S [1 ]
Segers, P [1 ]
Pasquet, A [1 ]
Armstrong, G [1 ]
Greenberg, NL [1 ]
Stergiopulos, N [1 ]
Marwick, T [1 ]
Thomas, JD [1 ]
机构
[1] Cleveland Clin Fdn, Cleveland, OH 44195 USA
来源
关键词
D O I
10.1109/CIC.1998.731961
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compare three proposed indices of total arterial compliance (Ctot) in normal volunteers (n=9) and patients with coronary artery disease (n=14) using a non-invasive approach (echo-Doppler and carotid tonometry): (I) the pulse pressure method (PPM) (2) the area method (AM) and (3) the stroke volume-to-pulse pressure ratio (SV/PP). The best agreement was found between the PPM and SV/PP. Compliance estimates were lower in the patient group (PPM: 1.2+/-0.4 vs. 1.6+/-0.2; AM: 1.6+/-0.6 vs. 2.8+/-1.3; SV/PP: 1.8+/-0.6 vs. 2.4+/-0.4), being older (64+/-14 vs. 35+/-4) and with known atherosclerosis. The best correlation between compliance and age was found with PPM (r(2)=0.52). AM varied with the chosen computation interval in diastole. These preliminary data describing the very first use of the PPM on non-invasive human recordings suggest that PPM could be a more robust estimator of Ctot than the widely used AM, and that SV/PP could be a reasonable simpler surrogate.
引用
下载
收藏
页码:665 / 668
页数:4
相关论文
共 50 条
  • [41] A non-invasive blood pressure prediction method based on pulse wave feature fusion
    Yan, Jianjun
    Cai, Xianglei
    Zhu, Guangyao
    Guo, Rui
    Yan, Haixia
    Wang, Yiqin
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 74
  • [42] NON-INVASIVE MEASUREMENT OF PULMONARY ARTERIAL-PRESSURE .2. A RADIONUCLIDE METHOD
    BOURGUIGNON, MH
    LEGULUDEC, D
    VALETTE, H
    DAVY, J
    MOTTE, G
    ODDOU, C
    BUCHANAN, JW
    RAYNAUD, C
    SYROTA, A
    WAGNER, HN
    PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (02): : 215 - 225
  • [43] Non-Invasive Estimation of Pulse Pressure in HeartMate 3 Patients
    Gaudig, A.
    Pinsino, A.
    Braghieri, L.
    Wang, Y.
    Mondellini, G. M.
    Hastie, J. M.
    Panzer, O.
    Takeda, K.
    Naka, Y.
    Sayer, G. T.
    Uriel, N.
    Yuzefpolskaya, M.
    Colombo, P. C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S99 - S100
  • [44] A new indicator for non-invasive arterial blood pressure measurement
    Regueiro-Gomez, A
    Pallas-Areny, R
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 117 - 118
  • [46] Early Detection of Hemorrhage via Central Pulse Pressure Derived from a Non-Invasive Peripheral Arterial Blood Pressure Waveform
    Zhang, Guanqun
    Ryan, Kathy L.
    Rickards, Caroline A.
    Convertino, Victor A.
    Mukkamala, Ramakrishna
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3116 - 3119
  • [47] NON-INVASIVE REGISTRATION OF THE ARTERIAL-PRESSURE PULSE WAVEFORM USING HIGH FIDELITY APPLANATION TONOMETRY
    AVOLIO, A
    KELLY, R
    HAYWARD, D
    WINTER, D
    OROURKE, M
    FASEB JOURNAL, 1988, 2 (04): : A316 - A316
  • [48] Non-invasive assessment of local arterial pulse pressure: comparison of applanation tonometry and echo-tracking
    Van Bortel, LM
    Balkestein, EJ
    van der Heijden-Spek, JJ
    Vanmolkot, FH
    Staessen, JA
    Kragten, JA
    Vredeveld, JW
    Safar, ME
    Boudier, HAS
    Hoeks, AP
    JOURNAL OF HYPERTENSION, 2001, 19 (06) : 1037 - 1044
  • [49] Antenatal central aortic systolic pressure norms from non-invasive arterial pulse waveform analysis
    Jonathan, H. Y.
    Ju, N. Q.
    Hong, Y. S.
    Kenneth, K.
    Hian, T. K.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2016, 123 : 89 - 89
  • [50] A new method for non-invasive intracranial pressure monitoring
    Russell, D
    Paulat, K
    Maur, UM
    Brucher, R
    STROKE, 2004, 35 (06) : E231 - E231