Non-invasive characterization of total arterial compliance by simultaneous acquisition of pressure and flow: Advantages of the pulse pressure method

被引:7
|
作者
Carlier, S [1 ]
Segers, P [1 ]
Pasquet, A [1 ]
Armstrong, G [1 ]
Greenberg, NL [1 ]
Stergiopulos, N [1 ]
Marwick, T [1 ]
Thomas, JD [1 ]
机构
[1] Cleveland Clin Fdn, Cleveland, OH 44195 USA
来源
关键词
D O I
10.1109/CIC.1998.731961
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compare three proposed indices of total arterial compliance (Ctot) in normal volunteers (n=9) and patients with coronary artery disease (n=14) using a non-invasive approach (echo-Doppler and carotid tonometry): (I) the pulse pressure method (PPM) (2) the area method (AM) and (3) the stroke volume-to-pulse pressure ratio (SV/PP). The best agreement was found between the PPM and SV/PP. Compliance estimates were lower in the patient group (PPM: 1.2+/-0.4 vs. 1.6+/-0.2; AM: 1.6+/-0.6 vs. 2.8+/-1.3; SV/PP: 1.8+/-0.6 vs. 2.4+/-0.4), being older (64+/-14 vs. 35+/-4) and with known atherosclerosis. The best correlation between compliance and age was found with PPM (r(2)=0.52). AM varied with the chosen computation interval in diastole. These preliminary data describing the very first use of the PPM on non-invasive human recordings suggest that PPM could be a more robust estimator of Ctot than the widely used AM, and that SV/PP could be a reasonable simpler surrogate.
引用
下载
收藏
页码:665 / 668
页数:4
相关论文
共 50 条
  • [1] A non-invasive pulse pressure method for the estimation of total arterial compliance
    Segers, P
    Stergiopulos, N
    Verdonck, P
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 171 - 174
  • [2] The pulse pressure method for non-invasive evaluation of total arterial compliance
    Carlier, S
    Segers, P
    De Backer, T
    Stergiopoulos, N
    Thomas, J
    JOURNAL OF HYPERTENSION, 2000, 18 : S197 - S197
  • [3] Non-invasive measurement of arterial pressure-dependent compliance
    Liu, Changchun
    Xin, Sun
    Liu, Chengyu
    Gu, Jason J.
    Yu, Mengsun
    2007 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-3, 2007, : 590 - 593
  • [4] NON-INVASIVE, CONTINUOUS, PULSE PRESSURE MONITORING METHOD
    Kuwahara, Makiko
    Yavari, Ehsan
    Boric-Lubecke, Olga
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6574 - 6577
  • [5] A new non-invasive method using pulse oximetry for the assessment of arterial toe pressure
    Samuelsson, P
    Blohme, G
    Fowelin, J
    Eriksson, JW
    CLINICAL PHYSIOLOGY, 1996, 16 (04): : 463 - 467
  • [6] Use of pulse pressure method for estimating total arterial compliance in vivo
    Stergiopulos, N
    Segers, P
    Westerhof, N
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 276 (02): : H424 - H428
  • [7] NON-INVASIVE PRESSURE PULSE RECORDER
    JAFFRIN, MY
    RAO, S
    RAINES, JK
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (05): : 721 - &
  • [8] Non-invasive measurement of arterial pulse waves of a GMI pressure transducer
    Louzada, D. Ramos
    Monteiro, E. Costa
    Gusmao, L. A. P.
    Barbosa, C. Hall
    IV LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING 2007, BIOENGINEERING SOLUTIONS FOR LATIN AMERICA HEALTH, VOLS 1 AND 2, 2008, 18 (1,2): : 436 - +
  • [9] A contribution from new technologies: towards a non-invasive method for measuring arterial pulse pressure?
    Gonzalez-Estevez, M.
    Robin, E.
    Vallet, B.
    REANIMATION, 2012, 21 (02): : 142 - 148
  • [10] Non-invasive monitoring of intracranial pressure and compliance
    Paulat, K
    Brucher, R
    Russell, D
    STROKE, 2001, 32 (01) : 371 - 371