Non-invasive characterization of total arterial compliance by simultaneous acquisition of pressure and flow: Advantages of the pulse pressure method

被引:7
|
作者
Carlier, S [1 ]
Segers, P [1 ]
Pasquet, A [1 ]
Armstrong, G [1 ]
Greenberg, NL [1 ]
Stergiopulos, N [1 ]
Marwick, T [1 ]
Thomas, JD [1 ]
机构
[1] Cleveland Clin Fdn, Cleveland, OH 44195 USA
来源
关键词
D O I
10.1109/CIC.1998.731961
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compare three proposed indices of total arterial compliance (Ctot) in normal volunteers (n=9) and patients with coronary artery disease (n=14) using a non-invasive approach (echo-Doppler and carotid tonometry): (I) the pulse pressure method (PPM) (2) the area method (AM) and (3) the stroke volume-to-pulse pressure ratio (SV/PP). The best agreement was found between the PPM and SV/PP. Compliance estimates were lower in the patient group (PPM: 1.2+/-0.4 vs. 1.6+/-0.2; AM: 1.6+/-0.6 vs. 2.8+/-1.3; SV/PP: 1.8+/-0.6 vs. 2.4+/-0.4), being older (64+/-14 vs. 35+/-4) and with known atherosclerosis. The best correlation between compliance and age was found with PPM (r(2)=0.52). AM varied with the chosen computation interval in diastole. These preliminary data describing the very first use of the PPM on non-invasive human recordings suggest that PPM could be a more robust estimator of Ctot than the widely used AM, and that SV/PP could be a reasonable simpler surrogate.
引用
下载
收藏
页码:665 / 668
页数:4
相关论文
共 50 条
  • [21] Pulse pressure vs. total arterial compliance as a marker of arterial health
    Haluska, BA
    Jeffriess, L
    Fathi, RB
    Mottram, PM
    Carlier, SG
    Marwick, TH
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2005, 35 (07) : 438 - 443
  • [22] Techniques for Non-Invasive Monitoring of Arterial Blood Pressure
    Meidert, Agnes S.
    Saugel, Bernd
    FRONTIERS IN MEDICINE, 2018, 4
  • [23] An Investigation of Pulse Transit Time as a Non-Invasive Blood Pressure Measurement Method
    McCarthy, B. M.
    O'Flynn, B.
    Mathewson, A.
    SENSORS & THEIR APPLICATIONS XVI, 2011, 307
  • [24] A new, simple, and accurate method for non-invasive estimation of pulmonary arterial pressure
    Xu, J
    Durand, LG
    Pibarot, P
    HEART, 2002, 88 (01) : 76 - 80
  • [25] A comparison of invasive and non-invasive arterial blood pressure measurements in the neonate
    Shea, J. E. O'
    Dempsey, E. M.
    ACTA PAEDIATRICA, 2007, 96 : 190 - 191
  • [26] Non-invasive method for monitoring intracranial pressure
    Russell, D.
    Paulat, K.
    Maur, U. M.
    Brucher, R.
    EUROPEAN JOURNAL OF NEUROLOGY, 2004, 11 : 289 - 289
  • [27] A COMPARISON OF INVASIVE AND NON-INVASIVE ARTERIAL BLOOD PRESSURE MEASUREMENTS IN THE NEONATE
    O'Shea, J.
    Dempsey, E.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2010, 179 : S174 - S174
  • [28] Relating external compressing pressure to mean arterial pressure in non-invasive blood pressure measurements
    Chin, K.Y.
    Panerai, R.B.
    Journal of Medical Engineering and Technology, 2015, 39 (01): : 79 - 85
  • [29] Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease
    Bogert, L. W. J.
    Wesseling, K. H.
    Schraa, O.
    Van Lieshout, E. J.
    de Mol, B. A. J. M.
    van Goudoever, J.
    Westerhof, B. E.
    van Lieshout, J. J.
    ANAESTHESIA, 2010, 65 (11) : 1119 - 1125
  • [30] A novel approach for non-invasive measurement of mean arterial pressure using pulse transit time
    V. Prabhu
    P. G. Kuppusamy
    A. Karthikeyan
    M. Sucharitha
    Multimedia Tools and Applications, 2020, 79 : 3775 - 3789